You may use the empirical formula for ideal fill factor: ffo = voc-In (voc+0.72) VOC+1 qV oc where Voc KBT A module is delivered with a label as shown in the picture. When operating at environment temperature of 35 °C and irradiance of 1000W m-², what is its surface temperature? what is the series resistance of the module at standard condition? ● = Solar Jinko Building Your Trust in Solar PHOTOVOLTAIC Open Circuit Voltage Short Circuit Current MODULE Solar Module Type: JKM295M-60 Maximum Power Power Tolerance Maximum Power Voltage Maximum Power Current www.jinkosolar.com Operating Temperature Application Class Module Fire Performance Weight Dimension (Pmax) (Vmp) (Imp) (Voc) (Isc) (NOCT) Nominal Operating Cell Temp Maximum System Voltage Maximum Series overcurrent protective device rating 295W 0~+3% 32.4V 9.10A 39.7V 9.61A 45±2°C 1500VDC 15A -40°C~+85°C A Type 1 19.0(kg) 1650x992x40(mm) STC: 1000W/m', AM1.5, 25°C System Fire Class Rating: See Installation Instructions for Installation Requirements to Achieve a Specified System Fire Class Rating with this Product The fire rating is Class C in Canada

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter4: Transmission Line Parameters
Section: Chapter Questions
Problem 4.8MCQ: An ac resistance is higher than a dc resistance. True False
icon
Related questions
Question
You may use the empirical formula for ideal fill factor: ffo voc-In (voc+0.72)
Voc+1
qV oc
КВТ
A module is delivered with a label as shown in the picture. When operating at
environment temperature of 35 °C and irradiance of 1000W m²,
what is its surface temperature?
what is the series resistance of the module at standard condition?
where Voc =
Solar
Jinko
Building Your Trust in Solar
PHOTOVOLTAIC
MODULE
Solar Module Type: JKM295M-60
Maximum Power
Power Tolerance
Maximum Power Voltage
Maximum Power Current
Open Circuit Voltage
Short Circuit Current
www.jinkosolar.com
(Pmax)
(Vmp)
(Imp)
(Voc)
(Isc)
(NOCT)
Nominal Operating Cell Temp
Maximum System Voltage
Maximum Series overcurrent protective device rating
Operating Temperature
Application Class
Module Fire Performance
Weight
Dimension
295W
0~+3%
32.4V
9.10A
39.7V
9.61A
45±2°C
1500VDC
15A
-40°C~+85°C
A
Type 1
19.0(kg)
1650x992x40(mm)
STC: 1000W/m, AM1.5, 25°C
System Fire Class Rating: See Installation Instructions for Installation
Requirements to Achieve a Specified System Fire Class Rating with this Product
The fire rating is Class C in Canada
Transcribed Image Text:You may use the empirical formula for ideal fill factor: ffo voc-In (voc+0.72) Voc+1 qV oc КВТ A module is delivered with a label as shown in the picture. When operating at environment temperature of 35 °C and irradiance of 1000W m², what is its surface temperature? what is the series resistance of the module at standard condition? where Voc = Solar Jinko Building Your Trust in Solar PHOTOVOLTAIC MODULE Solar Module Type: JKM295M-60 Maximum Power Power Tolerance Maximum Power Voltage Maximum Power Current Open Circuit Voltage Short Circuit Current www.jinkosolar.com (Pmax) (Vmp) (Imp) (Voc) (Isc) (NOCT) Nominal Operating Cell Temp Maximum System Voltage Maximum Series overcurrent protective device rating Operating Temperature Application Class Module Fire Performance Weight Dimension 295W 0~+3% 32.4V 9.10A 39.7V 9.61A 45±2°C 1500VDC 15A -40°C~+85°C A Type 1 19.0(kg) 1650x992x40(mm) STC: 1000W/m, AM1.5, 25°C System Fire Class Rating: See Installation Instructions for Installation Requirements to Achieve a Specified System Fire Class Rating with this Product The fire rating is Class C in Canada
Expert Solution
steps

Step by step

Solved in 4 steps with 13 images

Blurred answer
Knowledge Booster
Dielectric breakdown
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning