b) The general function of the circuit breaker (CB) is to close and open the circuit to be able to remove faults and connect/disconnect objects and parts of electricity network. Describe the failures of circuit breaker and purpose of circuit breaker testing at the substations.

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
icon
Concept explainers
Question
b) The general function of the circuit breaker (CB) is to close and open the circuit to
be able to remove faults and connect/disconnect objects and parts of electricity
network. Describe the failures of circuit breaker and purpose of circuit breaker
testing at the substations.
c) Figure 3 (c) shows the overview of the high voltage components in the power
network. Based on the power network, the 33/11kV power transformer tripped due
to high winding temperature above 120 °C. The maintenance personnel are planning
to carry out the electrical testing on tripped transformer before proceeding with
further remedial action. Using your own words, describe THREE (3) types of
electrical testing need to be carried out with technical explanation to verify the
condition of tripped transfomer in the power network.
Disconnecto
Protective
elays
HV cit
Breer
Crert
aome
Caret
banslormers
HV oirtut
breaar
Aulary
Votage
vansformer
Daconnector
power
Figure 3 (c)
卡月
Transcribed Image Text:b) The general function of the circuit breaker (CB) is to close and open the circuit to be able to remove faults and connect/disconnect objects and parts of electricity network. Describe the failures of circuit breaker and purpose of circuit breaker testing at the substations. c) Figure 3 (c) shows the overview of the high voltage components in the power network. Based on the power network, the 33/11kV power transformer tripped due to high winding temperature above 120 °C. The maintenance personnel are planning to carry out the electrical testing on tripped transformer before proceeding with further remedial action. Using your own words, describe THREE (3) types of electrical testing need to be carried out with technical explanation to verify the condition of tripped transfomer in the power network. Disconnecto Protective elays HV cit Breer Crert aome Caret banslormers HV oirtut breaar Aulary Votage vansformer Daconnector power Figure 3 (c) 卡月
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Protection System in Power Plant
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,