Introduction to Chemical Engineering Thermodynamics
8th Edition
ISBN: 9781259696527
Author: J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher: McGraw-Hill Education
expand_more
expand_more
format_list_bulleted
Question
An adiabatic compressor with 65% efficiency is fed with 25kg/sec of saturated steam at 200kPa. The steam at the exit of the compressor is 1000kPa.
1) What is the state and quality of the steam at the outlet?
2) What is the power requirement for the compressor?
3) What is the enthalpy and the temperature of the steam at the outlet?
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 8 steps with 10 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, chemical-engineering and related others by exploring similar questions and additional content below.Similar questions
- 4.21.* A steady-flow 100% efficient water power plant has the following inlet and outlet conditions: Pressure, P, psig Elevation, z, ft Velocity, V, ft/s Temperature, T, °F Inlet 0 75 400 70.0 Outlet 0 0 50 70.1 The plant is adiabatic. How much work does it deliver per lbm of fluid flowing through?arrow_forward8=1000kg/m3 Poo 1.02.10 u 2) Poo D, = 5cm DI D2 : D. = 3 chm Um iL= 30m D, : inner diameter of outer concentric cylinder (pipe) Dz : outer of inner -11- -11-arrow_forward4.3. Steam flows steadily through an adiabatic turbine. The inlet conditions of the steam are 4 MPa, 500 °C, and 80 m/s, and the exit conditions are 30 kPa, 92 percent quality, and 50 m/s. The mass flow rate of the steam is 12 kg/s. Determine (a) the change in kinetic energy, (b) the power output, and (c) the turbine inlet area. P = 4 MPa T, = 500°C V1 = 80 m/s Steam m = 12 kg/s W. out P2 = 30 kPa X2 = 0.92 V2 = 50 m/sarrow_forward
- Consider a refrigeration system based on an ideal vapor-compression cycle using R-134a as the refrigerant. It operates between 0.7 MPa and 0.12 MPa with a flow rate of 0.5 mol/s. Calculate the following: (a) the rate of heat removal from the refrigerated unit (b) the power input needed to the compressor (c) the COP The properties of R-134a can be found at http://webbook.nist.gov/chemistry/fluid/.arrow_forwardThermal systems problem: Assume that nitrogen is available in a storage tank at 2 MPa and 210 K. On the following chart, show the path for the following scenarios. a) An expansion valve is connected to this tank that drops the fluid (i.e., nitrogen) pressure at its outlet to one atmosphere. b) A compressor is connected to this tank that raises the fluid pressure at its outlet to 10 MPa. c) A turbine is connected to this tank that drops the fluid pressure at its outlet to one atmospheric pressure. d) A heat exchanger is connected to this tank that raises the fluid temperature to 330K at its outlet. e) A heat exchanger is connected to this tank that drops the fluid temperature to 135K at its outlet. f) Show the process for the fluid to change its state from 2 MPa and 210 K to 14 MPa and 240 K. Identify the required equipment. g) If a coolant at 150 K is available, is it possible to change the state of nitrogen from 2 MPa and 210 K to saturated liquid at atmospheric pressure? If…arrow_forwardi need the answer quicklyarrow_forward
- 8arrow_forwardWater vapor expands at a turbine at a speed of 1350 kg / s, the inlet conditions are 8MPA and 400C, the outlet conditions are 500KPa and 250C, the turbine does 200kW work. Neglect changes in kinetic and potential energy. a) Write and simplify the equation that applies to this system. b) What are the specific enthalpies of the input and output current? c) What is the heat transfer in Kw? d) What is the specific volume and volumetric flow at the inlet? e) What is the specific volume and the volumetric flow at the outletarrow_forwardSeparate streams of air and water flow through the compressor and heat exchanger arrangement shown below. Steady-state operating data is provided in the figure. Heat transfer with the environment can be neglected, as can all potential and kinetic energy effects. Air is modeled as an ideal gas. Determine: (a) the total power required by both compressors, in kW. (b) the mass flow rate of the water, in kg / s.arrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Introduction to Chemical Engineering Thermodynami...Chemical EngineeringISBN:9781259696527Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark SwihartPublisher:McGraw-Hill EducationElementary Principles of Chemical Processes, Bind...Chemical EngineeringISBN:9781118431221Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. BullardPublisher:WILEYElements of Chemical Reaction Engineering (5th Ed...Chemical EngineeringISBN:9780133887518Author:H. Scott FoglerPublisher:Prentice Hall
- Industrial Plastics: Theory and ApplicationsChemical EngineeringISBN:9781285061238Author:Lokensgard, ErikPublisher:Delmar Cengage LearningUnit Operations of Chemical EngineeringChemical EngineeringISBN:9780072848236Author:Warren McCabe, Julian C. Smith, Peter HarriottPublisher:McGraw-Hill Companies, The
Introduction to Chemical Engineering Thermodynami...
Chemical Engineering
ISBN:9781259696527
Author:J.M. Smith Termodinamica en ingenieria quimica, Hendrick C Van Ness, Michael Abbott, Mark Swihart
Publisher:McGraw-Hill Education
Elementary Principles of Chemical Processes, Bind...
Chemical Engineering
ISBN:9781118431221
Author:Richard M. Felder, Ronald W. Rousseau, Lisa G. Bullard
Publisher:WILEY
Elements of Chemical Reaction Engineering (5th Ed...
Chemical Engineering
ISBN:9780133887518
Author:H. Scott Fogler
Publisher:Prentice Hall
Industrial Plastics: Theory and Applications
Chemical Engineering
ISBN:9781285061238
Author:Lokensgard, Erik
Publisher:Delmar Cengage Learning
Unit Operations of Chemical Engineering
Chemical Engineering
ISBN:9780072848236
Author:Warren McCabe, Julian C. Smith, Peter Harriott
Publisher:McGraw-Hill Companies, The