The line diagram is of a standard forward/reverse/stop pushbutton station for forwarding and reversing a motor. Included in the circuit are mechanical and auxiliary contact interlocking. Also included are a forward overtravel limit switch to stop the motor in forward and a reverse overtravel limit switch to stop the motor in reverse. Overload protection is common to both forward and reverse directions. Complete the wiring diagram based on the line diagram. Do not make any wire splices or additional terminal connections on the wiring diagram (notice how they make multiple connections in the power circuit). All connections must run from terminal screw to terminal screw
complete the wiring diagram based on the line diagram. Do not make any wires splices or additional terminal connections on the wiring diagram. All connections must run from terminal screw to terminal screw
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 2 images

Knowledge Booster
Similar questions
- What are typical uses for control relaysarrow_forward6.a. Arcing in manual starters is eliminated by the use ofA. overload relays.B. nonconductive contacts.C. blowout coils.D. spring-loaded handles.6.b. Chattering of AC contactors is prevented byA. blowout coils.B. air gaps.C. secondary windings.D. shading poles.arrow_forward20.a. A capacitive sensor is used to detect the presence of _______ objects.A. ferrousB. nonmovingC. nonconductiveD. magnetic20.b. A three-phase motor can be made to run backwards byA. connecting a resistor in series with the armature.B. reversing the control voltage connections.C. reversing three of its power leads.D. reversing two of its power leads.arrow_forward
- Why DMMs do not suffer as much meter loading as a moving coil meter?arrow_forwardWhich of the following components would not be connected in series with the contactorcoil A. Compressor internal overload switchB. Low pressure safety switchC. High pressure safety switchD. High discharge temperature safety switcharrow_forwardTechnician A says when testing the voltage output, if the charging voltage is too high, the cause could be an open field wire from the regulator. Technician B says a loose or glazed drive belt could be the cause of too high charging voltage. Who is correct? A only B only Both A and B Neither A or B Technician A says that poor connection at the generator output wire can cause charging systems problems. Technician B says that many charging system circuits contain a circuit protection device. Who is correct? A only B only Both A and B Neither A or Barrow_forward
- In the context of power system protection, what are the various types of relays and their functions in detecting faults and ensuring system safety?arrow_forwardAll overload relays have two main components. What are these two components?arrow_forwardQuestion 2 (a) Figure Q2(a) shows the percentage differential relay used for the protection of an alternator winding. The relay has minimum pickup current of 0.15 A and a percentage slope of 12%. A high resistance ground fault occurs near the grounded neutral end of the generator winding with the current distribution as shown in Table Q2(a). Identify with reason whether the relay will operate. I I CB wiłu 400/5 400/5 iz mhu Figure Q2(a) Table Q2(a) Student Name I2 (A) ID (A) 370 300arrow_forward