Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN: 9780133923605
Author: Robert L. Boylestad
Publisher: PEARSON
Bartleby Related Questions Icon

Related questions

bartleby

Concept explainers

Question
You have been hired as an engineering consultant to diagnose an overheating and low output voltage
problem with a three-phase transformer. The service technicians informed you that the transformer has a
solid nickel core, insulated aluminum windings and a single phase of the transformer is rated at 50 kVA,
6900/400 V, 60 Hz. The transformer cannot be disconnected for open and short circuit testing and only the
input lines and output outlets are accessible for current and voltage measurements.
(a) The following measurements were taken after and during working hours when all the electrical devices
were off and on,respectively.
No load condition:
Input Phase Current = 32-60°A,
Output Voltage = 400<0°V
Load condition:
Input Phase Current = 8.452-37.35°A,
Output Voltage = 370Z-0.64°V
Assuming the input voltage is maintained at its rated value, calculate the modelled internal parameters Ro,
Xm, Reqand Xeq of the transformer referred to the high voltage side.
expand button
Transcribed Image Text:You have been hired as an engineering consultant to diagnose an overheating and low output voltage problem with a three-phase transformer. The service technicians informed you that the transformer has a solid nickel core, insulated aluminum windings and a single phase of the transformer is rated at 50 kVA, 6900/400 V, 60 Hz. The transformer cannot be disconnected for open and short circuit testing and only the input lines and output outlets are accessible for current and voltage measurements. (a) The following measurements were taken after and during working hours when all the electrical devices were off and on,respectively. No load condition: Input Phase Current = 32-60°A, Output Voltage = 400<0°V Load condition: Input Phase Current = 8.452-37.35°A, Output Voltage = 370Z-0.64°V Assuming the input voltage is maintained at its rated value, calculate the modelled internal parameters Ro, Xm, Reqand Xeq of the transformer referred to the high voltage side.
Expert Solution
Check Mark
Knowledge Booster
Background pattern image
Electrical Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Text book image
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Text book image
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Text book image
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Text book image
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Text book image
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Text book image
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,