Select the more suitable answer for the following: (note: Write only the suitable letter clearly. Any misleading answer will be discarded) 1- Misreading and incorrect adjustment of an instrument and incorrect adjustment of an instrument are considered as: a-Systematic errors. c- Instrumental errors b-Gross errors. d-Random errors. 2- The temperature coefficient of the thermocouple transducer is: a- Positive c- Depends on the combination of the metal used. 3. Strain gauge is a........... a- Active device and converts mechanical displacement into a change of resistance. b- Passive device and converts electrical displacement into a change of resistance. c- Passive device and converts mechanical displacement into a change of resistance. d- Active device and converts electrical displacement into a change of resistance. 4- An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured is 5 A. The limiting error is........ a- 2% c- 4% a- LVDT c- Isolation amplifier b- Negative. d- Neutral. b- 2.5% d- 5% 5- To overcome the common mode voltage(Vcm) on both instrument differential input, we must use: b- Instrumentation amplifier d-Current mode amplifier 6- The operation of a relaxation oscillator is based on.... a-The charging and discharging of a capacitor. b- a highly selective resonant circuit.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Select the more suitable answer for the following: (note: Write only the suitable letter
clearly. Any misleading answer will be discarded)
1- Misreading and incorrect adjustment of an instrument and incorrect adjustment of an
instrument are considered as:
a-Systematic errors.
c- Instrumental errors
b-Gross errors.
d-Random errors.
2- The temperature coefficient of the thermocouple transducer is:
a- Positive
c- Depends on the combination of the metal used.
3. Strain gauge is a...........
a- Active device and converts mechanical displacement into a change of resistance.
b- Passive device and converts electrical displacement into a change of resistance.
c- Passive device and converts mechanical displacement into a change of resistance.
d- Active device and converts electrical displacement into a change of resistance.
4- An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current
measured is 5 A. The limiting error is........
a- 2%
c- 4%
a- LVDT
c- Isolation amplifier
b- Negative.
d- Neutral.
b- 2.5%
d- 5%
5- To overcome the common mode voltage(Vcm) on both instrument differential input, we must
use:
b- Instrumentation amplifier
d-Current mode amplifier
6- The operation of a relaxation oscillator is based on...
a-The charging and discharging of a capacitor.
b- a highly selective resonant circuit.
Transcribed Image Text:Select the more suitable answer for the following: (note: Write only the suitable letter clearly. Any misleading answer will be discarded) 1- Misreading and incorrect adjustment of an instrument and incorrect adjustment of an instrument are considered as: a-Systematic errors. c- Instrumental errors b-Gross errors. d-Random errors. 2- The temperature coefficient of the thermocouple transducer is: a- Positive c- Depends on the combination of the metal used. 3. Strain gauge is a........... a- Active device and converts mechanical displacement into a change of resistance. b- Passive device and converts electrical displacement into a change of resistance. c- Passive device and converts mechanical displacement into a change of resistance. d- Active device and converts electrical displacement into a change of resistance. 4- An ammeter of 0-25 A range has a guaranteed accuracy of 1% of full scale reading. The current measured is 5 A. The limiting error is........ a- 2% c- 4% a- LVDT c- Isolation amplifier b- Negative. d- Neutral. b- 2.5% d- 5% 5- To overcome the common mode voltage(Vcm) on both instrument differential input, we must use: b- Instrumentation amplifier d-Current mode amplifier 6- The operation of a relaxation oscillator is based on... a-The charging and discharging of a capacitor. b- a highly selective resonant circuit.
Expert Solution
steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Knowledge Booster
Feedback amplifier
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,