Question
Chapter 2, Problem 13P
To determine
Find the external wind pressure acting on the windward and leeward side of the roof of the building.
Expert Solution & Answer
Trending nowThis is a popular solution!
Students have asked these similar questions
Determine the external wind pressure on the roof of the rigid-gabled frame of a building for an essential disaster operation center shown in Fig. P2.14. The building is located in Kansas City, Missouri, where the terrain is representative of exposure C and the basic wind speed for risk category IV buildings is 120 mph. Assume the wind direction is normal to the ridge, as shown in the figure. Use Kd 50.85 for main wind-force resisting systems, and Ke =1
Determine the external wind pressure on the roof of the rigid-gabled frame of a school building shown in Fig. P2.13. The structure is located in a suburb of Chicago, Illinois, where the terrain is representative of exposure B and the basic wind speed for risk category III buildings is 51 mys. Assume the wind direction is normal to the ridge as shown. Use Kd 50.85 for main wind-force resisting systems, and Ke =1.
Determine the external wind pressure on the roof of the rigid-gabled frame of an apartment building shown in Fig. P2.12. The building is located in the Los Angeles area of California, where the terrain is representative of exposure B. The wind direction is normal to the ridge as shown. Use Kd 50.85 for main wind-force resisting systems, and Ke 51.
Knowledge Booster
Similar questions
- . Determine the external wind pressure on the roof and wall of the rigid-gabled frame of an enclosed building for an essential disaster operation center shown in Figure. The building is located in Kansas City, Missouri, on open flat terrain. The wind direction is normal to the ridge, as shown in the figure. Assume V=95 mi/hr ( Wind Plan 10° 12m- Elevation 10m h 10marrow_forwardDetermine the external wind pressure on the roof of the rigid gabled frame of a nonessential industrial building shown in Fig. 2.13(a). The structure is located in a suburb of Boston, Massachusetts, where the terrain is representative of exposure B. The wind direction is normal to the ridge of the frame as shown.arrow_forwardQuestion 3 The wind blows uniformly on the front surface of the metal building with a pressure of 1.8 kN/m?. Determine the resultant force it exerts on the surface and the position of this resultant. y 2.5 m 1.0 m 2.5 m. 2.5 m.arrow_forward
- The roof of a single-story storage building, shown in Fig. P2.1, is subjected to a uniformly distributed load of 0.96 kPa over its surface area. Determine the loads acting on the floor beam BE and the girder AC of the framing system.arrow_forwardDetermine the design snow loads for the roof of the gabled frame of an apartment building shown in Fig. 2.13(a). The building is located in Chicago, Illinois, where the ground snow load is 25 psf. Because of several trees near the structure,assume the exposure factor is Ce =1.arrow_forwardA 20 storey RC framed building has plan dimensions 15 m × 30 m. Height of the building is 100 m. The fundamental period of vibration, if the building is unbraced, will bearrow_forward
- Problem No. 4 A two-story apartment has interior columns that are spaced 4.5 meters apart in two perpendicular directions. If the loading on the flat roof is estimated to be 1.00 kN/m?, determine the live load supported by a typical interior column at (a) the ground-floor level, and (b) the second floor level. Hint: Use Reducible Live Load Formulaarrow_forwardGiven. A two-story OCBF shown in Fig. 3.40c that forms part of the building frame system in SDC E. The axial loads on the ground floor brace B1 are as follows: Dead load D= 30 kips Live load L= 15 kips Seismic force QE = ±80 kips Snow load S= 0 kips Hydrostatic load H = 0 The redundancy coefficient p = 1.1. Mapped two-second såpectral acceleration, Sps = 0.826 g. Required. Determine a pipe section for brace B1, ASTM A53 Grade B steel; F, = 35 ksi, F = 60 ksi 16 ft 16 ft Figure -15 ft B2 B1 -- -15 ft B2 B1 Ordinary concentric brace frame (OCBF) example.arrow_forwardA wall form 8 ft high is filled with 150 lb per cu ft concrete at a tempera- ture of 60°F. The concrete is Type I with a retarder. Concrete will be placed with normal internal vibration to a depth of less than 4 ft. The concrete rate of placement will be 10 ft per hr. 12 ft 5.3 ft P=793 lb per sq ft Top of wallarrow_forward
- 1. The enclosed building shown in the figure below is used for storage purposes and is located at Calapan on an open terrain, 5km away from the nearest fault line that can produce an 8.0 magnitude earthquake. When the wind is directed as shown and the weight of the structure is 1000KN. Determine the base shear that will govern the design. Use (-) GCpi and soil profile type SD for the design. 7,5 m 10 22.5 m 45 m. 22.5 m windarrow_forwardAn eight Storey city library is proposed to be constructed in Baguio. The structure shall be a reinforced concrete building (no shear walls). The weight per floor (including 1st floor) is estimated to be 1800 KN. The roof deck weighs 1700 KN. Solve for the Base Shear, V, for the condition above using the following formulas: 1. V =ZICKSW (SEAOC CODE 1974 - 4 TH Revision) Adopted by National Structural Code of the Philippines, 3rd edition (NSCP 1987) 2. V = ZICW/Rw National Structural Code of the Philippines, 4th edition (NSCP 1992), Volume I 3. Most critical formula for V as indicated in Sec. 208.5.2 of the NSCP Vol.1 5th edition (2001). 4. Most critical formula for V as indicated in the NSCP Vol.1 6th edition (2015). 1700 KN 100 KN 32 1800 KN La Tide Toeang Warg 32 1800 KN 32 259 32 1800 KN 32 1800 KN City Cam Cena, Nagun C Bengt Nearet Active failt Trace t Fae tunao Fa Segnet Nane Tut Fat Vear Maper 2012 Ma t et 10 00 32 1800 KN 3.5 20 Floor height: 1st floor 3.5m and the rest of the…arrow_forwardUse the ASCE 7 equations for building vibration period and base shear and calculate the design base shear for the following building. Building information: Building height:Location:Function:Total building weight:Structural system: 160-ft tallSanta Monica, CA (Seismic Design Category E)Hospital (Importance factor, I =1.5)7,400 kipsSteel eccentrically braced frame (R= 8)arrow_forward