An inner-city electric bus with 7,200kg weight and average speed of 72 km/hour operates using a hybrid power source of lithium-ion battery pack and a bank of super capacitor. equipped with a lithium battery pack and a bank of supercapacitor. The energy content of the supercapacitor bank is twice the regenerative breaking energy of the electric bus at average speed. The electric bus commutes 490 km per charged battery and consumes 400 Wh/km.
- Design the supercapacitor bank to provide 100V output, based on supercapacitor cells with 3600F capacitance and 2V.
- Calculate the energy density of the supercapacitor at the cell level, assume cells with 10cm diameter and 15 cm height.
3. Design the battery pack for the electric bus by assuming that the energy of regenerative breaking will not be used for commuting but used to run the vehicle’s accessories. The unit cell of the battery pack is a lithium-ion cell with 3.92V and 20Ah capacity. The battery pack output voltage is 490V.
4..Calculate the energy density of the battery pack, assuming closed-pack arrangement of the prismatic unit cells. Dimensions of the unit cell are 15cm width, 25cm length and 0.5cm thickness.

Step by stepSolved in 2 steps with 1 images

- A 500 MVA synchronous machine has H, = 5.6 MJ/MVA and a 1200 MVA machine has H₂ = 2.0 MJ/MVA. The two machines operate in parallel in a power station. What is the equivalent. H constant for the two, relative to a 100 MVA base?arrow_forwardA generator operating at 50 Hz delivers 1 p.u. power to an infinite bus through a transmission circuit in which resistance is ignored. A fault takes place reducing the maximum power transferable to 0.5 p.u. Where as before the fault, this power was 2.5 p.u. and after the clearance of the fault, it is 2 p.u. The value of 8 is maxarrow_forwardA steam power station of (3* 1.5) MW has an overall efficiency of 32% If the fuel bir has an calorific value of 7500 calorific/kg. With neglect the transmission line losses.Find the fuel consumption for one day if the station supply a daily load his demand is as follow- From From 6pm to 9p.m to Time From midnight From From 5a.m.to 11am to to Sam 11am 6p.m 9p.m midnight Load(kw) 300 1400 900 1800 600arrow_forward
- 8. a) Inductors_________ oppose a change of current.a) always b) sometimes c) never d) all of the above B) What is the direction of a self-induced emf in relation to any change in current? a) . the same direction as the current flow that caused itb) the opposite direction as the current flow that caused it c) may laemettherlalgr "b" d) neither a nor b C). Hysteresis loss is caused by _________a) low voltage DC. b) poorly insulated conductors c) molecular friction d) none of the abovearrow_forwardI need the correct expert solutionarrow_forwardThe maximum demand of a power station is 110 MW. It generates 105 x 10 units during the day. The station has three units of 40 MW and another unit of 40 MW as spare. The running hours of the unit are as follows. The first unit of 40 MW runs for 24 hours. Another unit of 40 MW runs for 14 hours. A third unit of 40 MW runs for 4 hours. So Find (1) daily load factor (2) plant capacity factor (3) utilization factor and (4) plant use factor.arrow_forward
- Please assist with this question with details on how to do it. Thank you.....arrow_forwardA wind energy system has been designed for 20 years of operation. The designed system has a wind turbine of power 600 kW which costs is $450,000. Estimate the Levelized cost of electricity generated by this wind energy system. (Capacity factor: 28.54%)arrow_forwardTOPIC: Power Systems, Power Plants & IlluminationINSTRUCTIONS:- Answer in this format: Given, Illustration, Required Conversion, Solution, Final Answer.- Step-by-step solution, do not skip even simple calculations to avoid confusion.- If answered in written form, make sure it is readable.PROBLEM: A generating station has two 50 MW units each running for 8,500 hours in a year and one 30 MW unit running for 1,250 hours in one year. The station output is 650 x 106 kWh per year. Calculate the utilization factor. 0.732 0.653 0.811 0.795arrow_forward
- In a string of three identical suspension insulator units supporting transmission line conductor.if the self capacitance of each unit is debited as C farads, The capacitance of each connector pin to ground can be taken as 0.1C farad's. If the maximum permissible voltage per unit is given as 20 kva then calculate A.maximum safe working voltage B.string efficiencyarrow_forwardFor the cct. Shown below calculate (for charging phase and discharging phase) (T) Write the equation of Vc Write the equation of ic Write the equation of VR For charging phase plot (on a graph paper) i. Vc ii. ic iii. VR iv. E 1 +27, 2 w RKarrow_forwardThree phase Bridge rectifier operated from a 380V, 50Hz source throughout three-phase Y/Y connected transformer with ration 2:1. The load current has continuous character with negligible ripples and average thyristor current of 15A. The circuit inductance per phase is 1.2mH. The rectified voltage due to overlapping angle is 90 % of that voltage when this angle is neglected. 1- How much will the voltage drop be due to circuit inductance * 2- How much will the dc average voltage Vdc(alpha) be. 3- How much will the firing angle be ? 4- The overlapping angle. 5- How much is the percentage change of the output dc power if the thyristors T2, T4 and T6 are replaced by three diodes D2, D4, D6. 6- How much will be the maximum RMS phase current for the mentioned in previous task circuit ( semi-converter). 7- If an additional of 1 mH inductances are added to the existing inductances in the phases , how much will the overlapping angle be. The dc load current is kept constant & the…arrow_forward
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning