Question
What type of fault is three phase to earth fault in power system.(Symmetrical or Unsymmetrical).
Discuss about the chance of occurrence of the above mentioned type of fault.
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 3 steps with 1 images

Knowledge Booster
Similar questions
- 1. The subscript d in the generator subtransient reactance refers to: 1. Generator impedance 2. If the available fault current slightly exceeds the breaker published 2. Generator 3. Direct axis 4. 1 and 2 reactance interrupting rating, then it is safe to use the breaker. 1. True | 2. False 3. Maybe 3. The rms symmetrical fault current times an asymmetry factor K, is equal to the ac fault current. | 2. False 4. The most common fault on a 3-phase power system is: 1. True 3. Maybe | 2. DLG 3. L-L 1. SLG 5. All rotating and non-rotating load impedances are usually included in a power system fault study 1. True 2. False 3. Мaybearrow_forwardPlease solve Q1(B) ONLY. Q1(A) is for reference.arrow_forwardExplain the concept of a circuit breaker in electrical power systems and its role in protecting against overcurrent faults.arrow_forward
- Q.3 When a line-to-ground fault occurs, the current in faulted phase 'a' is 100A. The zero-sequence current in phase 'c' is rarrow_forwardWhich of the following correctly orders how frequently each type of fault occurs?- a. balanced three-phase. single line to ground, Line to line , double line to ground, b. single line to ground, Line to line , double line to ground, balanced three-phase c. All the samearrow_forwardFigure 2 shows the circuit of a simple power system. The ratings of the generators, transformers and the motors are as shown in the figure. The reactance of lines 1 and 2 are 40 ohms and 50 ohms respectively. Assume that system is unloaded, and the generators are generating their rated voltage. Select the generator G₁ ratings as base values. Choose the fault location in bus 3. And give the bellow answer For a symmetrical three phase fault on the bus 3 1. Calculate the fault current in ampere and fault power in MVA and the fault current contribution from the generator connected to the bus 3.arrow_forward
- A 50 MVA, 11 KV three-phase alternator was subjected to a different types of faults. The fault current REN Art (1) 1870 A. for three-phase fault. (ii) 2590 A. for L-L fault. *VE ve. -Ve AV19 (iii)4130 A. for L-G fault. The alternator neutral is solidly grounded. Find the three sequence reactance's of the alternator. X., X., X +V., -ve, vearrow_forward13. _______ current attempts to return to the source over any available conductive path.A. DirectB. AlternatingC. Ground-faultD. Arc-faultarrow_forwardDescribe the process of fault current analysis in power systems and its significance in protecting electrical equipment from damage.arrow_forward
- A 3-phase, 33-MVA, 44-kV alternator has a substransient reactance of 7%. A 3-phase short circuit occurs at its terminals. Determine the fault current. Use the alternator rating as base values. Round your answer to 2 decimal places.arrow_forwardIf an unsymmetrical fault occurs on phase C of a transmission line, what would make the fault symmetrical? A. if phase C of the transmission line opens B. If phases A and B become faulted C. If two different faults occur on phas a and barrow_forwardWhat are electrical techniques used for failure analysisarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education

Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education

Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON

Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,