In the above figure, a single line model of a three-phase power system is given. Base power 50MVA, base voltage 13.8kV according to its value,
a) Per-unit values of power system circuit elements according to the given base power and base voltage values. calculate.
b) The perunit you calculate by drawing the equivalent impedance circuit for one phase of the power system given in the figure. show on the values.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 4 steps with 12 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- Subject - Design electrical circuits for single phase AC networks Question - Analyse the methods that improve the power factor of a electrical circuit.arrow_forward6. In figure below the rating of reactance and various components are shown. A load of 50MW at p.f. lagging is taking from the 33kv substation which is to be maintained at 30kv. Calculate the terminal voltage of the synchronous machine (Vs) in pu, also represent the line and transformer in series reactance. The system is three phase system V6 11 kV 132 kV 132 kV 33 kV 50 MW Line 0.8 p.f. lagging j1000 50 MVA X 10% 50 MVA X 12% 30 kVarrow_forward2. Given three identical ideal single-phase transformers with each rated at 100KVA and 7kV/3.5kV, they are connected as a three-phase transformer bank. The three-phase transformer has high voltage side connected in delta and the low voltage side is connected in wye. A three-phase 200KVA, wye connected load is connected at the low voltage side of the transformer. Calculate the following: a. Rated line-to-line voltage on each side b. Line current on each side of the transformerarrow_forward
- A short transmission line connects a step-up transformer on the source side with a series impedance of j0.5 ohms (referred to the primary) to a step-down transformer on the load side with a series impedance of 50 ohms (referred to the primary). The turn ratio of the step-up transformer is 1:10 and a no-load primary voltage of 13.2 (line-to-line) kV. The step-down transformer has a turn ratio of 15:1 and it has a Y-connected, balanced load of 0.667 +j 0.111 ohms connected to its secondary side. A capacitor bank of -j0.239 ohms is added parallel to the load. Assuming an ideal transmission line, the load voltage (line-to-neutral) would be: A. 5118 V B. 6.2 kV C. 8865 V D. None of the other choices are correct E. 4225 Varrow_forwardIn power distribution systems, what is sometimes necessary to install to reduce harmonic frequencies and distortion between the three-phase transformers and distribution panels?arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,