Write True or False and correct the wrong statement (Ans
7. The unit nearest to the cross-arm in tower has maximum voltage
across it and hence it likely to be repaired.
8. Corona losses in DC Transmission supply 10 times more than
AC transmission.
9. Irregularity Factor (mv) has value of 0.9 to 0.95 in rough
conductor.
10.Power losses in corona dissipated in the form of conductor
vibrating.
11. The corona loss on a particular system at 50 Hz is 1 kW/Km per
phase but for the same system but 60 Hz will be 1.5 kW/Km per
phase.
12.If the number of poles in 3ph 11kV transmission line is 80, then
we need 420 discs to suspend the conductor on these poles.
A circuit breaker is rated as 132 KV, 4000
MVA. What will be the Asymmetrical
breaking current capacity if DC component
is assumed to be 70% ?
Explain the concept of symmetrical and unsymmetrical faults in power systems. How are these faults analyzed, and what protective measures can be implemented?
Knowledge Booster
Similar questions
- complet The equivalent reactance of the double circuit line under post fault condition is................than fault condition.arrow_forwardIn a CE configuration, the voltage gain is __________ . a.always positive b.negative c.almost zero d.very lowarrow_forwardDescribe how a fault in long cable can be detected and located using partial discharge technique High voltage engineeringarrow_forward
- 2. What's the primary instrument for locating a break in a cable during emergency maintenance?A. OSAB. OTDRC. MultimeterD. Power meterarrow_forwardDescribe the concept of fault current analysis in power systems and its role in protecting electrical equipment.arrow_forwardWrite in detail about cable fault location using Varley loop test.With appropiate diagram.arrow_forward
- estion 9 The fault current level of a circuit breaker used in a transmission line with phase voltage 2.2 kV and breaking capacity 50 MVA is yet ......kA. vered -ked out of Flag question estion 10 The voltage between lines in a transmission line is the maximum value of the sine waveform. yet vered Select one: -ked out of O True Flag question O Falsearrow_forwardWhat are the values of the load and line regulation for the circuit shown?arrow_forwardThe parameters of the _________equivalent circuit are defined in general terms for any operating conditions. a.hybrid-pi b.hybrid c.re d.piarrow_forward
- iv. The swing equation can be considered mathematically, as a equation due to the v. The main objects of fault analysis are term.arrow_forwardDefine percentage line and load regulationarrow_forwardWhat is meant by FACTS in power systems? Discuss about SVC type FACTS device. What type of fault is three phase short circuit fault in power system.(Symmetrical or Unsymmetrical). Discuss about the chance of occurrence of the above mentioned type of fault.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning