A three-phase 60Hz line with a flat horizontal spacing uses conductors with a GMR of 0.0112 m, diameter of 3.4 cm, and a spacing between adjacent conductors of 11 m. The inductive reactance per phase in ohms per kilometer is what?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Three conductors of a 3-phase overhead line are arranged in a horizontal plane in the order a-b-c, distance between a and b is 12 m, b and c is spaced 12 m apart. The diameter of each line conductor is 2 cm. Calculate the Capacitance per phase per km (C1) for this arrangement. Calculate Capacitance per phase per km(C2) if the spacing between the conductors are reduced by 1/4th of the given spacing. Capacitance in per Phase per Km for Arrangement 1 (C1) Capacitance in per phase per km for Arrangement 2 (C2)arrow_forwardThe Cost OF Single phase overhead feeder is OMR q Per KM(a is area of cross section in sq mm) and the intrest and depre Ciation Chargs onfeeder omical carrent density are 7Y. defermain to use for the most econor requiring Full load current of 27% of the 12 baisa is year. The Cost per unit ass ume resistance of Im lenahth length and I mm² secfion of Conductor as 1/32 find Current densi ty =?arrow_forwardQ2(a) Figure Q2(a) shows the spacing of a double circuit 3-phase overhead line. The phase sequence is UVW and the line is completely transposed. i) Critically assess the advantages of double circuit line over single circuit line Calculate the inductance per phase for 500 meter length of line using Table 2(a) data for the Figure Q2(a). Table 2(a) GMR of the line 0.01m Distance a-b' 6.m Distance c-c' 8.3m a b Figure Q2(a)arrow_forward
- A two conductor single phase line operates at 55 Hz. The diameter of each conductor is 25 mm and the spacing between the conductor is 3 m. Calculate i) the inductance of each conductor per km ii) the loop inductance of the line per km iii) the inductive reactance per km, and iv) the loop inductance per km of the line when the conductor material is steel of relative permeability 55.arrow_forwardSubject Power Transmission and Distributionarrow_forwardQ2: A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight meter. The capacitance in µF/km without effect -1 of ground is إجابتك The capacitance in µF/km with effect of -2 ground isarrow_forward
- (a) A single phase line has two parallel conductors and the circumference of each conductor is 12n mm. The total loop inductance for 150 km line is 363.4858 mH. The line is made of aluminium with resistivity equal to 2.65×10-8 2.m and temperature coefficient of 0.00429 per °C. (i) Evaluate the spacing between conductors. (ii) Find the total loop resistance of the line.arrow_forwardQ1: A 1-ph, 220 V, 50 Hz overhead line has a distance of 4 m between its .conductors and 7 m above the ground. The diameter of each conductor is 15 mm The capacitance between conductors (in pF) for a length of 50 km .2 *.----- without the effect of ground is (2) uhi هذا السؤال مطلوب The capacitance between conductors (in uF) for a length of 50 km with .1 * .----- the effect of ground is (2) Jahi هذا السؤال مطلوب (2) Jihi * The charging current (in Ampere) without the effect of ground is .3arrow_forwardA Three-phase transposed line is composed of one conductor per phase with flat horizontal spacing of D-14 meters, as shown in the below figure. The conductors have a diameter of 2.6 cm and a GMR of 1.012 cm. Find the capacitance per phase per kilometer of the line a D D 2D Select one: a 0.0088 microF/Km Ob. 0.0077 microF/Km Oc1455 microF/Km Od. None of thesearrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,