A lossless 60 ohm line is terminated by a 60+j60 ohm load .If Zin =120- j60ohm. How far (in term of wavelength) is the load from generator.
Q: A lossless transmission line having 50 Q characteristic impedance and length N4 is open circuited at…
A: Given Lossless transmission line Characteristic impedance Z0=50 ΩLength l=λ4open circuitedVoltage…
Q: Since the output power of a non-reflective and lossless transmission line terminated with a load…
A: We need to calculate input power for given output power for a given lossless and non reflective line…
Q: Consider the three 50 2 lossless line shown in figure below Line 3 Z, 100n Line 1 Z. 2, Line 2 S.C.…
A: Given: In the given circuit first of all they have mentioned three 50 ohm lossless lines. The…
Q: Why is the Geometric Mean Distance (GMD) of two different conductors the same in a transmission line…
A: GMR stands for geometric mean radius which is also known as self GMD it is mean of the distance of…
Q: A 50-N lossless line is terminated in Z, = 40 – j30 N. Determine the following: (a) the reflection…
A: A 50Ω lossless line is terminated in Z1=40-j30Ω. Now, to determine the reflection coefficient at the…
Q: A lossless transmission with characteristic impedance of ?0 = 100Ω and length = 52cm The line was…
A: Given:Characteristic impedance,Z0=100ΩLoad impedance, ZL=30 +j50Ω
Q: A lossless 50 ohms transmission line is connected to unknown load impedance. Voltage measurements…
A: For the above-given data load reflection. load impedance and the distance is calculated as shown…
Q: A load with an impedance of 424.3045° N is connected to a 100 N lossless line. Using the Smith Chart…
A:
Q: Explain what will happen to the characteristic impedance when the spacing between the center of two…
A: We know direct formula of two conductor transmission line.
Q: The observed standing wave ratio on a 100 Ω lossless line is 8. If the first voltage maximum occurs…
A: Given: Z0=100 Ω Standing wave ratio, S = 8 First maximum (n = 1) occur at dmax=0.3λ
Q: If a lossless line is terminated in an inductive load, (a) will the input impedance be purely…
A:
Q: A 40Ω lossless line is connected to an 18V source with Zg = 50Ω and terminated on a ZL = 20Ω load.…
A: Given Lossless line Z0=40 ΩZg=50 ΩZL=20 Ωβ=0.2 rad/mlength from the load L=5 m
Q: A coaxial cable is 10 meters long, and is filled with lossless Teflon, having a relative…
A:
Q: What is the necessary condition for matching transmission lines? In addition, what is a micro strip…
A: necessary condition for matching transmission line micro strip line
Q: A lossless transmission line l = 0.3lambda in length was terminated with a complex load of ZL =…
A: Given Data: l = 0.3lambda ZL = 30-j20 ohms characteristic impedance for the line is Zo = 75 ohms
Q: Two identical pulses each of magnitude 12 V and width 2 us are incident at i = 0 on a lossless…
A: Wave is function of space and time. The mode at which waveguide have lowest frequency is said to be…
Q: What is the justification in neglecting line capacitance in short length transmission lines?
A:
Q: Compute the following parameters inductance, Capacitance, resistance, and conductance, if you have…
A:
Q: Why is the Geometric Mean Distance (GMD) of two different conductors the same in a transmission line…
A: We have given the following problem
Q: The capacitance per unit length and the characteristic impedance of a lossless Transmission line are…
A: It is given that, the capacitance per unit length and the characteristic impedance of a lossless…
Q: A lossless transmission line with Zo=78 [Ohms] is terminated with load ZL=39+j62.4 [Ohms]. If the…
A: “Since you have posted a question with multiple sub-parts, we will solve the first three sub-parts…
Q: A loss-less 200N line is terminated on a load given by (200-j200)№. Given that the propagation…
A: the Given loss-less 200Ω line is terminated on a load 200-j200Ω The Propagation constant is…
Q: A 376-2 lossless air transmission line is connected to a complex load composed of a 749-2 resistor…
A:
Q: A lossless 60-2 line is terminated by a 60 + j60-N load. If Z, = 120 - j60 , how far (in terms of…
A: Reflection coefficients determine how much wave is reflected at discontinuity of medium.It is given…
Q: A lossless 500 transmission line was terminated with a load of = 17.7 + j11.80. The length of the…
A: we need to calculate the reflection coefficient at the entrance.
Q: A lossless air-filled transmission line with Z0 = 50Ω is terminated in a load with ZL = (150 - j100)…
A: Lossless air-filled transmission line with Zo=50Ω is terminated withZL=150-j100Ω.Reflection…
Q: Derive an expression for sag in a transmission line of equal hight poles.
A: We have to derive formula of sag for equal height poles in a transmission line.
Q: Example 5 (HW): For the lossless TL shown in below with length l and characteristic impedance Z9,…
A: A uniform transmission line's characteristic impedance or surge impedance (commonly written Z0) is…
Q: Example 1: For the lossless TL shown in below with length l, let Zg = 0 and ZR = 3Z9. Use Zig-zag…
A: 1)
Q: A lossless transmission line having 50 Ω characteristic impedance and length λ/4 is short-circuited…
A:
Q: Assuming a lossless line, what is the surge impedance of a power system with a three-phase 420 kVLL…
A: In this question we will find surge impedance of line...
Q: A lossless 50 transmission line was terminated with a load of = 17.7 + jl1.8N. The length of the…
A: The solution can be achieved as follows.
Q: A 50 ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at…
A: Input Impedance- It is define as the opposition to the current offered by the circuit at input end.
Q: -ohm resistive load and is operated at 100 MHz. At an electrical length of 0.4 wavelengths, what is…
A:
Q: What parameters determine the characteristic impedance of Lossless transmission
A: In this question we will write parameters which determine the characteristic impedance of Lossless…
Q: Vk(t)= 9cos2π * 10^6(t) volt Voltage of a lossless transmission line fed by its source parameters,…
A: For a transmission line, VsIs=coshγlzcsinhγl1zcsinhγlcoshγlVrIr Propagation constantγ=zy=α+jβ…
Q: A lossless transmission with characteristic impedance of Z0 = 1002 and length = 52cm The line was…
A:
Q: A lossless TL with characteristic impedance of to is terminated in Zv=3Z0. use crank diagram to…
A: Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: A 75 Ω lossless line is terminated in error with a 93 Ω resistor. A generator sends 100 mW down the…
A:
Q: A 50-ohm lossless transmission line is terminated by a 100-ohm resistive load and is operated at 100…
A:
Q: A 75 Q lossless transmission line is to be matched with a 100-j802 load using Single stub. Calculate…
A: Given :Z0=75 ΩZL=100-j80 ΩZL=128.06∠38.66° f=30 MHz
Q: A lossless 60-2 line is terminated by a 60 + j60-2 load. If Zin = 120 - j60 N, how far (in terms of…
A: The wave is function of space and time. The EM wave is formed when electric field is in contact with…
Q: A lossless transmission line having 50 N characteristic impedance and length 1/4 is short circuited…
A: Evaluating the input impedance:
Q: A material with &r = 2.25 is used as the insulating material in a lossless coaxial line with…
A: “Since you have asked multiple questions, we will solve the first question for you. If you want any…
Q: The distance from the load to the source moving on a lossless transmission line is 2.5 revolutions…
A: The transmission lines are used for power transmission from one place to another. The power system…
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- The affect of the earth plane is to slightly increase the capacitance, and as the line height increases, the effect of earth becomes negligible. True FalseParagraph Styles The power factor must be close to in the transmission lines will be reduced To insure that losses D(Ctrl) -19- Noise due to inductive coupling can be reduced by twisting the wires carrying a signal. True False
- A loss less TiL with characteristic impedance of to is terminated in Zr=3Z0. use crank diagram to sketch the voltage versus distance from the load, (Assume vst = 1 volt). @ Repeat the above How for Zv=Zo/3-The total reactive power consumed by the three-phase load(in VAr) is??A Three phase transposed line is composed of one conductor per phase with flat horizontal spacing of D as shown in the below figure. If GMD is 15.119 meters, then D will be a b D 2D Select one: Oa 12 meters Ob. None of these Oc15367 meters Od 14 meters
- Find the inductive reactance per mile of a single-phase line operating at 50 Hz. The conductor has a GMR of D, 0.0217 ft, and spacing GMD is 15 ft between centers. O 0.41 O 0.66 O 0.79 O 0.494/ Which parameter is neglected or ignored in Short Transmission Lines? A. SHUNT CAPACITANCE ONLY B. SERIES CONDUCTANCE AND SHUNT CAPACITANCE C. SHUNT CONDUCTANCE AND SHUNT CAPACITANCE D. SHUNT CONDUCTANCE ONLYA single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight 1-The capacitance in uF/km without effect of ground is 2-The capacitance in pF/km with effect of ground is
- One circuit of a single-phase transmission line is composed of three solid 0.12" radius wires. The return circuit is composed of two 0.15" radius wires. Find the inductance of the complete line in mH/mi. The distance between wires are 40" horizontally and 25" vertically. A. 2.54 mH/mi B. 2.478 mH/mi C. 2.488 mH/mi D. 2.567 mH/mi Provide Clear ExplainationDefine electronegative gases and Compare between SF6 and 02 Insulator? Explain the different schemes for cascade connection of transformers for producing very high ac voltages?2.5 A 3-phase single circuit bundled conductor line with two sub-conductors per phase has horizontal spacing with 6.1 m between the centre lines of adjacent phases. The distance between the sub- conductors of each phase is 30.5 cm and each sub-conductor has a diameter of 2.54 cm. Find the inductance per phase per km. [0.988 mH]