horizontal runs of IMC supported by openings through framing members at intervals not exceeding _____ ft and securely fastened within _____ ft of termination points shall be permitted. Select one: A. 1.5,4.5 B. 3,10 C. 2,5 D. 10,3
Q: 5. What is the minimum depth that a USEB90 cable, used as a service conductor, can be buried…
A: USEB 90 cable is used as underground cable to transfer electrical power in houses. These types of…
Q: Type UF cable, buried underground, fed from a 15-ampere, ground-fault circuit interrupter at a…
A: As stated by National Electric Code(NEC),the maximum cover of UF cable or the maximum burial depth…
Q: In the conduit layout shown in picture attached, determine how many wires are contained in each…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: Access to and egress from refer to the actual working space requirements about electrical equipment,…
A: Access to and egress from referring to the actual working space requirements about electrical…
Q: 2. Identify and explain the safety procedures and precautions when working with tools and…
A: Electrical cables are used for sending signals and also for long distance communication. There are…
Q: A service disconnection means must be installed adjacent to, within sight of, and no more than…
A: According to question we have to discuss about A service disconnection means must be installed…
Q: Q.4. Mention the specifications of EIA/TIA recognized cables and its standard number for each type…
A: With industry input, the TIA/EIA cable standards have been developed by the Telecommunications…
Q: The minimum depth for a 120-volt, 20-ampere, GFCI protected circuit to an outdoor receptacle run…
A: The depth for the underground installation of the cable is described in the Electric code Section…
Q: 9. How is equipment containing ungrounded electrical systems required to be marked? A. With green…
A: An ungrounded system is a system that is not grounded intentionally. The neutral wire of an…
Q: Define cable rating in a built environment
A: Cable selection and application : It is essential to know cable construction, characteristics,…
Q: Question 5 If a building or structure is supplied by a feeder from an outdoor separately derived…
A: Given statement, If a building or structure is supplied by a feeder from an outdoor separately…
Q: Identify and explain the safety procedures and precautions when working with tools and equipment's…
A: Electrical cables are used for transferring the signals and are also used for long distance…
Q: The frames of ranges, wall-mounted ovens, counter-mounted cooking units, and clothes dryers under…
A: Materials that allow current to flow through them are called conductors. The materials that do not…
Q: draw a block diagram of the jumpers connected to the front panel of a computer system unit
A:
Q: 3. All exposed noncurrent-carrying metal parts of an information technology system shall be to the…
A: All the exposed noncurrent carrying metal parts of an information technology system shall be bonded…
Q: 12. What is the conduit and wire equivalent to a 400A bus duct with both copper and aluminum?…
A: The National Electrical Code (NEC) is a collection of rules for the secure electrical wiring wiring…
Q: draw a schematic diagram of the jumpers connected to the front panel of a computer system unit.
A: Jumpers allow the computer to shut down the electrical circuit, allowing electricity to flow to…
Q: List the methods by which an equipment grounding conductor is connected to a device box
A:
Q: 10.a. Which of the following is a condition of the exception that allows the grounded conductor of…
A: According to guidelines we need to solve only first question. According to the question we have to…
Q: Basically, ______receptacles are required to be installed if an equipment grounding conductor is…
A: Article 406 of NEC covers the installation of receptacles of both grounded type and non-grounded…
Q: It is not possible to locate electrical equipment in less-hazardous areas, or in nonhazardous…
A: Hazardous sites are defined in electrical and safety engineering as places where there is a risk of…
Q: 6. Which of the following is a condition that a liquidtight flexible metal conduit must meet in…
A: Given :few mcqs on flexible metal conduit
Q: If a separate, wire-type equipment grounding conductor (EGC) is used for any reason, the EGC of a…
A: Equipment grounding Equipment grounding includes exposed conductive parts which can get energized.…
Q: L1. Boxes are classified by type, construction, and A. installation location. B. luminaire support…
A: 1) Boxes are referred as a electrical boxes are of plastic or metallic, Boxes are used in light…
Q: Where a building or structure is suplkied by more than one service, or a combination of branch…
A: By National Electrical Code (NEC), Article 225, there were a simple and fair way to install a…
Q: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
A: single-pole portable cable connectors for a portable switchboard on stage, where used, shall be…
Q: In selecting the service entrance size, what should be considered?
A: The power system has to transmit power from the generation side to the load side. For this purpose,…
Q: 14. Severe burns, lung damage, eye damage, and hearing loss are all effects of what event? 8 am…
A: In this question we need to choose a correct option
Q: Connections from headers to cabinets and other enclosures, in cellular concrete floor raceways,…
A: To explain the means of connection made from header to cabinets and other enclosures, in cellular…
Q: In both exposed and concealed locations, where a cable or raceway-type wiring method is installed…
A:
Q: procedures
A: Explanation: The safety procedures and precautions to be taken when working with tools and…
Q: Assuming that an outlet box for the entry ceiling has a fixture stud but has external cable clamps,…
A: Evaluating the number of conductor required for outlet box: The number of conductors present there…
Q: 21.Which of the following wiring methods may be used inside the duct used for vapor removal and…
A: 21. As per the NEC guidelines, no wiring system should be installed in any duct used for vapor…
Q: Plans require the installation of surface-mounted fluorescent luminaires on the ceiling of a…
A: As per the NEC surface-mounted fluorescent luminaires that are to be installed on the low-density…
Q: Write a project management report that includes surveying, excavation, groundwater extraction,…
A: The cutoff is essentially a wall built into the foundation with impermeable material to limit the…
Q: A ____shall be used to connect the equipment grounding conductors, the service equipment enclosures,…
A: Given, 3 multiple choice questions related to national electrical code.(NEC). Please find the below…
Q: 19. When you're connecting a bonding jumper to the structural steel of a building, the jumper must…
A: NEC: NEC stands for National Electric Code. It is a regulatory body that set standard for safety…
Q: In the conduit diagram shown in attached picture, determine how many wires are in each conduit…
A: The circuit is shown below: Between the three-phase line and the disconnect switch. The switch is…
Q: Flexible metal conduit (FMC) shall be securely fastened in place by an approved means within ____…
A: FMC shall be securely fastened in place by an approved means within 12 in of each box ,cabinet,…
Q: Briefly discuss the loaded and non-loaded telephone cables
A: Loading is the process to increase inductance of line by adding lumped inductors atpredefined…
Q: Identify and describe the step-by-step process used to install cable in the NCT Colledge buildings
A: according to question, Identify and describe the step-by-step process used to install cable in the…
Q: S. The general receptacle spacing requirements for all dwelling units are located in Section of the…
A: We are authorized to answer one question at a time, since you have not mentioned which question you…
Q: The wording that I am running into with questions such as "The number of conductors required to be…
A: The number of conductors required to be installed between three-way and four-way switches is white…
Q: The copper line with a total length of 20 meters operates in the 220 volt city network. If three…
A:
Q: Draw the block diagram of staircase ramp type digita oitmeter and explain the same.
