QUESTIONS 1. Which of the following does not run a competent person scheme? a) NAPIT b) ECA c) NICEIC d) ELECSA 2. The Building Regulations came into force in... a) 2001 b) 2000 c) 2010 d) 1984 3. How many diameters apart should holes be drilled in the same joist? a) 3 b) 4 c) 5 d) 6

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.34MCQ: Consider Figure 3.25 of the text for a transformer with off-nominal turns ratio. (i) The per-unit...
icon
Related questions
Question
QUESTIONS
1. Which of the following does not run a competent person scheme?
a) NAPIT
b) ECA
c) NICEIC
d) ELECSA
2. The Building Regulations came into force in...
a) 2001
b) 2000
c) 2010
d) 1984
3. How many diameters apart should holes be drilled in the same joist?
a) 3
b) 4
c) 5
d) 6
4. What year was Part P first published?
a) 2002
b) 2003
c) 2004
d) 2005
5. According to Part M, what is the minimum load capacity of a lift in a leisure centre?
a) 300 kg
b) 400 kg
c) 500 kg
d) 600 kg
6. Smoke alarms in domestic properties are classed as category...
a) A
b) B
c) C
d) D
7. A person carrying out electrical work that fails to comply with building regulations can be fined up
to...
a) £1,000
b) £2,500
c) £4,000
d) £5,000
8. Which is not classed as a Part P special location?
a) Kitchen
b) Sauna
c) Home office
d) Bathroom
9. A dwelling must have a smoke alarm within how many metres of each habitable room?
a) 6 metres.
b) 6.5 metres
c) 7 metres
d) 7.5 metres
10. How many approved parts are there?
a) 13
b) 14
c) 15
d) 16
Transcribed Image Text:QUESTIONS 1. Which of the following does not run a competent person scheme? a) NAPIT b) ECA c) NICEIC d) ELECSA 2. The Building Regulations came into force in... a) 2001 b) 2000 c) 2010 d) 1984 3. How many diameters apart should holes be drilled in the same joist? a) 3 b) 4 c) 5 d) 6 4. What year was Part P first published? a) 2002 b) 2003 c) 2004 d) 2005 5. According to Part M, what is the minimum load capacity of a lift in a leisure centre? a) 300 kg b) 400 kg c) 500 kg d) 600 kg 6. Smoke alarms in domestic properties are classed as category... a) A b) B c) C d) D 7. A person carrying out electrical work that fails to comply with building regulations can be fined up to... a) £1,000 b) £2,500 c) £4,000 d) £5,000 8. Which is not classed as a Part P special location? a) Kitchen b) Sauna c) Home office d) Bathroom 9. A dwelling must have a smoke alarm within how many metres of each habitable room? a) 6 metres. b) 6.5 metres c) 7 metres d) 7.5 metres 10. How many approved parts are there? a) 13 b) 14 c) 15 d) 16
11. What is the minimum height in a new building that a telephone socket should be fitted?
a) 350 mm
b) 400 mm
c) 450 mm
d) Any height you want
12. In an internal bathroom, a natural ventilation fan should have a run on time of...
a) 15 minutes
b) 20 minutes
c) 25 minutes
d) 30 minutes
13. What is not a notifiable work?
a) Changing a consumer unit
b) Install a cooker circuit
c) Changing a pendant into downlights
d) Garden lighting
14. What size water heater requires its own electrical circuit?
a) 10 litres
b) 15 litres
c) 20 litres
d) 25 litres
15. How often would you be inspected as part of the competent person scheme?
a) Every 6 months
b) Once a year
c) Once every 2 years
d) Only on joining
16. What is the minimum distance a hole should be drilled from the top or bottom of a joist?
a) 50 mm
b) 60 mm
c) 100 mm.
d) 150 mm
17. Approved Part B needs to be complied with if no storey in a house exceeds how many square
metres?
a) 50
b) 100
c) 200
d) 250
18. What is the maximum notch depth allowed?
a) 0.07 x joist depth
b) 0.25 x joist depth
c) 0.125 x joist depth
d) 0.4 x joist depth
Transcribed Image Text:11. What is the minimum height in a new building that a telephone socket should be fitted? a) 350 mm b) 400 mm c) 450 mm d) Any height you want 12. In an internal bathroom, a natural ventilation fan should have a run on time of... a) 15 minutes b) 20 minutes c) 25 minutes d) 30 minutes 13. What is not a notifiable work? a) Changing a consumer unit b) Install a cooker circuit c) Changing a pendant into downlights d) Garden lighting 14. What size water heater requires its own electrical circuit? a) 10 litres b) 15 litres c) 20 litres d) 25 litres 15. How often would you be inspected as part of the competent person scheme? a) Every 6 months b) Once a year c) Once every 2 years d) Only on joining 16. What is the minimum distance a hole should be drilled from the top or bottom of a joist? a) 50 mm b) 60 mm c) 100 mm. d) 150 mm 17. Approved Part B needs to be complied with if no storey in a house exceeds how many square metres? a) 50 b) 100 c) 200 d) 250 18. What is the maximum notch depth allowed? a) 0.07 x joist depth b) 0.25 x joist depth c) 0.125 x joist depth d) 0.4 x joist depth
Expert Solution
steps

Step by step

Solved in 5 steps with 3 images

Blurred answer
Knowledge Booster
Star delta conversion
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning