Three symmetrical three-phase loads are connected in parallel. Load 1 is connected in Y with an impedance of 400 + j300Ω / φ, load 2 is connected in with with an impedance of 2400 - j1800Ω / φ and load 3 is evaluated at 172.8 + j2203.2 kVA. Loads are supplied from a distribution line with an impedance of 2 + j16Ω / φ. Size of the voltage between the line and the neutral conductor at the end of the charge the line is 24√3 kV. The operating frequency is 50 Hz. (a) Calculate the line currents and the phase currents of the loads. (b) Calculate the total complex power at the receiving end of the system. (c) Calculate the total complex power at the transmitting end of the line. (d) Calculate the values ​​of the compensation capacitors which are connected from the line to the neuron at the load end of the system so that the power factor at the load end reaches pf ≥ 0.98. (e) What if the capacitors are connected from one line to another? What would be the best choice for compensation, the capacitors connected in Y or ∆? Explain. (f) What is the power factor at the sending end of the line?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter6: Power Flows
Section: Chapter Questions
Problem 6.61P
icon
Related questions
Question

Can you please solve the d e f parts?

Three symmetrical three-phase loads are connected in parallel. Load 1 is connected in Y with an impedance of 400 + j300Ω / φ, load 2 is connected in with with an impedance of 2400 - j1800Ω / φ and load 3 is evaluated at 172.8 + j2203.2 kVA. Loads are supplied from a distribution line with an impedance of 2 + j16Ω / φ. Size of the voltage between the line and the neutral conductor at the end of the charge the line is 24√3 kV. The operating frequency is 50 Hz.
(a) Calculate the line currents and the phase currents of the loads.
(b) Calculate the total complex power at the receiving end of the system.
(c) Calculate the total complex power at the transmitting end of the line.
(d) Calculate the values ​​of the compensation capacitors which are connected from the line to the neuron at the load end of the system so that the power factor at the load end reaches pf ≥ 0.98.
(e) What if the capacitors are connected from one line to another? What would be the best choice for compensation, the capacitors connected in Y or ∆? Explain.
(f) What is the power factor at the sending end of the line?

Expert Solution
steps

Step by step

Solved in 7 steps with 7 images

Blurred answer
Knowledge Booster
Analysis of Single Phase and Three Phase System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning