Question
please solve these 2 questions handwritten step by step solution to make me understanding well thank you
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 6 images
Knowledge Booster
Similar questions
- The conductor of a single-phase 60-Hz line is a solid round aluminum wire having a diameter of 0.412 cm. The conductor spacing is 3 m. Determine the inductance of the line in millinery’s per mile. How much of the inductance is due to internal flux linkages? Assume skin effect is negligible.arrow_forwardThe conductor of a single-phase 60-Hz line is a solid round aluminum wire having a diameter of 0.412 cm. The conductor spacing is 3 m. Determiņe the inductance of the line in millihenrys per mile. How much of the inductance is due to internal flux linkages? Assume skin effect is negligible.arrow_forwardDevelop a small-scale equivalent transmission line pi model (per phase) of the transmission lines with the specification given in table 1. The conductors are placed with a flat horizontal spacing of 7.25 meters. Consider that the load connected against the line 125MW at 0.85 lagging power factor. You are required to develop an equivalent model for a maximum 220V (RMS) sending and receiving end voltage and a maximum of 5A load current. Sr. NTDC Transmission Line Length Conductor No. Туре 220 kV DG Khan-Loralai Transmission Line (227 km) 227km Pheasant TABLE AJ Electrical characteristics of bare aluminum conductors steel-relnforced (ACSR)+ Reniertance Reactance per conductor 1-ft apacing. 60 Ha Ae, 60 Ha Capaitive Aluminum ares, emil Layers of Outaide aluminum diameter, in a/1,000 ft soC, D/ml GMR Induetive Stranding AL/8t De, 20°C. 20C, a/mi Code word D. t Ma-mi Waswing Partridge Ostrieh Merlin Linnet Oriole Chickndee Ibin Pelienn Flicker Hawk 266,800 206,800 300,000 336, 400 336.400…arrow_forward
- answer it i will ratearrow_forward2. A three-phase 60-hz transmission line has its conductors arranged in a triangular formation so that two of the distances between conductors are 20 ft and the third is 40 ft. The conductors are ACSR Rook. Determine the capacitance to neutral in microfarads per mile and the capacitive reactance to neutral in ohm-miles. If the line is 115 mi long, find the capacitance to neutral and capacitive reactance of the line.arrow_forwardA three-phase, 60-Hz, untransposed transmission line runs in parallel with a telephone line for 20 km. The power line carries a balanced three-phase rms current of Ia = 3202 – 240°A. The line configuration is as shown in figure. Assume zero current flows in the ungrounded telephone wires. Find the magnitude of the voltage induced in the telephone line. = 32020°A, Ī, = 3204–120°A, and a 4 m 4 m 5 m d G2 mOarrow_forward
- The VSWR on an 50-Ohm transmission line is 5. The distance between successive voltageminima is 80 cm while the distance from the load to the first minimum is 30 cm. What are thereflection coefficient and load impedancearrow_forwardTransmission line conductance is usually neglected in power system studies. True Falsearrow_forward1) A 60-Hz, ...-km, three-phase overhead transmission line has a series impedance z = 0.8431L79.04 ohm/km and a shunt admittance y = 5.105 × 106 L90 S/km. The load at the receiving end is 125 MW at unity power factor and at 215 KVLL. Determine the voltage, current, real and reactive power at the sending end and the percent voltage regulation of the line for nominal pi network. (Please determine the length of the transmission line within the specified limits: 150-220 km. By considering the length value you determined yourself, solve the question.)arrow_forward
- 4/ Which parameter is neglected or ignored in Short Transmission Lines? A. SHUNT CAPACITANCE ONLY B. SERIES CONDUCTANCE AND SHUNT CAPACITANCE C. SHUNT CONDUCTANCE AND SHUNT CAPACITANCE D. SHUNT CONDUCTANCE ONLYarrow_forwardA three-phase 60-Hz transmission line has its conductors arranged in a triangular formationso that two of the distances between conductors are 25 ft. and the third distance is 42 ft.The conductors are ACSR Osprey. Determine the inductance and inductive reactance perphase per mile.arrow_forwardA 220 kV, three phase transmission line is 50 km long. The resistance per phase is r 2 per km and the inductance per phase is L mH per km. The shunt capacitance is negligible. If the line supplies a three-phase load of 229 MVA at 0.8 power factor lagging at 220 kV with an efficiency of 97.13% and a voltage regulation of 4.7581%. Use the short line model to find the line resistance and inductance of the line.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning