Transcribed Image Text:1. Calculate slab dead load intensity in kPa (kilo Pascal = kN/m²) in a main floor condo
building, given the following parameters:
- Allow for 0.3kPa for M&E (i.e. Parkade mechanical and electrical like for example
ducts, light fixtures etc..).
Minimum allowance for partition walls as per ABC2019
175mm concrete slab
0.2kPa for tiling allowance (including tiles, adhesive, and grout)
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- What is the clear wall R-value of a typical 2X6 stud wall assembly? Assume the following: (1)cavity has dense pack cellulose at R 22 (2)there are 1 percent air gaps in the cavity insulation with a nominal R value of 1 for the air gap (3)the framing factor is 22 percent with an R value of 1.25/inch (4) There is 1 inch of continuous XPS (R5/inch) on the exterior (5)Assume the air films, sheathing, facade, and wallboard add an additional 1.5 R value to the wall. Hint: draw this out. Answer:arrow_forwardplease helparrow_forwarddraw One-way slab- 12 mm diam. main bars spaced @ 300 mm o.c. b/w with 10 mm diam. extra top bars spaced at 300 mm o.c.b/w and 10 mm diam.temp. bars spaced @ 300 mm.oc. b/w.arrow_forward
- Describe the key differences between unitized and stick frame curtain wall systems in terms of design, installation, and thermal performance.arrow_forwardIn the plan below there is a conventional L shape stair, the distance between slabs is 2.9m/? find the followings: height ise Assum/hat ar to 16.1 f T'ind the Fr C/ Find the tread width. D/ If the provided area of stair is (2m*3m), check it the area is enough for installation the tair or not? Assume it the stair width is 90 cm. 50-0 OPEN BED ROOM 11-7 X14'-0" LIVING 11-7 X17-10.5" 6-6X4-6" DRAWING 10-0X11-0 25'-0" BATH 8'XS BED ROOM 11-7 X14-0 KITCHEN 11-7 X8-0" PORCH 13-1.5X20-4.5"arrow_forward2. Which type of window tends to be more airtight, double-hung, horizontal sliding, or casement?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Structural Analysis (10th Edition)Civil EngineeringISBN:9780134610672Author:Russell C. HibbelerPublisher:PEARSONPrinciples of Foundation Engineering (MindTap Cou...Civil EngineeringISBN:9781337705028Author:Braja M. Das, Nagaratnam SivakuganPublisher:Cengage Learning
- Fundamentals of Structural AnalysisCivil EngineeringISBN:9780073398006Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel LanningPublisher:McGraw-Hill EducationTraffic and Highway EngineeringCivil EngineeringISBN:9781305156241Author:Garber, Nicholas J.Publisher:Cengage Learning


Structural Analysis (10th Edition)
Civil Engineering
ISBN:9780134610672
Author:Russell C. Hibbeler
Publisher:PEARSON

Principles of Foundation Engineering (MindTap Cou...
Civil Engineering
ISBN:9781337705028
Author:Braja M. Das, Nagaratnam Sivakugan
Publisher:Cengage Learning

Fundamentals of Structural Analysis
Civil Engineering
ISBN:9780073398006
Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:McGraw-Hill Education


Traffic and Highway Engineering
Civil Engineering
ISBN:9781305156241
Author:Garber, Nicholas J.
Publisher:Cengage Learning