
Structural Analysis
6th Edition
ISBN: 9781337630931
Author: KASSIMALI, Aslam.
Publisher: Cengage,
expand_more
expand_more
format_list_bulleted
Question
QUESTION:
A W10x112 column rest on a base plate and on a 400 mm x 400 mm concrete pedestal. The pedestal and
base plate are of the same dimensions. Yield strength of steel Fy = 248MPa, effective length of column Le=
W/4 m. Concrete strength fc = W MPa. Use ASD. (Hint Le = kL)
a.What is the allowable axial capacity of the column in kN?
b.What is the allowable bearing capacity of the pedestal in kN?
C.What is the minimum required thickness of the base plate rounded off to nearest safe 5 mm?
Reference for datas
W= 25 mm , 25 MPa
W/2 = 12.5 m
W/4 =6.25m
X=475 KN
Y= 155 KN, 155 KPa, 175 mm
Z=60
×+Z=535mm
Expert Solution

This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps with 2 images

Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.Similar questions
- 1/ Calculate maximum deflection of the beams (This was solve it) 2/ Check the suitability of the section assuming the code limitation of L/240. 3/ If maximum deflection doesn’t meet the code requirement, propose your solutionarrow_forwardA reinforced concrete cantilever beam is shown below. The beam cross section is a rectangle, 12 inches deep by 18 inches wide. Material properties are: - Concrete weight: wt = 150 pcf - Concrete compressive strength: f'c = 4000 psi - Concrete tensile strength: f't = 400 psi - Steel tensile strength: fy = 60 ksi - Stirrup consists of #4 bar - Beam is not exposed to weather or in contact with soil. Determine if the beam will crack under its own weight, if its self-weight is 250lb/ft. 10 ft -18" BEAM SECTION beam will crack beam will not crack unknown, not enough information to calculatearrow_forwardShow full solutionarrow_forward
- If column AB is made from high strength pre-castconcrete and reinforced with four 20 mm diameter A-36steel rods, determine the maximum allowable floorloadings P. The allowable normal stress for the highstrength concrete and the steel are (ϭallow)con = 18 MPaand (ϭallow)st= 170 MPa, respectively.arrow_forwardThe answer is close to 60 Ksi. I need help showing the work to get the answer . Please include units. Thanksarrow_forward
arrow_back_ios
arrow_forward_ios
Recommended textbooks for you
- Structural Analysis (10th Edition)Civil EngineeringISBN:9780134610672Author:Russell C. HibbelerPublisher:PEARSONPrinciples of Foundation Engineering (MindTap Cou...Civil EngineeringISBN:9781337705028Author:Braja M. Das, Nagaratnam SivakuganPublisher:Cengage Learning
- Fundamentals of Structural AnalysisCivil EngineeringISBN:9780073398006Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel LanningPublisher:McGraw-Hill EducationTraffic and Highway EngineeringCivil EngineeringISBN:9781305156241Author:Garber, Nicholas J.Publisher:Cengage Learning


Structural Analysis (10th Edition)
Civil Engineering
ISBN:9780134610672
Author:Russell C. Hibbeler
Publisher:PEARSON

Principles of Foundation Engineering (MindTap Cou...
Civil Engineering
ISBN:9781337705028
Author:Braja M. Das, Nagaratnam Sivakugan
Publisher:Cengage Learning

Fundamentals of Structural Analysis
Civil Engineering
ISBN:9780073398006
Author:Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:McGraw-Hill Education


Traffic and Highway Engineering
Civil Engineering
ISBN:9781305156241
Author:Garber, Nicholas J.
Publisher:Cengage Learning