You may use the empirical formula for ideal fill factor: ffo = voc-In (voc+0.72) VOC+1 qV oc where Voc KBT A module is delivered with a label as shown in the picture. When operating at environment temperature of 35 °C and irradiance of 1000W m-², what is its surface temperature? what is the series resistance of the module at standard condition? ● = Solar Jinko Building Your Trust in Solar PHOTOVOLTAIC Open Circuit Voltage Short Circuit Current MODULE Solar Module Type: JKM295M-60 Maximum Power Power Tolerance Maximum Power Voltage Maximum Power Current www.jinkosolar.com Operating Temperature Application Class Module Fire Performance Weight Dimension (Pmax) (Vmp) (Imp) (Voc) (Isc) (NOCT) Nominal Operating Cell Temp Maximum System Voltage Maximum Series overcurrent protective device rating 295W 0~+3% 32.4V 9.10A 39.7V 9.61A 45±2°C 1500VDC 15A -40°C~+85°C A Type 1 19.0(kg) 1650x992x40(mm) STC: 1000W/m', AM1.5, 25°C System Fire Class Rating: See Installation Instructions for Installation Requirements to Achieve a Specified System Fire Class Rating with this Product The fire rating is Class C in Canada
You may use the empirical formula for ideal fill factor: ffo = voc-In (voc+0.72) VOC+1 qV oc where Voc KBT A module is delivered with a label as shown in the picture. When operating at environment temperature of 35 °C and irradiance of 1000W m-², what is its surface temperature? what is the series resistance of the module at standard condition? ● = Solar Jinko Building Your Trust in Solar PHOTOVOLTAIC Open Circuit Voltage Short Circuit Current MODULE Solar Module Type: JKM295M-60 Maximum Power Power Tolerance Maximum Power Voltage Maximum Power Current www.jinkosolar.com Operating Temperature Application Class Module Fire Performance Weight Dimension (Pmax) (Vmp) (Imp) (Voc) (Isc) (NOCT) Nominal Operating Cell Temp Maximum System Voltage Maximum Series overcurrent protective device rating 295W 0~+3% 32.4V 9.10A 39.7V 9.61A 45±2°C 1500VDC 15A -40°C~+85°C A Type 1 19.0(kg) 1650x992x40(mm) STC: 1000W/m', AM1.5, 25°C System Fire Class Rating: See Installation Instructions for Installation Requirements to Achieve a Specified System Fire Class Rating with this Product The fire rating is Class C in Canada
Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.8MCQ: An ac resistance is higher than a dc resistance. True False
Related questions
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 4 steps with 13 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning