Example: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results: Open-circuit test (HV side open): 100 V, 6 A, 400 W Short-circuit test (LV side shorted): 50 V, 100 A, 1800 W Draw the equivalent circuit of the transformer referred to the high- voltage side. Label impedances numerically in ohms and in per unit. Determine the voltage regulation at rated secondary current with 0.6 power factor lagging. Assume the primary is supplied with rated voltage Determine the efficiency of the transformer when the secondary current is 75% of its rated value and the power factor at the load is 0.8 lagging with a secondary voltage of 98 V across the load

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
Example: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer
has the following test results:
Open-circuit test (HV side open): 100 V, 6 A, 400 W
Short-circuit test (LV side shorted): 50 V, 100 A, 1800 W
Draw the equivalent circuit of the transformer referred to the high-
voltage side. Label impedances numerically in ohms and in per
unit.
Determine the voltage regulation at rated secondary current with
0.6 power factor lagging. Assume the pri
rated voltage
ary is supplied with
Determine the efficiency of the transformer when the secondary
current is 75% of its rated value and the power factor at the load is
0.8 lagging with a secondary voltage of 98 V across the load
Transcribed Image Text:Example: A single-phase, 100-kVA, 1000:100-V, 60-Hz transformer has the following test results: Open-circuit test (HV side open): 100 V, 6 A, 400 W Short-circuit test (LV side shorted): 50 V, 100 A, 1800 W Draw the equivalent circuit of the transformer referred to the high- voltage side. Label impedances numerically in ohms and in per unit. Determine the voltage regulation at rated secondary current with 0.6 power factor lagging. Assume the pri rated voltage ary is supplied with Determine the efficiency of the transformer when the secondary current is 75% of its rated value and the power factor at the load is 0.8 lagging with a secondary voltage of 98 V across the load
Expert Solution
steps

Step by step

Solved in 2 steps with 1 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,