Q.1. A refrigeration process with interstage cooling uses refrigerant HFC-134a, and the outlet of the condenser is to be saturated liquid at 40°C. Refer to the following figure for stream numbers in your solution. The pressure of the flash chamber and the intermediate pressure between compressors is to be 290 kPa. The evaporator is to operate at -20°C and the outlet is to be saturated vapor. The flowrate of stream 1 is 23 kg/h. The flash chamber may be considered adiabatic. The compressors may be considered to be 80% efficient. a) What is the power input required to the first compressor? b) What are the flowrates of streams 6 and 7? c) What is the enthalpy of stream 4? Hot Side 6. Condenser 2nd Stage Compressor Throttle Valve 7 Flash Vapor Phase Only. Chamber 1st Stage Compressor Throttle Valve Evaporator Cold Side

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter40: Typical Operating Conditions
Section: Chapter Questions
Problem 9RQ: The evaporator design temperature may in some cases operate at a slightly ____(higher or lower)...
icon
Related questions
Question
Q.1. A refrigeration process with interstage cooling uses refrigerant HFC-134a, and the outlet of
the condenser is to be saturated liquid at 40°C. Refer to the following figure for stream numbers
in your solution. The pressure of the flash chamber and the intermediate pressure between
compressors is to be 290 kPa. The evaporator is to operate at -20°C and the outlet is to be saturated
vapor. The flowrate of stream 1 is 23 kg/h. The flash chamber may be considered adiabatic. The
compressors may be considered to be 80% efficient.
a) What is the power input required to the first compressor?
b) What are the flowrates of streams 6 and 7?
What is the enthalpy of stream 4?
Hot Side
6
5
Condenser
2nd Stage
Compressor
Throttle Valve
7
Flash
Chamber
Vapor Phase Only
1st Stage
Compressor
8
Throttle Valve
Evaporator
1
2
Cold Side
Transcribed Image Text:Q.1. A refrigeration process with interstage cooling uses refrigerant HFC-134a, and the outlet of the condenser is to be saturated liquid at 40°C. Refer to the following figure for stream numbers in your solution. The pressure of the flash chamber and the intermediate pressure between compressors is to be 290 kPa. The evaporator is to operate at -20°C and the outlet is to be saturated vapor. The flowrate of stream 1 is 23 kg/h. The flash chamber may be considered adiabatic. The compressors may be considered to be 80% efficient. a) What is the power input required to the first compressor? b) What are the flowrates of streams 6 and 7? What is the enthalpy of stream 4? Hot Side 6 5 Condenser 2nd Stage Compressor Throttle Valve 7 Flash Chamber Vapor Phase Only 1st Stage Compressor 8 Throttle Valve Evaporator 1 2 Cold Side
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 3 steps with 3 images

Blurred answer