A utility company is running three generators (where the system demand for the current time period is 650 MW), and has the following operating costs in dollars per hour and corresponding generation range (noted below): 2$ C, (p1) = 200 + 20p, + 0.01p?-, 200MW < P1 < 400MW C2(p2) = 150 + 30pz + 0.02p3, 100MW < p2 S 300MW $ C3 (P3) = 100 + 45p3 + 0.05p3 50MW < P3 < 200MW Determine: 1) The economic dispatch of generators during this hour 2) The total operating cost during this hour 3) The marginal electricity cost of the system 4) At a certain time period the system price is $55 per MWh ($/MWh), what is the system demand during this time period?

Power System Analysis and Design (MindTap Course List)
6th Edition
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Chapter2: Fundamentals
Section: Chapter Questions
Problem 2.16P: A single-phase, 120V(rms),60Hz source supplies power to a series R-L circuit consisting of R=10 and...
icon
Related questions
Question
100%
A utility company is running three generators (where the system demand for the current time.
period is 650 MW), and has the following operating costs in dollars per hour and corresponding
generation range (noted below):
$
C (P1) = 200 + 20p1 + 0.01p?,
200MW < p1 < 400MW
$
C2(p2) = 150 + 30p2 + 0.02p3
h
100MW < P2 < 300MW
$
C; (p3) = 100 + 45p3 + 0.05p
50MW < P3 S 200MW
%3D
Determine:
1) The economic dispatch of generators during this hour
2) The total operating cost during this hour
3) The marginal electricity cost of the system
4) At a certain time period the system price is $55 per MWh ($/MWh), what is the system
demand during this time period?
Transcribed Image Text:A utility company is running three generators (where the system demand for the current time. period is 650 MW), and has the following operating costs in dollars per hour and corresponding generation range (noted below): $ C (P1) = 200 + 20p1 + 0.01p?, 200MW < p1 < 400MW $ C2(p2) = 150 + 30p2 + 0.02p3 h 100MW < P2 < 300MW $ C; (p3) = 100 + 45p3 + 0.05p 50MW < P3 S 200MW %3D Determine: 1) The economic dispatch of generators during this hour 2) The total operating cost during this hour 3) The marginal electricity cost of the system 4) At a certain time period the system price is $55 per MWh ($/MWh), what is the system demand during this time period?
Expert Solution
trending now

Trending now

This is a popular solution!

steps

Step by step

Solved in 4 steps with 4 images

Blurred answer
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning