Hot air for a large scale drying operation is to be produced by routing the air over a tube bank, while products of combustion are routed through the tubes. The surface area of the cross-flow heat exchanger is A = 25 m², and for the proposed operating conditions, the manufacturer specifies and overall heat transfer coefficient of U = 35 W/(m²K). The air and the combustion gases may each be assumed to have a specific heat of cp = 1040 J/(kg K). Consider conditions for which combustion gases flowing at 1 kg/s enter the heat exchanger at 800 K, while air at 5 kg/s has an inlet temperature of 300 K. (a) What are the air and gas outlet temperatures? .

Principles of Heat Transfer (Activate Learning with these NEW titles from Engineering!)
8th Edition
ISBN:9781305387102
Author:Kreith, Frank; Manglik, Raj M.
Publisher:Kreith, Frank; Manglik, Raj M.
Chapter10: Heat Exchangers
Section: Chapter Questions
Problem 10.36P
icon
Related questions
Question
Hot air for a large scale drying operation is to be produced by routing the air over a tube bank,
while products of combustion are routed through the tubes. The surface area of the cross-flow
heat exchanger is A = 25 m², and for the proposed operating conditions, the manufacturer
specifies and overall heat transfer coefficient of U = 35 W/(m²K). The air and the combustion
gases may each be assumed to have a specific heat of cp = 1040 J/(kg K). Consider conditions
for which combustion gases flowing at 1 kg/s enter the heat exchanger at 800 K, while air at 5
kg/s has an inlet temperature of 300 K.
(a) What are the air and gas outlet temperatures?
(b) Explore the effect of changes in surface area and heat transfer coefficient on the air
outlet temperature for UA values from 500 to 2500 W/K. Discuss the implications
and back up the discussion with an appropriate plot.
Transcribed Image Text:Hot air for a large scale drying operation is to be produced by routing the air over a tube bank, while products of combustion are routed through the tubes. The surface area of the cross-flow heat exchanger is A = 25 m², and for the proposed operating conditions, the manufacturer specifies and overall heat transfer coefficient of U = 35 W/(m²K). The air and the combustion gases may each be assumed to have a specific heat of cp = 1040 J/(kg K). Consider conditions for which combustion gases flowing at 1 kg/s enter the heat exchanger at 800 K, while air at 5 kg/s has an inlet temperature of 300 K. (a) What are the air and gas outlet temperatures? (b) Explore the effect of changes in surface area and heat transfer coefficient on the air outlet temperature for UA values from 500 to 2500 W/K. Discuss the implications and back up the discussion with an appropriate plot.
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 5 steps with 23 images

Blurred answer
Knowledge Booster
Heat Exchangers
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.
Similar questions
Recommended textbooks for you
Principles of Heat Transfer (Activate Learning wi…
Principles of Heat Transfer (Activate Learning wi…
Mechanical Engineering
ISBN:
9781305387102
Author:
Kreith, Frank; Manglik, Raj M.
Publisher:
Cengage Learning
Refrigeration and Air Conditioning Technology (Mi…
Refrigeration and Air Conditioning Technology (Mi…
Mechanical Engineering
ISBN:
9781305578296
Author:
John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:
Cengage Learning