Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN: 9781305632134
Author: J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher: Cengage Learning
expand_more
expand_more
format_list_bulleted
Concept explainers
Question
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 2 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of an unloaded synchronous machine decreases from a high initial value to a lower steady-state value, going periods through the stages of __________ and ________ periods.arrow_forwardQ20. The section bus-bars A and B as shown in Figure B5 are linked by a bus-bar reactors each rated at 5000 kVA with 10% reactance. On bus-bar A, there are two generators each of 10,000 kVA with 10% reactance and on B two generators each of 8000 kVA with 12 % reactance. Find the Current and MVA that fed into a dead short circuit between all phases on B with bus-bar reactor in the circuit. Page 4 of 5 جامعة التقنية والعلومر التطبيقية بإبراء University of Technology and Applied Sciences - Ibra Student ID: Section: Student Name: 8,000 kVA 12% 10,000 kVA 10,000 kVA 10% 8,000 kVA 12% 10% 2 3 5,000 kVA 10% lell 8,000 kVA 10% Figure B5 "End of Question Paper"arrow_forwardThe bus bars of a power station are in two sections A and Bseparated by a reactor. Connected in section A are two 12MVA generators of 15% reactance each and to B, 8 MVAgenerator of reactance 10%. The reactor is rated 8 MVA and15% reactance. Two feeders are connected to bus bar Athrough transformers, each rated at 4 MVA and 5% reactance.Determine the maximum short circuit MVA with which circuitbreakers on the outgoing side of the transformers have todeal.arrow_forward
- Q2. The single-line diagram of a simple three-bus power system is shown in Figure-2. Each generator is represented by an emf behind the sub-transient reactance. All impedances are expressed in per unit on a common MVA base. All resistances and shunt capacitances are neglected. The generators are operating on no load at their rated voltage with their emfs in phase. A three-phase fault occurs at bus 3 through a fault impedance of Zf = j0.19 per unit. (i) Using Th'evenin's theorem, obtain the impedance to the point of fault and the fault current in (ii) Determine the bus voltages per unit. ) j0.05 j0.075 j0.75 2 j0.30 j0.45 Figure-2: Single line diagram of the power system network for Q2 3arrow_forwardWhat are the hazards of phase failure and phase reversal?arrow_forwardId is : 510221arrow_forward
- A 60 Hz, 33 kV, 3-phase alternator with earthed neutral has a reactance of 7 ohms per phase and is connected to a bus-bar through a circuit breaker. The distributed capacitance upto circuit breaker between phase and neutral in 0.03 uF. Determine (i) peak re-striking voltage across the contacts of the breaker (ii) frequency of oscillationsarrow_forwardProblem #2: A transformer is fed from a generator via a 5-cycle breaker. Generator reactance are: X"=18%, X'=25%, Xe=120%. A three-phase fault occurs at the load side of the breaker when the transformer was unloaded. Find: A)The sustained short circuit current in the breaker. B) Initial symmetrical rms current in the breaker. C) Maximum dc short circuit component in the breaker.arrow_forwardDescribe the effects of harmonics on power distribution system.arrow_forward
- Full calculation with any assumption needed. All sub questions please as it is all related.arrow_forwardQ5: A generator is connected through a transformer to a synchronous motor. Reduced to the same base, the per unit subtransient reactances of the generator and motor are 0.15 and 0.35, respectively, and the leakage reactance of the transformer is 0.1 per uint. A three-phase fault occurs at the terminals of the motor when the terminal voltage of the generator is 0.9 per uint and the output current of the generator is 1 per unit at 0.8 power factor leading. Find the subtransient current in per unit in the fault, in the generator, and in the motor. Use the terminal voltage of the generator as the reference phasor and obtain the solution (a) by using the internal voltages of the machines and (b) by using Thevenin's theorem.arrow_forward5. Two 75 MVA 3-phase alternator are connected in parallel. The speed load characteristic of the first generator is 2% from no-load to full load while that of the second alternator is 3% from no-load to full load. The machines are fully loaded when the load is 150 MVA. If the load is reduced to 80 MVA. Calculate the load carried by each machines?arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning