N N. I + + V. Z, VL (a) If VL = 20-N resistor, I, = 0.05 A, and N, = 50, find the number of turns in the primary circuit of the 240 V, Z, %3D transformer above. (b) What is the reflected input primary side impedance of the transformer? ele ll
Q: A Transformer with 10:1 ratio and rated at 50-kVA, 2400/240-V, 50-Hz is used to step down the…
A:
Q: A single-phase, dry-type, general-purpose industrial distribution A transformer has the…
A: Given data, P=50 kVAf=60 HzVH=480 VVL=120 VZimpedance=3.80+j4.43 Ω%R=3.80 Ω%X=4.43 ΩPi=105 W
Q: The primary and secondary windings of a 500 kVA transformer have resistances of 0.44 Ω and 0.0027 Ω,…
A: The solution is given below
Q: 2) The following no-load results are obtained at the excitation branch of a 10, 20 kVA, 2400/240 V,…
A:
Q: A 2,300/240-V, 60-Hz, 4.6-kVA transformer isdesigned to have an induced emf of 2.5 V/turn.Assuming…
A: The given transformer is a step-up transformer. a. The numbers of high-side turns are calculated as…
Q: Example 1: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results:…
A:
Q: Given a transformer (single-phase, 10kVA, 2400/240V, 60Hz) Z1 = 5.2 + j12.5 ohms; Z2 = 0.06 + j0.12…
A: In this question we need to find a load voltage of transformer for given condition.
Q: ABB company manufactures 44 kVA, 2200/220 V conventional transformer. Using this transformer, design…
A: In autotransformer, the same winding works both primary and secondary. AB- is known as series…
Q: Q2: A 4000/400 V, 10 kVA transformer has the following constants: Primary and secondary winding…
A: Given values are -
Q: (d) A step-down transformer is rated 10KVA, 7500/250 V and has the following equivalent circuit…
A: In this question, We need to determine the equivalent winding impedance referred to the high…
Q: The equivalent circuit of a 22KVA, 11700/520 V, 60HZ, single-phase loaded transformer when referred…
A: In this question we need to find a efficiency of Transformer .
Q: The parameters of a 1200/300V. 50HZ single phase transformer are given below: R-5N, X-10 fn, R 0.3…
A: The equivalent circuit of a transformer represents the behavior of the transformer with the help of…
Q: A 40-kVA, 8000/230-V distribution transformer has an impedance referred to the primary of 18 + j80…
A: In this question we need to find a secondary voltage of the transformer.
Q: Q2: A 4000/400 V, 10 kVA transformer has the following constants: Primary and secondary winding…
A: The transformation ratio of the transformer is determined as:
Q: The rating of current transformer is given as 200/5A 5P10 20VA. Assume that the secondary resistance…
A: Given CT secondary resistance =Rc t =0.12 Ω from CT data 200/5A 5P10 20VA Sn =20 VA I=5 A Fn=10
Q: 2.2: The parameters of a 200/3000V, 50HZ single phase transformer are given below: R=0.018 N,…
A: (i) The equivalent circuit for the given problem is,
Q: step-down transformer has a ratio of transformation of 10:1 and is connected to a 2,300- V, 60 hz ac…
A: In this question we will find secondary voltage, primary current , power input and output... Note:-…
Q: (a) A 5 MVA 230/10.5-kV single-phase power transformer has a per-unit resistance of 1.5% and a…
A:
Q: A 400-k VA, 2300 230, 60-hz transformer supplies a 0.8 lagging power-factor load whose KVA Is…
A: The efficiency of the transformer is given by the relation, Where, x = percent rated load…
Q: A 230-kVA, 2300/230-V, 60-Hz, step-down, two-winding transformer has the following parameters RH =…
A: Given data: S=230 kVARH=1.2 ΩRL=12 mΩXH=3 ΩXL=30 mΩRcH=2 kΩXmH=1.8 kΩVp=2300 V
Q: Power transformer A, has Rated power of 150MVA. Line voltage of 330/66 kV Frequency=50Hz Connection…
A: Active Power across the Load = Apparent Power ×power factor ---- 1) Putting value in equation -1)…
Q: 1. A 40-MVA, 20/400 kV, single-phase transformer has the following series impedances: ZLV = 0.9 +…
A: Introduction: An equivalent Transformer Circuit is an explanation of the transformer's behavior by…
Q: The parameters of a 1000/250V, 50HZ single phase transformer are: R1=1.3 N, X1=2.8 N, R2=0.11 N,…
A:
Q: The parameters of a 200/400V 50HZ single phase transformer are given below: Zı= 0.2 + j0.4 N, Zz=…
A:
Q: A transformer takes a No load current of 0.22 A and power factor of 0.547 lag, when its primary is…
A: Given, No load current (Io)= 0.22 A No load power factor= 0.547 lagging No load supply voltage…
Q: A 2000/400 V, 100 kVA, 60 Hz step-down single-phase transformer has a primary and secondary…
A:
Q: For a 150 kVA, 2400/240 V transformer, the equivalent circuit parameters are given as R1 = 0.2 Ohm,…
A:
Q: A 2.4-kVA, 2400/240-V, 50-Hz, step-down transformer has the following parameters: R, = 1.5 a, X, =…
A:
Q: A 1000-VA, 230/115-V traformer has been tested to determine its equivalent circuit. The results ar…
A: A transformer is an electrical machine which is used in AC circuit to either step up or step down…
Q: The parameters of a 200/400V 50Hz single phase transformer are given below: Z₁=0.5+j1.8, Z₂= 0.2 +…
A:
Q: A 230/400 V single-phase transformer absorbs 35 W when its primary winding is connected to a 230 V,…
A:
Q: ABB company manufactures 44 kVA, 2200/220 V conventional transformer. Using this transformer, design…
A:
Q: A 50-kVA, 2600/1300-V, single-phase transformer has a core loss of 780 W. The transformer has a high…
A:
Q: Nominal tests 50 kVA, 20,000 / 480 V, 60 Equivalent of single phase transformer in Hz to determine…
A:
Q: Q4. A 100KVA, 200/4000V Y-A transformer has per phase in per-unit system Regpa"0.3, Xegga"0.4,…
A: Given: A 100 kVA, 200/4000 V Y-Δ transformer has per phase in the per-unit system Req.pu=0.3…
Q: Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer…
A: In this question we need to find a input power factor of transformer.
Q: The parametens of the aquivalent circuit of a 4-kVA, 200/400-V transformer referred to the…
A: The low voltage side is the primary side. Secondary side voltage Vs=200 Volt. Load impedance…
Q: Q1 The oil test condition analysis is the ultimate starting point for any HV transformer assessment.…
A:
Q: Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer…
A: In this question we need to find a voltage regulation of transformer
Q: A, determine V½ l, Z, and the impedance Z',, which is the value of Z, referred to the primary side…
A: Given: N1=1000N2=250V1=1000∠0°I1=5∠30° The relation between voltage and the turns of the transformer…
Q: 1. An ideal transformer with N = 2400 and N2 400 is connected with an impedance Z2 across winding 2,…
A:
Q: 2. A single-phase 100KVA, 1400/200 volt, 50 Hz, distribution transformer is used as a step- down…
A: Transformer is a static device which is used to step up / down the voltage or current level in the…
Q: Parameters of a distribution transformer of 20 kVA, 2200/220 V, 50 Hz, R1 -5Ω R2-0.04 Ω Rc-3000 Ω…
A: Dear student as per our guidelines we are supposed to solve only one question in which it should…
Q: A 20-KVA, 20,000/480-V, 60-Hz distribution transformer is tested with the following results:…
A: Given Parameters of a distribution transformer. We need to sketch the per equivalent circuit.…
Q: The parameters of a 400/100V, 50Hz single phase transformer are given below: Z 1+j10, Z₂= 0.1 +…
A:
Q: Primary side-reduced equivalent circuit parameters of a 25 KVA, 50 Hz, 4000/400 Volt transformer R1…
A: Given: A 25KVA, 50Hz, 4000/400V transformer in which…
Q: Parameters of a distribution transformer of 20 kVA, 2200/220 V, 50 Hz, R1 = 5 0 R2=0.04 Q Rc=3000 0…
A: Distribution transformer 20KVA , 2200/220 V, 50Hz R1 = 5 ohm, R2 = 0.04 ohm, X1 = 15 ohm, X2 =0.14…
Q: The parameters of a 1200/300V. 50HZ single phase transformer are given below: R,-50, X,-10 0, R 0.3…
A: We are authorized to answer three subparts at a time, since you have not mentioned which part you…
Step by step
Solved in 2 steps
- Consider an ideal transformer with N1=3000andN2=1000 turns. Let winding 1 be connected to a source whose voltage is e1(t)=100(1| t |)volts for 1t1ande1(t)=0 for | t |1 second. A2- farad capacitor is connected across winding 2. Sketch e1(t),e2(t),i1(t),andi2(t) versus time t.all äabl (CME 446) 1 If F3=0.1 and Z3=45 Q, then the impedance of the next stage in the multi-section transformer is: of O a. 40.5 stion O b. 49.5 O C. 55 O d. None O e. 36.8 s page Next pageIn the circuit in Figure 2, the capacitor connected to the a-b terminals of the transformer anda circuit consisting of resistance is defined as a load circuit. a)Find the average power spent by the load circuit? b) How much of the average power calculated in a) by the resistance in the load circuit and how muchspent by the capacitor? Comment on the results obtained?
- 1. A 2.4-KVA, 2400/240-V, 50-Hz, the step-down transformer has the following parameters: : RH = 1.59, :XH = 2.50, R₂ = 0.020, X₁ = 0.030, : Rc = 6k2, and: Xm = 8kQ. It is operating at 50% of its load at 0.5 power factor leading. Using the exact equivalent circuit embodying the ideal transformer, determine the efficiency of the transformer. Also, sketch its phasor diagram.Q5. For the following center tapped transformer, show the waveform across each half of the secondary winding and across R, when a 100 V peak sine wave is applied to the primarywinding. What is the PIV rating must the diodeshave? (Use constant voltage drop model for the Silicon diode) D IN4001 OV 10 kN IN4001 DELLThe windings of an 11500/2300V two winding transformer are connected in series, with 11500 V as the supply to the primary, to create an autotransformer. What is the voltage output of the resulting step-up autotransformer when Ip and Is are 10 A and 50 A, respectively?
- 10 A three-phase transformer is given. The number of turns of the high voltage winding is N1=850 and the number of turns of the low voltage winding is N2=34. The high voltage winding is energized with V1= 10 kV rms line-to-line and V2= 400 V rms line-to-line has been taken from the low voltage winding. What is the connection of the low voltage winding if the high voltage winding is Y-connected? Εισαγάγετε την απάντησή σαςFlag this question for future reference What is the test that can be conducted in the laboratory to understand the transformer impedance drops are dependent on the load current with a variation in the secondary voltage? O a. Direct Load Test O b. Open Circuit Test OC. Voltage Ratio Test O d. Polarity TestIn the circuit shown in the figure, a voltage with a peak value of 212.16 V is applied to the input of the secondary transformer with common winding. The ratio between transformer windings is 5: 2. Find the Vrms value on VS2. A 59,98 Vrms B 29,99 Vrms C 42,43 Vrms D 84,86 Vrms E 42,52,99 Vrms
- Single phase half wave AC-AC converter has a resistance of R = 50 ohms. Input voltage is given as 230 Vrms. Transformer conversion ratio is 1:1. If T1 thyristor is triggered at 60 degrees; a)Rms output voltage? b)Output power? c)RMS load current and average load current? d)Input power factor? e)Average and RMS thyristor current?A three-phase transformer is given. The number of turns of the high voltage winding is N1=850 and the number of turns of the low voltage winding is N2=34. The high voltage winding is energized with V1= 10 kV rms line-to-line and V2= 400 V rms line-to-line has been taken from the low voltage winding. What is the connection of the low voltage winding if the high voltage winding is Y-connected? *Draw the scheme of a single-phase transformer with two secondary windings and mark the main symbols and quantities. Write the formulas to determine the total power P1, the transformation ratios and the primary current I1.