Q1: Choose the correct answer for the following: 1- While selecting the location of an intake for collecting surface water, the factor considered, is a-The intake point should be near as far as possible to the treatment plant b-The intake point should be in purer zone of the water source c-The intake point should be upstream of the point of disposal of waste water d-The intake point in meandering rivers should be on concave banks e-All the above 2- A centrifugal pump is required to be primed (checked for suitable location) before starting if it is located at higher level than water level of reservoir b-at lower level than water level of reservoir c- both (a) and (b) d- neither (a) nor (b). v² 3-The formula h₁ = f for the head loss in conduits is generally known as 2g a- Hazen-William's formula b- Manning's formula Darcy-Weisbach formula d- Nikuradse formula.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
I need the answer as soon as possible
Q1: Choose the correct answer for the following:
1- While selecting the location of an intake for collecting surface water, the factor considered, is
a-The intake point should be near as far as possible to the treatment plant
b-The intake point should be in purer zone of the water source
c-The intake point should be upstream of the point of disposal of waste water
d-The intake point in meandering rivers should be on concave banks
e-All the above
2- A centrifugal pump is required to be primed (checked for suitable location) before starting if it is located
at higher level than water level of reservoir b-at lower level than water level of reservoir
c- both (a) and (b)
d- neither (a) nor (b).
1v²
3-The formula h₁ = f for the head loss in conduits is generally known as
d2g
a- Hazen-William's formula
b- Manning's formula
Darcy-Weisbach formula
d- Nikuradse formula.
4- In order to overcome large system headloss
a-Only one pump can be used
b-More than one pump connected in parallel are used
d-None of these
c-More than one pump connected in series are used
5- The pipe connected to low lifting pump returning to the strainer called:
a-Gravity pipe
b-Wash pipe
e-Distributed pipe
d-Chamber
Transcribed Image Text:Q1: Choose the correct answer for the following: 1- While selecting the location of an intake for collecting surface water, the factor considered, is a-The intake point should be near as far as possible to the treatment plant b-The intake point should be in purer zone of the water source c-The intake point should be upstream of the point of disposal of waste water d-The intake point in meandering rivers should be on concave banks e-All the above 2- A centrifugal pump is required to be primed (checked for suitable location) before starting if it is located at higher level than water level of reservoir b-at lower level than water level of reservoir c- both (a) and (b) d- neither (a) nor (b). 1v² 3-The formula h₁ = f for the head loss in conduits is generally known as d2g a- Hazen-William's formula b- Manning's formula Darcy-Weisbach formula d- Nikuradse formula. 4- In order to overcome large system headloss a-Only one pump can be used b-More than one pump connected in parallel are used d-None of these c-More than one pump connected in series are used 5- The pipe connected to low lifting pump returning to the strainer called: a-Gravity pipe b-Wash pipe e-Distributed pipe d-Chamber
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Asphalt binders and mixtures
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning