cable The 1st Run of the Power Line Consumption 1 Generation 1 The 2nd Run cable Consumption 2 Generation 2 cable The 3rd Run Consumption 3 Generation 3 consum- genera- consum- type length cos COS Q type length COS Q ption 1 tion 1 ption 2 genera- tion 2 consum- cos type length COS Q ption 3 genera -tion 3 COS Q Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] cap 95/16 8000 2250 0.95 1 95/16 4000 1750 0.95 1 95/16 3000 2400 0.95 1000 0.95 The 4th Run cable Consumption 4 Generation 4 The 5th Run cable Consumption 3 Generation 3 consum- genera consum- genera type length COS Q COS Q type length ༔ COS Q cos Q ption 4 -tion 4 ption 5 -tion 5 Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] сар 70/11 3000 2400 0.98 1000 0.95 70/11 3000 2300 0.95 1000 0.98
cable The 1st Run of the Power Line Consumption 1 Generation 1 The 2nd Run cable Consumption 2 Generation 2 cable The 3rd Run Consumption 3 Generation 3 consum- genera- consum- type length cos COS Q type length COS Q ption 1 tion 1 ption 2 genera- tion 2 consum- cos type length COS Q ption 3 genera -tion 3 COS Q Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] cap 95/16 8000 2250 0.95 1 95/16 4000 1750 0.95 1 95/16 3000 2400 0.95 1000 0.95 The 4th Run cable Consumption 4 Generation 4 The 5th Run cable Consumption 3 Generation 3 consum- genera consum- genera type length COS Q COS Q type length ༔ COS Q cos Q ption 4 -tion 4 ption 5 -tion 5 Al/Fe [m] [kW] ind [kW] cap Al/Fe [m] [kW] ind [kW] сар 70/11 3000 2400 0.98 1000 0.95 70/11 3000 2300 0.95 1000 0.98
Electricity for Refrigeration, Heating, and Air Conditioning (MindTap Course List)
10th Edition
ISBN:9781337399128
Author:Russell E. Smith
Publisher:Russell E. Smith
Chapter7: Alternating Current, Power Distribution, And Voltage Systems
Section: Chapter Questions
Problem 12RQ
Related questions
Question
Perform a detailed voltage analysis in the given medium-voltage 6-node radial power system example. Reflect on voltage drops, power losses and line efficiency for your given consumption, for consumption that is 25% higher and consumption that is 25% lower.
Then repeat all 3 analyses if the consumption at node 5 is with power factor of 1.
Analyse and discuss the sensitivity of voltage drop [in % of amplitude] and with respect to the current level and the power factor.
Identify the maximal generating power (MW only) that your network can accept in a single node without voltage in any node exceeding 1.05 p.u.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by step
Solved in 2 steps
Recommended textbooks for you
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning