Block Parameters: Linear Transformer Linear Transfomer (mask) (link) Implements a three windings linear transformer. Click the Apply or the OK button after a change to the Units popup to confirm the conversion of parameters. Parameters Units SI Nominal power and frequency [Pn(VA) fn(Hz)]: [ 250e6 50 ] Winding 1 parameters [V1(Vrms) R1(ohm) L1(H)]: [220 4.3218 0.45856] Winding 2 parameters [V2(Vrms) R2(ohm) L2(H)]: [110 0.7938 0.084225] O Three windings transformer RN Winding 3 parameters [V3(Vrms) R3(ohm) L3(H)]: [3.15e+05 0.7938 0.084225] RA Magnetization resistance and inductance [Rm(ohm) Lm(H)]: [1.0805e+06 2866] Measurements None OK Cancel Help Apply

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.14P: A single-phase 50-kVA,2400/240-volt,60-Hz distribution transformer is used as a step-down...
icon
Related questions
Question
Find the number of turns n1 and n2 utilising the values given in this block parameter for single phase transformer under open circuit test
Block Parameters: Linear Transformer
Linear Transformer (mask) (link)
Implements a three windings linear transformer.
Click the Apply or the OK button after a change to the Units popup
to confirm the conversion of parameters.
Parameters
Units SI
Nominal power and frequency [Pn(VA) fn(Hz)]:
250e6 50 ]
Winding 1 parameters [V1(Vrms) R1(ohm) L1(H)]:
[220 4.3218 0.45856]
Winding 2 parameters [V2(Vrms) R2(ohm) L2(H)]:
[110 0.7938 0.084225]
O Three windings transformer
Winding 3 parameters [V3(Vrms) R3(ohm) L3(H)]:
[3.15e+05 0.7938 0.084225]
RA Magnetization resistance and inductance [Rm(ohm) Lm(H)]:
[1.0805e+06 2866]
Measurements None
OK
Cancel
Help
Apply
100 p
Activate W
Go to Settings
View 4 warnings
87%
Transcribed Image Text:Block Parameters: Linear Transformer Linear Transformer (mask) (link) Implements a three windings linear transformer. Click the Apply or the OK button after a change to the Units popup to confirm the conversion of parameters. Parameters Units SI Nominal power and frequency [Pn(VA) fn(Hz)]: 250e6 50 ] Winding 1 parameters [V1(Vrms) R1(ohm) L1(H)]: [220 4.3218 0.45856] Winding 2 parameters [V2(Vrms) R2(ohm) L2(H)]: [110 0.7938 0.084225] O Three windings transformer Winding 3 parameters [V3(Vrms) R3(ohm) L3(H)]: [3.15e+05 0.7938 0.084225] RA Magnetization resistance and inductance [Rm(ohm) Lm(H)]: [1.0805e+06 2866] Measurements None OK Cancel Help Apply 100 p Activate W Go to Settings View 4 warnings 87%
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Three Phase Transformer
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electric Motor Control
Electric Motor Control
Electrical Engineering
ISBN:
9781133702818
Author:
Herman
Publisher:
CENGAGE L