P01: For the continuous floor system in Fig 1 below, calculate the following: a. be for the beam T-section at section A-A and B-B, b. Design moment for Doubly Reinforced Rectangular beam section (Fig. 4) at section C-C. c. Design moment for Singly reinforced T- beam section (Fig. 2) at section A-A. (See Hint) d. Design moment for Doubly reinforced T-beam section (Fig. 3) at section B-B. (Optional-for further knowledge) Given: a. bw = 1 ft; b. fc=4000 psi and fy = 60 ksi. c. Central floor beam spanning in horizontal direction. d. The floor system has a uniform spacing between beams.

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
Please solve part A and B Subject is reinforced concrete design show all steps
P01: For the continuous floor system in Fig 1 below, calculate the following:
a. be for the beam T-section at section A-A and B-B,
b. Design moment for Doubly Reinforced Rectangular beam section (Fig. 4) at section C-C.
c. Design moment for Singly reinforced T- beam section (Fig. 2) at section A-A. (See Hint)
d. Design moment for Doubly reinforced T- beam section (Fig. 3) at section B-B. (Optional - for
further knowledge)
Given:
a.
bw = 1 ft;
b.
f'c = 4000 psi and fy = 60 ksi.
c. Central floor beam spanning in horizontal direction.
d. The floor system has a uniform spacing between beams.
HINT: For a typical floor system, mid-span sections are subjected to positive bending. Section A-A has a
large compression zone; hence compression steel may not be required for additional moment strength in
this case. Assuming section will include No. 3 or No. 4 stirrups (compression steel in the section is not
shown in the figure which is placed for reinforcement continuity requirements), d= 24 in- 3.5 in= 20.5 in
and d= 24 in - 2.5 in = 21.5 in).
7
Slab thickness=5 in.
24 ft
Figure 1 Continuous Floor System
10 ft
10 ft
Transcribed Image Text:P01: For the continuous floor system in Fig 1 below, calculate the following: a. be for the beam T-section at section A-A and B-B, b. Design moment for Doubly Reinforced Rectangular beam section (Fig. 4) at section C-C. c. Design moment for Singly reinforced T- beam section (Fig. 2) at section A-A. (See Hint) d. Design moment for Doubly reinforced T- beam section (Fig. 3) at section B-B. (Optional - for further knowledge) Given: a. bw = 1 ft; b. f'c = 4000 psi and fy = 60 ksi. c. Central floor beam spanning in horizontal direction. d. The floor system has a uniform spacing between beams. HINT: For a typical floor system, mid-span sections are subjected to positive bending. Section A-A has a large compression zone; hence compression steel may not be required for additional moment strength in this case. Assuming section will include No. 3 or No. 4 stirrups (compression steel in the section is not shown in the figure which is placed for reinforcement continuity requirements), d= 24 in- 3.5 in= 20.5 in and d= 24 in - 2.5 in = 21.5 in). 7 Slab thickness=5 in. 24 ft Figure 1 Continuous Floor System 10 ft 10 ft
3 No. 5 bars
be= 72 in.
6 No. 7 bars
12 in.
I 3.5 in.
Figure 2 T-Beam section at A-A section
13 No. 8 bars
2 No. 8 (No. 25)
b₂ = 72 in.
6 No. 10 (No. 32)
3 No. 7 bars
12 in.
I = 2.5 in.
Is
5. in.
12"
Figure 3 T-Beam Section at B-B section
2/2
-2.5 in.
3 No. 5 bars
24"
Figure 4 Rectangular Beam Section at C-C
24 in.
5 in.
24 in.
Transcribed Image Text:3 No. 5 bars be= 72 in. 6 No. 7 bars 12 in. I 3.5 in. Figure 2 T-Beam section at A-A section 13 No. 8 bars 2 No. 8 (No. 25) b₂ = 72 in. 6 No. 10 (No. 32) 3 No. 7 bars 12 in. I = 2.5 in. Is 5. in. 12" Figure 3 T-Beam Section at B-B section 2/2 -2.5 in. 3 No. 5 bars 24" Figure 4 Rectangular Beam Section at C-C 24 in. 5 in. 24 in.
Expert Solution
steps

Step by step

Solved in 7 steps with 17 images

Blurred answer
Knowledge Booster
Roofing elements and materials
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning