Problem statement: A three phase 60- Hz, 550- kV transmission line is 300 km long. The line parameter per phase per unit length are found to be r-0.016 O/km L-0.97 mH/km C-0.0115 uF/km
Q: What is the difference between balanced and unbalanced line transmission lines, show the difference…
A:
Q: The ABCD constants of a lossless three-phase, 500-kV transmission line are A=D-086 B-130.2 (C)…
A: Voltage regulation: It tells how much voltage fluctuation is at the receiving end terminal. It is…
Q: A 230-kV, 100-km, 60-Hz three-phase overhead transmission line with a rated current of 900 A/phase…
A: Transmission line- The term transmission line refers to both overhead and underground cables. An…
Q: 13.) In practice, what would happen to the transmission line voltage when it is heavily loaded and…
A: We are authorized to answer one question at a time since you have not mentioned which question you…
Q: Vo coswt Z, = 50 10
A: V(L) = V+ejBL [1+τej(ϕL-2βL)] I(L) = V+ejBLZo [1-τej(ϕL-2βL)]
Q: 2. a) Draw nominal t model of Transmission Line.
A:
Q: A 3-phase transmission line consists of 2 cm radius conductors spaced symmetrically 3 metres apart,…
A:
Q: Q1/ Explain in detail VOLTAGE DROP / RISE IN TRANSMISSION LINE With mathematical examples
A:
Q: Question 03: What is the difference between balanced and unbalanced line transmission lines, show…
A: We need to state the differences between balanced and unbalanced transmission lines.
Q: TUTORIAL PROBLEMS 1. A 3-phase overhead transmission line has a total series impedance per phase of…
A:
Q: À three phase 220KV, 50HZ transmission line supplies a power of 100MW at a power factor of 0.8 lag…
A:
Q: Example: A 3-phase overhead transmission line has a total series impedance per phase of 200 280°…
A:
Q: vii. RCC poles... R... .C... . used to support transmission tower ix. Calculate charring current per…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: Q3/ A 3-phase, 50HZ, 150 km line has a resistance, inductive reactance and capacitive shunt…
A:
Q: What is the difference between balanced and unbalanced line transmission lines, show the difference…
A:
Q: A three-phase 60-hz transmission line has its conductors arranged in a triangular formation so that…
A: The conductor used is ACSR Rook, The ACSR Rook is a concentrical stranded conductor with one or more…
Q: A single-phase transmission line is composed of two solid round conductors having a radius of 0.45cm…
A: In this question we need to find the value of the inductance per conductor and the inductance of…
Q: A short, three-phase subtransmission line has an impedance of 1.5 + j2.4 ohms/conductor. If the line…
A:
Q: A 69-kV, three-phase short transmission line is 16 km long. The line has a per phase series…
A:
Q: The arrangement of conductors of a single-phase transmission line is shown in Figure wherein the…
A: According to the question we have to calculate the inductive reactance of the line.
Q: A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4…
A: 1..>>Capacitance of line without effect of ground Radius of conductor is 0.4cm Distance…
Q: 22 A three-phase, 60-Hz transmission line is 100 mi long and has flat horizon pacing. Each phase…
A:
Q: Design a ‘π’ equivalent circuit for 320 km long 3-φ, 50 Hz transmission line. The line is composed…
A:
Q: Q3. For the Figure below, find the inductance per km of a transposed double circuit three- phase…
A: Given, r=1.2 cm d1=7.5 mD=42+0.752=4.07 md2=42+7.5+0.752=9.17 md3=82+7.52=10.97 md4=7.5+0.75+0.75=9…
Q: A 40-km, 220-kV, 60-Hz three-phase overhead transmission line has a per-phase resistance of 0.15…
A:
Q: A 69-kV, three phase short transmission line is 16km long. The line has a per phase series impedance…
A: We need to determine the sending end voltage, voltage regulation, the sending end power, and…
Q: In a short transmission line resistance and inductance is considered as both lumped and distributed…
A: In this we need to tell that given statement is true or false.
Q: The char. impedance of the trans. line is 50-Ohm and the resistance of it is 0.1Ohm/meter. What will…
A: For the distortion less transmission line the attenuation constant is independent of the frequency.…
Q: Question 3: A three-phase, 60-Hz transposed transmission line has a flat horizontal configuration as…
A: Given XL=0.486 Ω/KmXL=2πfLL=XL2πfL=0.4862×3.14×60L=1.289 mH/Km Expression of L…
Q: In short transmission line calculations, the effects of the line capacitance are neglected because…
A:
Q: Example: A 3-phase overhead transmission line has a total series impedance per phase of 200 80° ohms…
A:
Q: A 345-kV transmission line has a series impedance of (4 + j60) Q and a shunt admittance of j2 ×…
A: Given values are - SBase=100MVAVBase=345kVZ=4+j60Y=j2×10-3S
Q: The conductor of a single-phase 60-Hz line is a solid round aluminum wire having a diameter of 0.412…
A: Inductance: It is a passive two-terminal electrical component and measured in Henry (H). When…
Q: A 3 phase, 50 Hz, 150 km line has a resistance, inductive reactance and capacitive shunt admittance…
A:
Q: a) A single-phase transmission line has two parallel conductors m apart, the radius of each…
A: For the two-conductor transmission line system, the loop impedance per m length of the line can be…
Q: A 3-phase overhead transmission line has a total series impedance per phase of 200 ∠80º ohms and a…
A: total shunt admittance per phase, Y=0.0013∠90° Ω-1 total series impedance per phase Z=200∠90° Ω…
Q: TUTORIAL PROBLEMS 1. A 3-phase overhead transmission line has a total series impedance per phase of…
A: The solution can be achieved as follows.
Q: Transmission lines can be categorized on the basis of their length. Explain short transmission line…
A: Trans mission lines can be cateogerized into 3 types on the basis of their lengths 1. Short lines…
Q: 3. A single-phase transmission line has two parallel conductors 3.2 meters apart, radius of each…
A:
Q: The per-phase line loss in a 40 km long transmission line is not to exceed 60 kW while it is…
A:
Q: The voltage regulation of a short transmission line is estimated: O a. Only on Line Inductance O b.…
A: At the point when a transmission line is conveying current, there is a voltage drop in the line…
Q: power of 90+j70 MVA is drawn from the end of a 220 km three-phase transmission line with a voltage…
A:
Q: Question # 03: What is the difference between balanced and unbalanced line transmission lines, show…
A: Given: The difference between the transmission lines which are balanced and unbalanced is asked.
Q: A single-phase transmission line has two parallel conductors 4 m apart, the radius of each conductor…
A: Part i: Write the expression for the external inductance per meter length of one conductor,
Q: 2. A single phase transmission line has two parallel conductors 3 m apart, the diameter of each…
A: Given, Spacing between the conductors = 3 m = 300 cm diameter of conductor = 2.2 cm Radius of each…
Q: A single circuit 60 Hz transmission line. the conductors are Linnet type with flat horizontal…
A: You have asked multiple independent questions. We are authorized to answer one question at a time.…
Q: A three-phase 60-Hz transmission line has its conductors arranged in a triangular formation so that…
A: Given data, D12=D23=25 ft.D12=D23=762 cmD31=42 ftD31=1280.16 cm The approxmiate the diameter of the…
Q: a) Draw nominal - T model of Transmission Line. b) Write ABCD Parameters of the nominal T…
A:
Q: Following are types of Transmission Lines EXCEPT A. Medium Line B. Long Line
A: In this question we will answer of transmission line questions....
Calculate enough parameters to get circle diagram like output power
Please answer in short i will like
Step by step
Solved in 3 steps
- The affect of the earth plane is to slightly increase the capacitance, and as the line height increases, the effect of earth becomes negligible. True FalseOne circuit of a single-phase transmission line is composed of three solid 0.12" radius wires. The return circuit is composed of two 0.15" radius wires. Find the inductance of the complete line in mH/mi. The distance between wires are 40" horizontally and 25" vertically. A. 2.54 mH/mi B. 2.478 mH/mi C. 2.488 mH/mi D. 2.567 mH/mi Provide Clear ExplainationThe conductor of a single-phase 60-Hz line is a solid round aluminum wire having a diameter of 0.412 cm. The conductor spacing is 3 m. Determiņe the inductance of the line in millihenrys per mile. How much of the inductance is due to internal flux linkages? Assume skin effect is negligible.
- One circuit of a single-phase transmission line is composed of three solid 0.5 cm radius wires. The return circuit is composed of two solid 2.5 cm radius wires. The arrangement of conductors is as shown in the following figure. Applying the concept of GMD and GMR, find the inductance of the complete line in mH per km. 5 m 5 m 10 m 5 m Conductor X Conductor Y4/ Which parameter is neglected or ignored in Short Transmission Lines? A. SHUNT CAPACITANCE ONLY B. SERIES CONDUCTANCE AND SHUNT CAPACITANCE C. SHUNT CONDUCTANCE AND SHUNT CAPACITANCE D. SHUNT CONDUCTANCE ONLYQ: 5 Figure below shows a 345 kV double-circuit three-phase transposed line composed of one ACSR, 556, 500-cmil, 26/7 Dove conductor per phase with horizontal conductor arrangement. The conductor has a diameter of 0.927 in and a GMR of 0.3768 in. Find the inductance per phase per km of the line. a b' -8 m 8 m 9 m 8 m 8 m
- A three-phase transposed line is composed of one ACSR Bobolink conductor per phase with a horizontal spacing of 11 meters as shown in the figure. phase with a horizontal spacing of 11 meters as shown in the figure. The conductors have a diameter of 3.625 cm and a RMG of 1.439 cm. Calculate the inductance and capacitance to the neutral of the line.The conductor of a single-phase 60-Hz line is a solid round aluminum wire having a diameter of 0.412 cm. The conductor spacing is 3 m. Determine the inductance of the line in millinery’s per mile. How much of the inductance is due to internal flux linkages? Assume skin effect is negligible.A single-phase transmission line consisting of two conductors, the radius of each conductor is 0.4 cm, the distance between the conductors is three and half meters and the height above ground is eight 1-The capacitance in uF/km without effect of ground is 2-The capacitance in pF/km with effect of ground is
- (a) A three phase transposed transmission tower comprises of three-bundled conductor and double-circuit configured in vertical position as shown in Figure 2. Each sub-conductor in each circuit and each phase is an ACSR type, size 477,000 cmil and stranding 26/7. Given the GMR of each sub-conductor is 0.8809 cm and diameter is 2.1793 cm, analyze: i. Inductance in mH/km ii. Capacitance in µF/km 0.75m 7.5m b' 4m 4m 45cm Figure 2: A single circuit three-phase transmission line is composed of four ACSR conductors per phase with the horizontal configuration as shown in the figure below. Find the inductance per km length of the transmission line. The radius of each conductor in the bundle is 1.25 cm. m 0.5 0.5 m 0.5 m 4 m 4 mA 60 Hz, three-phase, transposed transmission line, is designed with three bobolink conductors per phase, in horizontal arrangement as shown in the figure below. Distance between consecutive phases is D = 6.2 m and distance among bundle conductors is h =0.5m. Each conductor has a radius of 18 mm and a GMR of 14.39mm. The per phase resistance is 1.677x10-5 2/m. r= 18 mm GMR= 14.39 mm a b h D D The per phase shunt admittance assuming zero conductance in µO/km is: О a., 5.4347 O b. j5.3316 О с /4.2266 O d. j4.0973 O e. 59630.2922 + j10.9770