Question
Refer to the attached plan and section
to answer the succeeding questions
12mm THK. SLAB COVER WITH 10mmo RSB.
SPACED E EVERY 200mm 0.C. B.W.
3000
1200
600
600
150
INLET p
MANHO
MANHOLE
150
16mmo RSB AT EVERY
CORNER AND CHB JOINTS.
PLAN
12mmo BAR
LIFTING HANDLE
12mm THK. SLAB COVER WITH 12mmo RSB,
SPACED EVERY 250mm O.C., B.W.
3000
1200
600
600
E नि्॥
120
300mm. AIR SPACE
INLET
WATER LEVEL
WATER LEVEL
WATER LEVEL
OUTLET
JO PVC PPE AND FITTINGS
DIGESTIVE
LEACHING
CHAMBER
LEACHING
CHAMBER
CHAMBER
USE 5 CHB WITH 10mme
VERTICAL BARS SPACED
400mm AND HORRONTAL
BARS O EVERY 3 LAYERS.
1:10SLOPE
150
1Smm THK. SLAB ON FILL WITH 12mmo RSB.
SPACED E EVERY 250mm O.C., B.W.
How thick is the Required
plastering on the Septic tank
walls from the given drawings
O 1" each face
O 1/2" each face
O 1/4" each face
O No Plastor reuirod
2070
000
000L
150
expand button
Transcribed Image Text:Refer to the attached plan and section to answer the succeeding questions 12mm THK. SLAB COVER WITH 10mmo RSB. SPACED E EVERY 200mm 0.C. B.W. 3000 1200 600 600 150 INLET p MANHO MANHOLE 150 16mmo RSB AT EVERY CORNER AND CHB JOINTS. PLAN 12mmo BAR LIFTING HANDLE 12mm THK. SLAB COVER WITH 12mmo RSB, SPACED EVERY 250mm O.C., B.W. 3000 1200 600 600 E नि्॥ 120 300mm. AIR SPACE INLET WATER LEVEL WATER LEVEL WATER LEVEL OUTLET JO PVC PPE AND FITTINGS DIGESTIVE LEACHING CHAMBER LEACHING CHAMBER CHAMBER USE 5 CHB WITH 10mme VERTICAL BARS SPACED 400mm AND HORRONTAL BARS O EVERY 3 LAYERS. 1:10SLOPE 150 1Smm THK. SLAB ON FILL WITH 12mmo RSB. SPACED E EVERY 250mm O.C., B.W. How thick is the Required plastering on the Septic tank walls from the given drawings O 1" each face O 1/2" each face O 1/4" each face O No Plastor reuirod 2070 000 000L 150
What is the MINIMUM number of
CHB units required for the
Septic Tank EXTERIOR WALLS? *
Your answer
What is the minimum number of
CHB units required for the
partition wall
Your answer
How many 6m length x D10mm
rebars are required to support
the EXTERIOR WALL, of the
septic tank
expand button
Transcribed Image Text:What is the MINIMUM number of CHB units required for the Septic Tank EXTERIOR WALLS? * Your answer What is the minimum number of CHB units required for the partition wall Your answer How many 6m length x D10mm rebars are required to support the EXTERIOR WALL, of the septic tank
Expert Solution
Check Mark
Knowledge Booster
Background pattern image
Civil Engineering
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Text book image
Structural Analysis
Civil Engineering
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:Cengage,
Text book image
Structural Analysis (10th Edition)
Civil Engineering
ISBN:9780134610672
Author:Russell C. Hibbeler
Publisher:PEARSON
Text book image
Principles of Foundation Engineering (MindTap Cou...
Civil Engineering
ISBN:9781337705028
Author:Braja M. Das, Nagaratnam Sivakugan
Publisher:Cengage Learning
Text book image
Fundamentals of Structural Analysis
Civil Engineering
ISBN:9780073398006
Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:McGraw-Hill Education
Text book image
Sustainable Energy
Civil Engineering
ISBN:9781337551663
Author:DUNLAP, Richard A.
Publisher:Cengage,
Text book image
Traffic and Highway Engineering
Civil Engineering
ISBN:9781305156241
Author:Garber, Nicholas J.
Publisher:Cengage Learning