Q2.The single line diagram of a three phase power system is shown in Fig.(1). Draw an impedance diagram showing all impedances in per unit. Also, find the terminal voltage of the generator when motor No.1 draws 4MW at 0.95 power factor lagging at 6 kV terminal voltage and motor 2 is not loaded?. The data of the system elements are given as follows: G: 15 MVA, 13.2kV, X-0.1p.u. Mı: 2 MVA, 6.6kV, X=0.08 p.u. M2: 5 MVA, 11kV, X-0.12 p.u. T: 10 MVA, 13.8/138 kV,X=0.1 p.u. T2: Bank of single units each 1 MVA, 7/76.2 kV, X-0.09 p.u. T3: 5 MVA, 13.2/132kV,X=0.12 p. Line: (20+j100) 0 Select a base power of 50 MVA and a base of 15kV in the generator zone

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.41P
icon
Related questions
Question
i need ans within 9 minutes with draw happy emoji in the end my best wishes ton
Q2.The single line diagram of a three phase power system is shown in Fig.(1). Draw an impedance diagram
showing all impedances in per unit. Also, find the terminal voltage of the generator when motor No.1 draws
4MW at 0.95 power factor lagging at 6 kV terminal voltage and motor 2 is not loaded?. The data of the
system elements are given as follows:
G: 15 MVA, 13.2kV, X-0.1p.u.
Mi: 2 MVA, 6.6kV, X-0.08 р.u.
M2: 5 MVA, 11kV, X-0.12 p.u.
T1: 10 MVA, 13.8/138 kV,X=0.1 p.u.
T2: Bank of single units each 1 MVA, 7/76.2 kV, X-0.09 p.u.
T3: 5 MVA, 13.2/132kV,X=0.12 p.
Line: (20+j100) O
Select a base power of 50 MVA and a base of 15kV in the generator zone
E
T1
Line
T2
N
T3
N
M2
Fig.(1)
Y
Emm,
Transcribed Image Text:Q2.The single line diagram of a three phase power system is shown in Fig.(1). Draw an impedance diagram showing all impedances in per unit. Also, find the terminal voltage of the generator when motor No.1 draws 4MW at 0.95 power factor lagging at 6 kV terminal voltage and motor 2 is not loaded?. The data of the system elements are given as follows: G: 15 MVA, 13.2kV, X-0.1p.u. Mi: 2 MVA, 6.6kV, X-0.08 р.u. M2: 5 MVA, 11kV, X-0.12 p.u. T1: 10 MVA, 13.8/138 kV,X=0.1 p.u. T2: Bank of single units each 1 MVA, 7/76.2 kV, X-0.09 p.u. T3: 5 MVA, 13.2/132kV,X=0.12 p. Line: (20+j100) O Select a base power of 50 MVA and a base of 15kV in the generator zone E T1 Line T2 N T3 N M2 Fig.(1) Y Emm,
Expert Solution
steps

Step by step

Solved in 3 steps with 3 images

Blurred answer
Knowledge Booster
Logic Gate and Its Application
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning