(b) Design the Beam B-B for the maximum sagging section only. Your design should consider the ultimate limit state and serviceability limit state, and the following points: • Concrete strength of fck should be used. Reinforcement grade of fy should be used. Preliminary section should be selected as rectangular width (b) x depth (h) (mm). A sketch of the final cross-section details should be shown ● ● ●

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question

answer untill step 4 only 

Please I need clear Answer with full details. DO NOT COPPY THE ANSWER

IF YOU DO NOT WANT TO ANSWER MY QUESTION, DO NOT REJECTED IT. SOMEONE ELSE WILL SOLVE IT

  If you are copy from other websites solution I will give you down vote 

(b) Design the Beam B-B for the maximum sagging section only. Your design should consider the ultimate
limit state and serviceability limit state, and the following points:
• Concrete strength of fek Should be used.
Reinforcement grade of fy should be used.
Preliminary section should be selected as rectangular width (b) x depth (h) (mm).
• A sketch of the final cross-section details should be shown
Steps:
Design of concrete beam:
Structural Data
Beam Strngth Column Stergth
Colum Strength
1. Design loads
2. Design moments and shear
222 33
122 3.55 455 25.5
472 305
472
3. Concrete cover
4. Flexural reinforcement and details (inc. drawing)
5. Check for ductility
6. Shear reinforcement
7. Span/depth calculation
8. Serviceability check
Transcribed Image Text:(b) Design the Beam B-B for the maximum sagging section only. Your design should consider the ultimate limit state and serviceability limit state, and the following points: • Concrete strength of fek Should be used. Reinforcement grade of fy should be used. Preliminary section should be selected as rectangular width (b) x depth (h) (mm). • A sketch of the final cross-section details should be shown Steps: Design of concrete beam: Structural Data Beam Strngth Column Stergth Colum Strength 1. Design loads 2. Design moments and shear 222 33 122 3.55 455 25.5 472 305 472 3. Concrete cover 4. Flexural reinforcement and details (inc. drawing) 5. Check for ductility 6. Shear reinforcement 7. Span/depth calculation 8. Serviceability check
Figure 1 shows the plan view of an exhibition hall with dimensions L, x L2. The structure is to be
constructed in a coastal region which will be exposed to mostly mild environmental conditions, and should
provide a 1.5 hour fire resistance. It is known that the underlying foundation soil contains sulfate and
other organic compounds.
The layout of the structure consists of portal frames which are spaced evenly along the L; direction. The
frames are to support a slab of thickness (t) that will cover the full area of the hall plan. The dead and live
loads applied on the slab are G and Q (kPa), respectively.
Figure 2 shows the elevation view of Frames B and D. All columns have a floor-to-floor height (H) and are
monolithically connected to the beams. Columns are also fixed to the foundation at the base, and it may
be assumed that all frames are fully braced.
в с D E F
А в с D E FG
Figure 1: Plan of exhibition hall.
D
D1
D2
D3
L1
L1/2
L1/2
Figure 2: Elevation of Frames B and D.
B.
Transcribed Image Text:Figure 1 shows the plan view of an exhibition hall with dimensions L, x L2. The structure is to be constructed in a coastal region which will be exposed to mostly mild environmental conditions, and should provide a 1.5 hour fire resistance. It is known that the underlying foundation soil contains sulfate and other organic compounds. The layout of the structure consists of portal frames which are spaced evenly along the L; direction. The frames are to support a slab of thickness (t) that will cover the full area of the hall plan. The dead and live loads applied on the slab are G and Q (kPa), respectively. Figure 2 shows the elevation view of Frames B and D. All columns have a floor-to-floor height (H) and are monolithically connected to the beams. Columns are also fixed to the foundation at the base, and it may be assumed that all frames are fully braced. в с D E F А в с D E FG Figure 1: Plan of exhibition hall. D D1 D2 D3 L1 L1/2 L1/2 Figure 2: Elevation of Frames B and D. B.
Expert Solution
steps

Step by step

Solved in 7 steps with 20 images

Blurred answer
Knowledge Booster
Connections
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning