Transcribed Image Text:The following data for a 1250 kVA, 0.8 p.f., 50 Hz, 3300 V, 300 rpm star connected alternator is available :
Stator turns per phase
150
Field turns per pole
Effective area per pole
Airgap length at pole centre
Field current for full load short circuit current
ATS per pole for iron portion
Assuming sinusoidal flux distribution, estimate the values of short circuit ratio and synchronous reactance.
=
= 60
= 0.09 m²
= 5.5 mm
= 80 A
= 20% of airgap
Expert Solution

arrow_forward
Step 1
Step by stepSolved in 2 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 60 Hz alternator stator is wye connected with each phase winding having 24 turns of wire. The rotor is supplying 0.103 Wb of flux in the center of pole face. What is the rms value of the output voltage if measured line to neutralarrow_forward9.a. If a 33% load increase is suddenly applied to an alternator having a 25% reactance, the initial voltagedrop will be aboutA. 8.25%B. 13.25%C. 3.3%D. 2.5%9.b. At what speed must a four-pole alternator operate to produce a 100-cps alternating voltage?A. 3000 rpmB. 12,000 rpmC. 1500 rpmD. 6000 rpmarrow_forwardA synchronous generator runs at 250 rpm and generates at 50-Hz. There are 216 slots, each containing 5 conductors arranged in a full-pitched winding for 3-phase star connection. All the conductors of each phase are in series and the flux per pole at no-load sinusoidally distributed over the pole pitch is 30 mWb. Find the emf induced in each phase winding and the terminal voltage.arrow_forward
- How can the phase rotation of one alternator be changed in relationship to the other alternator?arrow_forwardCalculate the voltage per phase for a 1500 rpm, 4 pole alternator having a double layer winding with 16 turns per coil. The slots per pole phase are 8 and the coil span is 20 slots. The phase spread is 60o and the flux per pole is 25.8 milli webers.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,

Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON

Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning

Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education

Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education

Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON

Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,