: The power input to a 500 V, 50 Hz, 6 pole, 3-phase induction motor running at 975
r.p.m. is 40 kW. The stator losses are 1 kW and friction and windage losses total 2 kW.
Calculate: i) The slip. ii) The rotor copper loss. iii) shaft power and iv) The efficiency.