Magnets carrying very large currents
are used to produce the uniform, large-magnitude magnetic fields
that are required for magnetic resonance imaging (MRI). A typical
MRI magnet may be a solenoid that is 2.0 m long and 1.0 m in diameter,
has a self-inductance of 4.4 H, and carries a current of 750 A. A
normal wire carrying that much current would dissipate a great deal
of electrical power as heat, so most MRI magnets are made with coils of superconducting wire cooled by liquid helium at a temperature just
under its boiling point (4.2 K). After a current is established in the wire,
the power supply is disconnected and the magnet leads are shorted together
through a piece of superconductor so that the current flows without
resistance as long as the liquid helium keeps the magnet cold.
Under rare circumstances, a small segment of the magnet’s wire
may lose its superconducting properties and develop resistance. In this
segment, electrical energy is converted to thermal energy, which can
boil off some of the liquid helium. More of the wire then warms up
and loses its superconducting properties, thus dissipating even more
energy as heat. Because the latent heat of vaporization of liquid helium
is quite low (20.9 kJ>kg), once the wire begins to warm up, all of
the liquid helium may boil off rapidly. This event, called a quench, can
damage the magnet. Also, a large volume of helium gas is generated
as the liquid helium boils off, causing an asphyxiation hazard, and the
resulting rapid pressure buildup can lead to an explosion. You can see
how important it is to keep the wire resistance in an MRI magnet at
zero and to have devices that detect a quench and shut down the current
immediately. How many turns does this typical MRI magnet have? (a) 1100;
(b) 3000; (c) 4000; (d) 22,000.
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps
- A square, single-turn wire loop, l = 1.00 cm on a side is placedinside a solenoid that has a circularcross section of radius r =3.00 cm, as shown in the end viewof Figure P20.18. The solenoid is20.0 cm long and wound with 100turns of wire. (a) If the currentin the solenoid is 3.00 A, what isthe flux through the square loop?(b) If the current in the solenoid isreduced to zero in 3.00 s, what is the magnitude of the averageinduced emf in the square loop?arrow_forwardFor a solenoid in vacuum of length / 10 cm with 10* turns per meter calculate the value of the current if the solenoid is placed in an external uniform magnetic field Bext = 35 µT with field lines exactly opposite to the field produced by the solenoid. Take vacuum permeability µo 4r × 10-' H/m. Provide your answer in Sl units.arrow_forwardDLA bullet train iw traveling at 1d traveling at 320.0Km/hr a location Earth's magnetic Pield where the vertical compon ent 4.75 A10 -3丁 of the wheels Is the the aole los0 m aparti what a'cross the axle? induced potential di pperence inarrow_forward
- Let's estimate what kinds of conditions a "military grade" railgun would require. First of all, let's say the muzzle velocity has to be 1000 m/s (actually slow for a railgun). The magnetic field has to be big and so let's choose 10 T. For the gun length, let's choose L = 5 m. Suppose mass of the rod is 0.1 m and its length is 20 cm. The rod maintains contact as it slips. Ignore rolling. L a) Calculate the force that must be acting on the rod. b) To achieve this force, what current must be delivered to the rod?arrow_forwardA 2 meter-long bar is being moved to the right at a constant speed. The bar is sliding on aframe that includes a resistor with R = 3.25 Ω. There is also a uniform 5.75-T magneticfield, directed into the page. At what speed should the bar be moved to produce a currentof 0.800 A in the resistorarrow_forward