A: consider the given question;
Trending now
This is a popular solution!
Step by step
Solved in 2 steps
- 15. What does a grounding symbol on a construction drawing convey?A. A single ground rodB. A grounding electrode systemC. A ground-fault current pathD. An equipment grounding conductorReceptacle and cord terminals should be marked as follows;A. “X” and “O” ungrounded, “W” grounded and “G” equipment groundingB. “Y” and “X” ungrounded, “N” grounded and “GR” equipment groundingC. “X” and “O” ungrounded, “W” grounded and “E” equipment groundingD. “X” and “Y” ungrounded, “W” grounded and “G” equipment grounding14. How many separate equipment grounding paths are required for branch circuits serving patient care spaces? A. One B. Two C. Four D. Three
- Type UF cable, buried underground, fed from a 15-ampere, ground-fault circuit interrupter at a one-family dwelling must have a minimum cover of ______ in. Select one: A. 24 B. 18 C. 6 D. 1211. Which of the following statements about the use of structural steel as an equipment grounding conductor (EGC) in an AC system is correct? A. Structural steel can be used as an EGC when it's bonded at both ends.B. Structural steel isn't allowed for use as an EGC.C. Structural steel must have an EGC bonding jumper every three feet of structure. D. Structural steel can be used as an EGC bonding jumper between panelboards. 12. Which of the following statements about equipment grounding conductors is true? A. They increase voltages above ground potential on conductors and equipment enclosures during normal operation. B. Unacceptable equipment grounding conductors include conduit, tubing, and cable armor. C. They must be capable of withstanding the higher level of ground-fault current to perform their safety function. D. When they're far from their associated circuit conductors, impedance values are kept as low as possible during ground-fault conditions. 13. Imagine that…3. Which of the following statements about the use of structural steel as an equipment grounding conductor(EGC) in an AC system is correct?A. Structural steel isn't allowed for use as an EGC.B. Structural steel can be used as an EGC bonding jumper between panelboards.C. Structural steel must have an EGC bonding jumper every three feet of structure.D. Structural steel can be used as an EGC when it's bonded at both ends.
- 7.B. The size of a grounding electrode conductor for a service or separately derived system is generally basedon the size of the largestA. ungrounded supply conductor.B. equipment grounding conductor.C. grounded electrode.D. bonding jumper.7.C. Which of the following statements about bonding is true?A. The joint or termination must offer opposition in the circuit for effective electrical connections.B. Effective bonding keeps impedance high if a fault should occur.C. The entire electrical safety circuit is only as good as its strongest bonded link.D. Bonding connections must endure high levels of fault current until overcurrent protective devices can operate.6. Which of the following statements about bonding is true?A. The strike terminals of a lightning protection system must be bonded to the building or structure grounding electrode system.B. Bonding requirements on the supply side of the service disconnect are less restrictive.C. Wire-type supply-side bonding jumpers are usually short in length and installed from the service-entrance conductor to asingle raceway.D. Metal water piping systems have one set of rules in the National Electrical Code.Estimate the length of conduit to perform the next bends. EMT will be bend using a hand bender. Provide your answer in inches (just the number) using up to 2 decimals. The picture shows two panels connected by a back-to-back 23.5" stubs EMT 3/4" 6.25 ft P
- 1. A 30-ampere, 120-volt, UF cable circuit is buried from a dwelling unit to a detached outbuilding. The minimum depth of this cable is inches. A. 6 inches C. 24 inches Ans. B. D. 12 inches 18 inchesL1. Boxes are classified by type, construction, andA. installation location.B. luminaire support capability.C. number of knockouts.D. power rating L2. Which of the following devices must be placed at each end of an armored cable to prevent damage tothe conductors?A. An insulating sliderB. An insertion couplingC. An antishort bushingD. A metal loop fitting L3. Which of the following is the maximum cross-sectional conductor fill area for underfloor raceways?A. 50%B. 60%C. 40%D. 30%A Type NM cable carries a branch circuit to the outside of a building, where it terminates in a metal weatherproof junction box. From this box, a short length of EMT is installed upward to another metal weatherproof junction box on which is attached a cluster of outdoor floodlights. The first box is located approximately 24 in. (600 mm) above the ground. To Meet Code, do the metal boxes and metal raceway have to be grounded? Yes _______________ No _______________ NEC _______________.