Transcribed Image Text:An interconnection reactor system is shown in
fig.. The base values for the given percent
reactances are the ratings of the individual
pieces of equipment. A three phase short
circuit occurs at point F. Determine the fault
current and fault KVA if the bus-bar line to line
voltage is 11 kV.
10MVA
10%.
G₁
20MVA
15%
G₂
X₁
-0000
10MVA
5%
20MVA
15%
G3
-0000
8MVA
4%
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 2 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- The amplitude of the sinusoidal symmetrical ac component of the three-phase short-circuit current of an unloaded synchronous machine decreases from a high initial value to a lower steady-state value, going periods through the stages of __________ and ________ periods.arrow_forwardQ20. The section bus-bars A and B as shown in Figure B5 are linked by a bus-bar reactors each rated at 5000 kVA with 10% reactance. On bus-bar A, there are two generators each of 10,000 kVA with 10% reactance and on B two generators each of 8000 kVA with 12 % reactance. Find the Current and MVA that fed into a dead short circuit between all phases on B with bus-bar reactor in the circuit. Page 4 of 5 جامعة التقنية والعلومر التطبيقية بإبراء University of Technology and Applied Sciences - Ibra Student ID: Section: Student Name: 8,000 kVA 12% 10,000 kVA 10,000 kVA 10% 8,000 kVA 12% 10% 2 3 5,000 kVA 10% lell 8,000 kVA 10% Figure B5 "End of Question Paper"arrow_forwardThe bus bars of a power station are in two sections A and Bseparated by a reactor. Connected in section A are two 12MVA generators of 15% reactance each and to B, 8 MVAgenerator of reactance 10%. The reactor is rated 8 MVA and15% reactance. Two feeders are connected to bus bar Athrough transformers, each rated at 4 MVA and 5% reactance.Determine the maximum short circuit MVA with which circuitbreakers on the outgoing side of the transformers have todeal.arrow_forward
- Supposed a 5000 kva, 13.8 volt, 60 hz, 3-phase capacitor bank with grounded neutral is being switched through a circuit breaker, through a source of 1 millihenry. what is the peak current at restrike voltage?arrow_forwardWhat are the hazards of phase failure and phase reversal?arrow_forwardId is : 510221arrow_forward
- A 60 Hz, 33 kV, 3-phase alternator with earthed neutral has a reactance of 7 ohms per phase and is connected to a bus-bar through a circuit breaker. The distributed capacitance upto circuit breaker between phase and neutral in 0.03 uF. Determine (i) peak re-striking voltage across the contacts of the breaker (ii) frequency of oscillationsarrow_forwardA 13.2 kV, 60 Hz, 3-phase synchronous generator is connected in star and its neutral point is earthed while inductance per phase is 0.02 Henry. The generator is connected to a bus bar through a circuit breaker. The distributed capacitance up to circuit breaker between phase and neutral is 0.015 micro Farad. Determine the following: (i) Peak re-striking voltage (in kV) across the contact of circuit breaker; (ii) Frequency of oscillations (in kHz); (iii) Time to occurs first peak re-striking voltage (in micro second) and (iv) The average rate of rise of re-striking voltage (in mega volts per second)arrow_forwardProblem #2: A transformer is fed from a generator via a 5-cycle breaker. Generator reactance are: X"=18%, X'=25%, Xe=120%. A three-phase fault occurs at the load side of the breaker when the transformer was unloaded. Find: A)The sustained short circuit current in the breaker. B) Initial symmetrical rms current in the breaker. C) Maximum dc short circuit component in the breaker.arrow_forward
- Describe the effects of harmonics on power distribution system.arrow_forwardFull calculation with any assumption needed. All sub questions please as it is all related.arrow_forwardA 12 MVA, 132/6.6 kV, transformer having a reactance of 0.15 pu is fed from an infinite bus. The transformer feeds two motor each 6 MVA, 6.6 kV. Each motors has a transient reactance of 0.14 pu and a subtransient reactance of 0.30 pu based on its own rating. A three phase balanced fault occurs at the terminals of one motor as shown in the figure below. Find the subtransient fault current and subtransient current in breaker. M1) 132/6.6 KV СВ 38 CB Infinite Bus M2 Faultarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning

Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning