1. A compound-wound generator terminal connection box contains terminal leads a. F1, F2 and A1, A2. b. S1, S2 and F1, F2. c. S1, S2 and A1, A2. d. S1, S2, F1, F2, and A1, A2. 2. The series winding must be large enough to carry a. the total magnetic flux. b. a 300% overload. c. full line current. d. full line voltage. 3. Select the type of generator that may be used for loads quite distant from the generator. a. overcompounded b. flat compounded c. undercompounded d. differential compounded 4. The normal voltage of a compound generator is changed by adjusting the a. series field shunt. b. brush setting. c. shunt field rheostat. d. equalizer.

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.16MCQ: In developing per-unit circuits of systems such as the one shown in Figure 3.10. when moving across...
icon
Related questions
Question
100%

Select the correct answer for each of the following statements

Book Source: Electricity 3 | 10th Edition ISBN-13:9781111646738 ISBN:1111646732 Authors:Jeffrey J. Keljik

Unit 4: Compound-Wound
DC Generator
Select the correct answer for each of the following statements
Book Source: Electricity 3 | 10th Edition
ISBN-13:9781111646738ISBN:1111646732Authors:Jeffrey J. Keliik
1. A compound-wound generator terminal connection box contains terminal leads
a. F1, F2 and A1, A2.
b. S1, S2 and F1, F2.
c. S1, S2 and A1, A2.
d. S1, S2, F1, F2, and A1, A2.
2. The series winding must be large enough to carry
a. the total magnetic flux.
b. a 300% overload.
c. full line current.
d. full line voltage.
3. Select the type of generator that may be used for loads quite distant from the
generator.
a. overcompounded
b. flat compounded
c. undercompounded
d. differential compounded
4. The normal voltage of a compound generator is changed by adjusting the
a. series field shunt.
b. brush setting.
c. shunt field rheostat.
d. equalizer.
Transcribed Image Text:Unit 4: Compound-Wound DC Generator Select the correct answer for each of the following statements Book Source: Electricity 3 | 10th Edition ISBN-13:9781111646738ISBN:1111646732Authors:Jeffrey J. Keliik 1. A compound-wound generator terminal connection box contains terminal leads a. F1, F2 and A1, A2. b. S1, S2 and F1, F2. c. S1, S2 and A1, A2. d. S1, S2, F1, F2, and A1, A2. 2. The series winding must be large enough to carry a. the total magnetic flux. b. a 300% overload. c. full line current. d. full line voltage. 3. Select the type of generator that may be used for loads quite distant from the generator. a. overcompounded b. flat compounded c. undercompounded d. differential compounded 4. The normal voltage of a compound generator is changed by adjusting the a. series field shunt. b. brush setting. c. shunt field rheostat. d. equalizer.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 3 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning