Use the UT33B multimeter and check the voltage of the batteries and the resistance of, light bulb and resistors supplied. - Voltage of the battery is measured to be 1608 mV, The scale used to measure voltage is 2000mV on the UT33B multimeter - Resistance of the bulb is measured to be 0.24 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter - Resistance of the resistor1 (R1) is measured to be 15.2 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter - Resistance of the resistor2 (R2) is measured to be 27.2 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter i) Justify your selection of the scale used. ii) Quote all results in the standard form i.e. must include uncertainty. iii) For the resistors how does your measurement compare to the nominal value. Clearly explain how you established if there was an agreement or not.
Protection System
A system that protects electrical systems from faults by isolating the problematic part from the remainder of the system, preventing power from being cut from healthy elements, improving system dependability and efficiency is the protection system. Protection devices are the equipment that are utilized to implement the protection system.
Predictive Maintenance System
Predictive maintenance technologies are designed to assist in determining the state of in-service equipment so that maintenance can be scheduled. Predictive maintenance is the application of information; proactive maintenance approaches examine the condition of equipment and anticipate when it should maintain. The purpose of predictive maintenance is to forecast when equipment will fail (depending on a variety of parameters), then prevent the failure through routine and corrective maintenance.Condition monitoring is the continual monitoring of machines during process conditions to maintain optimal machine use, which is necessary for predictive maintenance. There are three types of condition monitoring: online, periodic, and remote. Finally, remote condition monitoring allows the equipment observed from a small place and data supplied for analysis.
Preventive Maintenance System
To maintain the equipment and materials on a regular basis in order to maintain those running conditions and reduce unnecessary shutdowns due to unexpected equipment failure is called Preventive Maintenance (PM).
Use the UT33B multimeter and check the voltage of the batteries and the resistance of, light bulb and resistors supplied.
- Voltage of the battery is measured to be 1608 mV, The scale used to measure voltage is 2000mV on the UT33B multimeter
- Resistance of the bulb is measured to be 0.24 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter
- Resistance of the resistor1 (R1) is measured to be 15.2 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter
- Resistance of the resistor2 (R2) is measured to be 27.2 ohm, The scale used to measure resistance is 200 ohm on the UT33B multimeter
i) Justify your selection of the scale used.
ii) Quote all results in the standard form i.e. must include uncertainty.
iii) For the resistors how does your measurement compare to the nominal value. Clearly explain how you established if there was an agreement or not.