Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer equivalent circuit are: RI = 0.5 2, R2= 0.005 2, X1 = 0.5 2, X2=0.005 . The excitation impedance parameters referred to LVS are: Rc 500 n and XM = 50 2. The transformer is fully-loaded at 0.8 PF lagging and the load voltage is maintained at 200 V. Using the approximate L-equivalent circuit, the input power factor of the system: 81.7 % lagging zenor zeno 75.08 % lagging 80 % lagging 78.16 % lagging

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter3: Power Transformers
Section: Chapter Questions
Problem 3.10P: A single-phase step-down transformer is rated 13MVA,66kV/11.5kV. With the 11.5 kV winding...
icon
Related questions
icon
Concept explainers
Question
Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the
transformer equivalent circuit are: RI = 0.5 2, R2 0.005 2, X1 = 0.5 ,X2= 0.005 2. The
excitation impedance parameters referred to LVS are: Rc = 500 n and XM = 50 2. The
transformer is fully-loaded at 0.8 PF lagging and the load voltage is maintained at 200 V.
Using the approximate L-equivalent circuit, the input power factor of the system:
81.7 % lagging
zenor
75.08 % lagging
80 % lagging
78.16 % lagging
Transcribed Image Text:Given a 20 kVA, 50 Hz, 2000/200 V single-phase transformer. The parameters of the transformer equivalent circuit are: RI = 0.5 2, R2 0.005 2, X1 = 0.5 ,X2= 0.005 2. The excitation impedance parameters referred to LVS are: Rc = 500 n and XM = 50 2. The transformer is fully-loaded at 0.8 PF lagging and the load voltage is maintained at 200 V. Using the approximate L-equivalent circuit, the input power factor of the system: 81.7 % lagging zenor 75.08 % lagging 80 % lagging 78.16 % lagging
Expert Solution
steps

Step by step

Solved in 3 steps with 2 images

Blurred answer
Knowledge Booster
Types of Distribution in Power System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning