Question
In calibration of instrument the 0.055 percent of the calibration span what does it mean. If let say the range of pressure transmitter is 0 - 250 psi. Can you shown me the calibration results using 0.055 percnt calibration span.
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 3 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 5) A pressure gauge which has a linear calibration curve has a radius of scale line as 120 mm and pressure of 0 to 50 Pascal is displayed over an arc of 300°. Determine the sensitivity of the gauge as a ratio of scale length to pressure.arrow_forwardQ. Based on the calibration curves, find out the respective sensitivities of the displacement measurement. 1. Strain (UE) Strain (UE) 0.01 0.00 -0.01 -0.02 -0.03 -0.04 0.0 0.01 0.00 -0.01 -0.02 0 -0.03 -0.0003-0.0009 -0.04 Strain vs. Displacement (Pushing) -0.0369*x + -3.1E-03 R² = 0.984 0.0 0:0063 -0.011 0.1 0.2 0.3 -0.0152 -0.0049 0.1 0.2 -0.0088 -0.0195 0.3 Strain vs. Displacement (Releasing) -0.0378*x + 2.16E-03 R² = 0.991 -0.0231 -0.0265 -0.0124 -0.0163- 0.4 0.5 0.6 0.7 0.8 0.9 1.0 Displacement (in) -0.02 -0.0298 0.4 0.5 0.6 Displacement (in) -0.0325 -0.0235 0.7 -0.0272 -0.0352 0.8 -0.0379 -0.0318 -0.0379 0.9 1.0arrow_forward1.The thickness of a gage block is measured five times using an instrument that has a resolution of 0.001 cm. The following measurements are obtained (in cm): 1.100, 1.110, 1.090, 1.095, and 1.105. The true gauge block thickness is known to be 1.050 cm. Use this information to answer the following questions: a. What errors or sources of measurement error can be identified in the example? (Hint: there are three). Identify each one as a random or systematic uncertainty. b. Estimate the magnitudes of each of these uncertainties. Wherever possible, estimate random uncertainties at a 95% probability/confidence level. c. Based on the uncertainties determined in part b, estimate the overall uncertainty of a measurement obtained by this instrument.arrow_forward
- Consider the voltmeter calibration data in the following table. Plot the data using a suitable scale. Specify the percent maximum hysteresis based on full-scale range. Increasing Input [mV] Decreasing Input [mV] Y Y 0.0 0.1 5.0 5.0 1.0 1.1 4.0 4.2 2.0 2.1 3.0 3.2 3.0 3.0 2.0 2.2 4.0 4.1 1.0 1.2 5.0 5.0 0.0 0.2arrow_forwardYou need to run some vibrations tests and your lab has an accelerometer (2nd order system) that has a natural frequency (resonance) at 3,000 Hz and damping ratio of 0.05. The vibrations you wish to measure are in the range of 100 - 1,200 Hz. a. What are the amplitude error (in %) and phase shift (in degrees) expected at the upper end of the vibration frequency range (1,200 Hz)? b. What is the maximum frequency that you can measure to have no more than 1% error in the amplitude of the reading? c. Is this a suitable choice of accelerometer for this measurement? Why or why not?arrow_forward3. The results of a simple calibration of pressure transducer and its specification are shown in Figure 1 and Table 1. The sensitivity of the pressure sensor is 0.5 V/kPa (given by manufacturer) and the linear curve fit for the upscale calibration is given as y = 0.51x +0.02 . a) Calculate the hysteresis and linearity errors for this calibration. b) Please discuss either the pressure transducer can now be used for the actual measurement or not. Table 1: Pressure tansducer specification Оperation Input range 0- 5 kPa + 15 V 0 - 2.5 V Excitation Output range Performance Linearity error ± 3 % Hysteresis Less than + 15% Sensitivity error + 5% Thermal sensitivity error + 0.02% / °C Temperature range 0 - 50 °C 2.5 upacale mesurement downscale measurement 0.5 0.5 3.5 pressure, kPa Оприt, voltage ((V) Upscale Input, pressure (kPa) Downscale 0.00 0.00 1 0.53 0.48 2 1.05 0.94 3 1.62 1.45 4 2.12 1.95 5 2.50 2.50 Figure 1: Calibration results (plot and tabulated data)arrow_forward
- We wish to measure a characteristic of a machined part whose nominal size is 50 mm at 20 °C. For this, two different instruments are used; an analog micrometer and a digital vernier caliper, both recently calibrated and with the same resolution (0.01 mm). The calibration certificate data of the analog micrometer and the digital vernier are shown in tables 5 and 6 respectively. In both cases the calibration uncertainty does not include the contribution of resolution uncertainty. Additionally, there are drift studies for both instruments and it is established that the drift of the micrometer is ± 0.002 mm while the drift of the vernier is ± 0.02 mm. The same number of measurements were performed with both instruments to avoid repeatability biases under controlled environmental conditions. Table 7 shows the results of the measurements of both instruments. The temperature of the piece was monitored with a digital thermometer whose calibration uncertainty is 0.1 °C, which already includes…arrow_forwardTruncation errors are increased as the round-off errors are decreased.Group of answer choices True False Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 29oC, 29.2oC, 29.3oC, 28.9oC, and 29.1oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is not accurate and not precise The thermometer is faulty. The thermometer is accurate and precise The thermometer is not accurate but precise. Say, you have a thermometer and you are checking the temperature of a body that has a temperature of 36o Using your thermometer five times, it gives you the following measurements: 36oC, 35.6oC, 36oC, 37oC, and 36.2oC. What can we conclude about the accuracy and the precision of the thermometer?Group of answer choices The thermometer is accurate and precise. The thermometer is accurate but not precise. The…arrow_forwarda) Describe static sensitivity and time constant of instrument?b) A thermometer having a time constant of 1 min is initially at 50 oC. It is immersedin a bath maintained at 100 oC at time = 0. Express temperature in oC at time = 1.2minarrow_forward
- Distilled water at 10deg C stands in a glass tube of 9.0 mm diameter at a height of 24.00 mm. What is the true static height in mm if the surface tesnsion is 0.0742 N/m. a.24 mm b.27.4 mm c.20.6 mm d.3.4 mmarrow_forwardAccording to Hooke's Law, we need to be measuring x (the length of the spring) however our CBR is set up to measure y( the height of the bottom of the mass). Create a diagram and explains why we can swap out x variables for y variables when conducting this experiment x yarrow_forwardPlease don't use AI , Attempt only if you understand the problem otherwise leave it to others . Don't waste the timearrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Elements Of ElectromagneticsMechanical EngineeringISBN:9780190698614Author:Sadiku, Matthew N. O.Publisher:Oxford University PressMechanics of Materials (10th Edition)Mechanical EngineeringISBN:9780134319650Author:Russell C. HibbelerPublisher:PEARSONThermodynamics: An Engineering ApproachMechanical EngineeringISBN:9781259822674Author:Yunus A. Cengel Dr., Michael A. BolesPublisher:McGraw-Hill Education
- Control Systems EngineeringMechanical EngineeringISBN:9781118170519Author:Norman S. NisePublisher:WILEYMechanics of Materials (MindTap Course List)Mechanical EngineeringISBN:9781337093347Author:Barry J. Goodno, James M. GerePublisher:Cengage LearningEngineering Mechanics: StaticsMechanical EngineeringISBN:9781118807330Author:James L. Meriam, L. G. Kraige, J. N. BoltonPublisher:WILEY

Elements Of Electromagnetics
Mechanical Engineering
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Oxford University Press

Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:9780134319650
Author:Russell C. Hibbeler
Publisher:PEARSON

Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:9781259822674
Author:Yunus A. Cengel Dr., Michael A. Boles
Publisher:McGraw-Hill Education

Control Systems Engineering
Mechanical Engineering
ISBN:9781118170519
Author:Norman S. Nise
Publisher:WILEY

Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:9781337093347
Author:Barry J. Goodno, James M. Gere
Publisher:Cengage Learning

Engineering Mechanics: Statics
Mechanical Engineering
ISBN:9781118807330
Author:James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:WILEY