Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN: 9780133923605
Author: Robert L. Boylestad
Publisher: PEARSON
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Determine the main dimensions and Turns per phase (T ph )of 1 3000 kVA 6.6 kV, 50 Hz, 187 r.p.m., 3-phase, star connected alternator. Assume average flux density 0.58 Wb/m², ac = 35000. Assume pole arc/pole pitch = 0.7.
Expert Solution
arrow_forward
Step 1
Step by stepSolved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- A 3-phase,50Hz, 4-pole, Y-connected alternator has 6 slots per pole per phase. The armature has double layers winding. The windings are arranged as 5 conductors per layer. The coil pitch is 5/6th of the full pitch and the flux per pole is o.o5Wb. Determine the voltag per phasearrow_forwardA 4 pole, 3 phase, star-connected alternator has 24 slots with 12 conductors per slot and the flux per pole is 0.1 Wb. Calculate the line emf generated when the alternator is driven at 1500 rpm. All phase conductors are connected in series. Assume sinusoidal emf. (Ans = 1785 V)arrow_forwardCalculate the speed and open-circuit line and phase voltages of a 4-pole, 3phase, 50 Hz star- connected alternator with 36 slots and 30 conductors per slot. The flux per pole is 0.05 Wb sinusoidally distributed.arrow_forward
- In a Three-phase alternator, a given field current produces an armature current of 250 A on short-circuit and a generated e.m.f. of 1500 V on open-circuit. Calculate the terminal p.d. when a load of 250 A at 6.6 kV and 0.8 p.f. lagging is switched off. Calculate also the regulation of the alternator at the given load. Subject: Electrical engineeringarrow_forward5arrow_forwardA four pole, 1200 rpm DC lap wound generator has 1520 conductors. If the flux per poles is 0.01 Wb. Find the generator emf ?arrow_forward
- A three-phase star connected alternator has 6 poles and must give an f.e.m. 380 V at 50 Hz. The stator has 3 slots per pole and phase and 4 conductors per groove. Calculate: a) r.p.m. to which the rotor must rotate; b) the maximum flow per pole if it has a sinusoidal distribution. NOTE: The coils are diametrical pitch.arrow_forwardUsing logic gates, draw a logic circuit for adding and subtracting numbers (numbers converted to formula 01) where the input is by switches and the output is connected to Segment ships to display the result of the addition and subtraction process, the circuit is 4 bits.arrow_forward18. The speed at which a 6-pole alternator should be driven to generate 50 cycles per second is. (i) 1500 r.p.m. (ii) 1000 r.p.m. (iii) 500 r.p.m. (iv) none of the abovearrow_forward
- Alamouti scheme is an example of A. Space time coding B. MIMO C. None of thesearrow_forwardThere are 144 slots in a 3-phase, 16-pole, 50 Hz., star connected alternator. There are 4 conductors in each slot and all the conductors in a phase are connected in series. Coil span is 1500 electrical and the flux per pole is 0.05 Weber sinusoidallly distributed. Calculate the emf induced per phase.arrow_forwardA 6 pole, delta connected three-phase alternator having 144 slots is wound using double layer lap coils having 7 turns per coil. The coil has 16 / 24 pitch. The flux per pole is 7380000 maxuells. If the alternator is driven at a speed of 700 rpm, determine the total line-to-line generated voltage.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,