1. A lead pipe has 2 cm inside diameter, 3 cm outer diameter, length of 130 cm. Liquid water at 4°C flows through the pipe with a bulk velocity of 2.50 km/hr. Air is blown around the outside of the pipe at 20 deg C. The inside wall of the said pipe has a temperature of 8 deg Celsius. Find: Overall heat coefficient (U) based on outside surface area b. Prandtl (Pr) and Reynolds (Re) numbers based on classification of flow а.
Q: ater flowing at 0.1 kg/s through a thin-walled 50-mm diameter pipe is cooled from 400 K to 300 K.…
A: Given data: The water flow rate is m=0.1 kg/s˙ The diameter of the pipe is D=50 mm=0.05 m The…
Q: The liquid food is heated in a tubular heat exchanger. The inside pipe wall temperature is 110 °C.…
A: Given data as per question T1=1100Cinternal diameter of pipe =50 mmflow rate =0.7 kgsInitial…
Q: Water is to be heated from 20 to 60 0C as it flows through a thick-walled tube having inner and…
A: a) Write the expression for the rate of heating. Here, q̇ represents the heat flux, A represents…
Q: A liquid metal flows at the rate of 4kg/s through a constant heat flux 6cm inner diameter tube in a…
A: Given- Diameter (d) = 6 cm = 0.06 m Mass flow rate (m) = 4 kg/s ρ = 7700 kg/m3 , Y =…
Q: A flat plate measuring 60cm by 60cm is exposed on one side to 40°C water flowing at 3.5 m/s parallel…
A: Density of water = 1000 kg /m3 K= 0.6294 w/(m-k) viscosity = .658*10-6 m2/ s
Q: Hot water is transferred through a stainless steel pipe of 0.06m inside diameter and 5m length. The…
A:
Q: Furnace walls are lined by 3 layers: firebrick with a thickness of 6 in (k=0.95 Btu/h.ft. F),…
A:
Q: Air at 10 atm and 77 C flows in a duct of rectangular cross section, 20 cm by 10 cm, at a rate of…
A: (a) Calculate the volume flow rate of the air. P=ρRT10×1.0125×105=ρ287350ρ=10.08…
Q: T0 2-Water is heated as it flows through a square duct with side a=2 cm and the mean velocity…
A: Given, Heat flux, q"=2000 W/m2 The side of the square, a=2 cm=2×10-2 m The mean velocity, um=3.2…
Q: 8. A lead pipe has 2 cm inside diameter, 3 cm outer diameter, length of 130 cm. Liquid water at 4°C…
A:
Q: 1. Calculate the maximum linear heat rate in a rod if the bulk coolant temperature is 280°C and the…
A: Coolant temperature = 280° C Centerline temperature = 2800 ° C Now we can calculate by
Q: Air is flowing through a thick walled copper pipe that can be considered to be isothermal at 450…
A:
Q: Heat Transfer with a Liquid Metal. The liquid metal bismuth at a flow rate of 2.00 kg/s enters a…
A: Given Mass flow rate = 2 kg/s Internal diameter = 35 mm Tube surface temperature offset = 25 C…
Q: The Air on 1 ATM on T. = 250 K And the free flow rate is 30 meters It flows across a diameter…
A:
Q: Hot water at 98°C flows through a 2-in schedule 40 horizontal steel pipe [k 54 W/m C] and is exposed…
A: Given2 in schedule 40 horizontal steel pipek=54 w/m °CT=98°CT00=20°Cwater velocity(v) =25 cm/s =0.25…
Q: Q) A refrigerant at |-40^ C flows into a copper pipe (400 W/mK) of 10 mm ID and 14 mm OD. A 40 mm…
A: To determine the heat transfer per unit length and the amount of refrigerant evaporated.
Q: 2. In an electric tea kettle filled with water, the bottom surface temperature is at 130 °C and has…
A: Given:Ts=130°Cd=5 in =0.127 mStandard atmospheric conditios:Temperature of water, Tw=20°CCp=4.186…
Q: Q2- A long aluminum wire of diameter 3 mm is extruded at a temperature of 370°C. The wire is…
A: Wire diameter = 3mm Wire temperature = 370 C Air temperature = 30 C Air velocity = 6 m/s
Q: 3. A 3 in O.D. aluminum tube (k=133 BTU/h ft°F) has 16 longitudinal fins spaced around its outside…
A: Give data: The outer diameter of the tube, do=3 in. The thermal conductivity of aluminum, k=133…
Q: Water enters a tube at 29°C with a flow rate of 460 kg/h. The rate of heat transfer from the tube…
A: Solution to first three sub-parts as per our company policy:
Q: Figure below shows the heat flux flowing across the area, Ay, creating temperature at the surfaces…
A:
Q: Water with an average temperature of 35 °C flows in a pipe of 3 mm diameter and 2 m length. The pipe…
A: Write the values of kinematic viscosity, Prandtl number, and Thermal conductivity of water at 35oC…
Q: Heat transter by convection Example( 1) Air at 2 atm and 200 c° is heated as it flow through a tube…
A: given dataTin=200°CD=2.54cmV=10m/s∆T=20°CL=3mρ=1.493 kg/m3cp=1.025 kj/kg°Ck=0.0386…
Q: Hot water (cp=D4.18 kJ/kg.K, m = mm, Length = 93 cm, thickness = 1.0 mm, k, outer surface is 204…
A: Specific heat of water, CP=4.18 KJ/kg.KMass flow rate of water,m˙=2.8kg/minInner diameter of tube,…
Q: 8. A lead pipe has 2 cm inside diameter, 3 cm outer diameter, length of 130 cm. Liquid water at 4°C…
A:
Q: Water at 100°C flows in a aluminum pipe with a distance 10m (0.1m inside diameter, 0.02m thick, k=…
A: 
Q: 17.Find the heat flow during 5.0 h through a glass window of thickness 0.20 in. with an area of 40…
A: We have to determine the heat flow
Q: Hot fluid "C= 2562 J/kg.k, Pr=51.3, µu = 5.22E-3 Pa.s, k = 0.260 W/m.K" flows at 1.3 kg/min inside a…
A: Given:Cp=2562 J/KgKPr=51.3μ=5.22E-3 Pa.sk=0.260 W/mKm=1.3 Kg/minTs=23°CTo=35°C∆T=45°CTi=45+35=80°C
Q: A spherical shaped vessel of 1.2 m diameter is 100 mm thick. Find the rate of heat leakage, if the…
A:
Q: Tout=? V(m/s) D=0.1m air Air at (3.10x10^2) K is entering in a circular pipe at 101325 Pa as shown…
A: Using ideal gas equation, P=rho*R*T Put all known values 101325=rho*287*310 rho(density)=1.14kg/m^3…
Q: A 5 meter copper tube is heated externally to 100 °C. Air heated by passing it through the 40mm…
A:
Q: Using a 130 cm- long lead pipe with 2 cm inside diameter, a liquid water is transferred at 4 degrees…
A: given; ⇒length of pipe (L)=130cm=1.30m⇒inside diamter(d1)=2cm=0.02m⇒outside…
Q: Water (C, = 4180 J/kg-K) enters a 4-cm-diameter tube at 15°C at a rate of 0.06 kg/s. The tube is…
A: As per given question we have to define lengths of tube.
Q: An electric heater heats the inner tube walls of a concentric tube annulus at a rate of 2000 W/m.…
A: Given Data Rate of heat transfer is : q'=2000 W/m Inner diameter is : di=25 mm Outer diameter is :…
Q: Hot water (cp=4.18 kJ/kg.K, m = 2.8 kg/min) flows inside a tube (inner diameter = 9 mm, Length = 93…
A: From the given data, heat flux on the tube outer surface is (q") = 204×103 W/m2. Touter = 93 oC and…
Q: 04/Liquid ammonia at 10°C and I atm flows across a horizontal cylinder at a velocity of'5 m/s. The…
A: Given, Pipe diameter, D=2.5cm=0.025m Pipe length, L=125cm=0.125m Surface temperature, Ts=30°C…
Q: A long, bare, 0.20 mm diameter nichrome wire experiences the cross flow of 300 K nitrogen at a…
A:
Q: Air is flowing ithrough a thick walled copper pipe that can be considered to be isothermal at 450…
A:
Q: is exposed to cooler air at 30 °C with h = 60 W²/m °C. Calculate the heat loss from the tube to the…
A: d1=5cm=0.05mr1=0.025md2=7.6cm=0.076mr2=0.025mRadius,r3=r2+Insulation…
Q: Water at 25°C flows across a horizontal copper tube 1.5cm outer diameter with a velocity of 2 mi/s.…
A: In heat transfer analysis, the rate of change of state is evaluated by calculating the rate of heat…
Q: Example: Steam in a heating system flows through tubes whose outer diameter isD1=3 cm and whose…
A:
Q: Water flow in steel pipe at a temperature of 50o C as shown in the figure. The pipe is wrapped with…
A:
Q: A type 316 stainless steel pipe has a 6 cm inside diameter and an 8 cm outside diameter with a 2 mm…
A: The Answer is in Below step
Q: Air at 20 °C blows over a hot plate 50 by 75 cm maintained at 250 °C. The convection heat-transfer…
A:
Q: 24 A fluid at °C flows (by forced mode) over the upper surface of a flat plate whose temperature is…
A:
Q: Hot fluid "C,= 2562 J/kg.k, Pr 51.3, µ = 5.22E-3 Pa.s,k 0.260 W/m.K" flows at 0.9 kg/min inside a…
A:
Q: Refrigerant-134a is being transported at 0.08 kg/s through a Teflon tube of inside diameter D = 20…
A:
Q: Water at 25°C flows across a horizontal copper tube 1.5cm outer diameter with a velocity of 2 mi/s.…
A: "Since you have asked multiple questions, we will solve the first question for you. If you want any…
Step by step
Solved in 3 steps with 3 images
- Example: A 1.0 kw heater is Constructed ofaglass plte with an electrically condcting film which produčes' a Constant hent flux . The plate is 60x 60 cm and placed in an air sebeetote stream at 27c ,d atm with Uo=5 m/s. Calculate the average temp. difference along the plate, and the difference at the trailing edge.K spherical shaped vessel of 1.2 m diameter is 100 mm thick. Find the rate of heat leakage, if the temperature difference between the inner and outer surfaces is 200° C. Thermal conductivity of material is 0.3 kJ /mh°C.consider a flow of water in a cylinder maintained at constant temperature of hundred degree Celsius the diameter of the cylinder is 15 and the length of the tube is 6 metre the inlet and outlet temperature of the water is TI equal to 15 degree Celsius and equal 57 degrees celsius find the average heat transfer Coefficient associated with the flow of water mass flow rate is 2.25 kilogram per second and cp=4.178KJ/aKg.K
- What is the formula to solve h1 and h2 (heat transfer coefficient)here? h1 (water) h2 (air).Water at a temperature of 20 oC with a mass flow rate of 0.015 kg/s enters the pipe 2.5 cm in diameter with a uniform surface temperature of 90 oC. a) Determine the length of the thermal inlet region, Lt.b) If it is assumed that the flow is hydrodynamically and thermally formed, calculate the convection heat transfer coefficient and the length of the pipe required to heat the water to 70 oC.c) What is the rate of heat transfer to the water?d) Calculate the friction factor and pressure drop.(B) Air is flowing through a thick walled copper pipe that can be considered to be isothermal at 450 degrees C Inner diameter of the pipe is 3cm and 0 9m inng Air enters at 30 degrees C and exit buik temperature is 95 degrees C. if the length is now doubled assuming air mass flow rate and heat transfer coefficient remain the same in both iengths what is the new bulk temperature at the exit?
- You are designing a pin-style heatsink for forced cooling of an IC. A small fan blows RT air into the heatsink at about 2.3 ? ? . The aluminum pins are 2mm in diameter and have a constant surface temperature of 120°?. The heatsink is 100mm x 100mm and the pins have an inline arrangement with a transverse pitch of 4mm and a longitudinal pitch of 6mm. What is the total heat dissipation of this heatsink? The pins are 30mm high. Note RT=25 celsiusProblem 3: RT Air is flowing over an aluminum pipe (20mm OD, 5mm ID) at 6-. The pipe has 10mm thick fiberglass insulation on it. The pipe is carrying a hot air supply Thair 80°C for use in a chemical m3 process at a rate of Qhair 0.04 What is the heat rate from the hot air to the ambient air?Using a 130 cm- long lead pipe with 2 cm inside diameter, a liquid water is transferred at 4 degrees Celsius. Its outside diameter measures 3 cm and the temperature of air outside is 20-deg C. The inside wall of the said pipe has a temperature of 8 degrees Celsius. Solve for: Outside area as basis, find (U) overall heat transfer coefficient
- Water going into a pipe with a tempeture of T1 and going out T2 . ambient tempeture is T0. flow rate q. Develop an expression for T2 ( based on heat transfer) Length of the pipe Lh0 - convective heat transfer coefficient of the airhW -convective heat transfer coefficient of the waterk- pipe thermal conductivity (W/m·K)d – pipe diameter Use any other varilable that you need and can be found online easily .A steam condenser is made of brass tubes,in., 14 gage. There are 150 tubes per pass. The cooling water flows at the rate of 1.52 m/s, entering at 25°C and leaving at 50°C. The condensing heat transfer coefficient is known to be 10,200 W/m²-°C and the inside tube surface coefficient is 6800 W/m²-°C. Steam is being condensed at 77°C. The tubes are not to exceed 3 m in length. Find the number of tube passes and the length of the tubes.A thick-walled cylinder tubing of hard rubber having an inside radius of 20mm is being used as temporary cooling coil in a bath. Ice water is flowing rapidly through inside tube and the inside wall temperature is 274.9K. The outside surface temperature is 297.1K. A total of 14.65W must be removed from the bath by cooling coil. How many m of tubing are required?