ANGLE 30° 60° 90° 90/38cm 90/38cm 90/76cm 90/114cm 90/152cm 90/185cm 90/215 SHADING % 10% 50% 100% 0% 10% 20% 30% 50% 80% 100% IRRADIATION 45.79| 34.70 52.79 86.96 85.56 107.1 107.3 46.02 65.26 99.76 VOLTAGE 19.21 19.53 19.19 19.52 19.14 19.11 19.27 19.42 19.53 19.65 0.015 0.017 0.288 | 0.346 AMPERE 0.016 0.021 0.022 0.022 0.022 0.022 0.024 0.024 POWER 0.323 0.411 0.432 0.426 0.426 0.444 0.484 0.471 a. In table. At what percentage of shade that current, voltage and power reach the minimum output? Explain your answer? b. In table. Record the result of this shading effect on the output of a solar module? c. In your own conclusion, in table. What is the effect of shading to the efficiency of the performance of the PV cell with regards to Voltage, Current and Power? Explain

Introductory Circuit Analysis (13th Edition)
13th Edition
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:Robert L. Boylestad
Chapter1: Introduction
Section: Chapter Questions
Problem 1P: Visit your local library (at school or home) and describe the extent to which it provides literature...
icon
Related questions
Question
ANGLE
30°
60°
90°
90/38cm
90/38cm
90/76cm
90/114cm
90/152cm
90/185cm
90°/215
SHADING %
10%
50%
100%
0%
10%
20%
30%
50%
80%
100%
IRRADIATION
45.79 34.70
52.79
86.96
85.56
107.1
107.3
46.02
65.26
99.76
VOLTAGE
19.21
19.53
19.19
19.52
19.14
19.11
19.27
19.42
19.53
19.65
AMPERE
0.015
0.017
0.016
0.021
0.022
0.022
0.022
0.022
0.024
0.024
POWER
0.288 0.346
0.323
0.411
0.432
0.426
0.426
0.444
0.484
0.471
In table. At what percentage of shade that current, voltage and power reach the minimum
a.
output? Explain your answer?
b. In table. Record the result of this shading effect on the output of a solar module?
c. In your own conclusion, in table. What is the effect of shading to the efficiency of the performance
of the PV cell with regards to Voltage, Current and Power? Explain
Transcribed Image Text:ANGLE 30° 60° 90° 90/38cm 90/38cm 90/76cm 90/114cm 90/152cm 90/185cm 90°/215 SHADING % 10% 50% 100% 0% 10% 20% 30% 50% 80% 100% IRRADIATION 45.79 34.70 52.79 86.96 85.56 107.1 107.3 46.02 65.26 99.76 VOLTAGE 19.21 19.53 19.19 19.52 19.14 19.11 19.27 19.42 19.53 19.65 AMPERE 0.015 0.017 0.016 0.021 0.022 0.022 0.022 0.022 0.024 0.024 POWER 0.288 0.346 0.323 0.411 0.432 0.426 0.426 0.444 0.484 0.471 In table. At what percentage of shade that current, voltage and power reach the minimum a. output? Explain your answer? b. In table. Record the result of this shading effect on the output of a solar module? c. In your own conclusion, in table. What is the effect of shading to the efficiency of the performance of the PV cell with regards to Voltage, Current and Power? Explain
Expert Solution
steps

Step by step

Solved in 2 steps

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Introductory Circuit Analysis (13th Edition)
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:
9780133923605
Author:
Robert L. Boylestad
Publisher:
PEARSON
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Programmable Logic Controllers
Programmable Logic Controllers
Electrical Engineering
ISBN:
9780073373843
Author:
Frank D. Petruzella
Publisher:
McGraw-Hill Education
Fundamentals of Electric Circuits
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:
9780078028229
Author:
Charles K Alexander, Matthew Sadiku
Publisher:
McGraw-Hill Education
Electric Circuits. (11th Edition)
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:
9780134746968
Author:
James W. Nilsson, Susan Riedel
Publisher:
PEARSON
Engineering Electromagnetics
Engineering Electromagnetics
Electrical Engineering
ISBN:
9780078028151
Author:
Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:
Mcgraw-hill Education,