Question
A synchronous generator has 4 poles and a synchronous reactance of 5 ohms. The operating frequency is 60 Hz. The stator windings are connected in Y and the voltage between the lines is Vl= 15 kV. The generator line current is 1 kA with a power factor of 0.9 (lagging). Find:
a) The amplitude of the excitation voltage (induced voltage Eaf. ).
b) The actual power delivered by the generator.
c) The reactive power supplied by the generator.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
Step by stepSolved in 5 steps with 13 images
Knowledge Booster
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.Similar questions
- In alternator, the diameter of salient pole rotor is...arrow_forwardA 4-pole lap winding generator with 16 slot, 42 conductor per slot, 480v runs at 1800rpm. Find the flux produced per polearrow_forwardA 50-MVA, 30-kV, three-phase synchronous generator has a synchronous reactance of 8 Ohms/phase and negligible armature resistance. The generator is delivering 50 MVA at 0.8 pf leading to an infinite bus at the rated voltage. Determine the excitation per phase E and the power angle &. Select one: O a. E = 22.78 KV and 8= 15.67 deg. O b. E = 14.115 KV and 8= 25.85 deg. O c. None of these O d. E = 13.96KV and 8= 29.74 deg. O e. E = 27.47KV and 8= 22.84 deg. Impedances are marked in perunit on a 100MVA, 100 KV base. The load at bus 2 is S2= 16MW - 132 MVAR, and the load at EN ? 1:4 4/1- TOSHIBAarrow_forward
- In a Three-phase alternator, a given field current produces an armature current of 250 A on short-circuit and a generated e.m.f. of 1500 V on open-circuit. Calculate the terminal p.d. when a load of 250 A at 6.6 kV and 0.8 p.f. lagging is switched off. Calculate also the regulation of the alternator at the given load. Subject: Electrical engineeringarrow_forwardA lap connected 6 pole DC generator has an armature conductors of 500 and is driven at 600 rpm. If the flux per pole is 15 mWb, then the generated e.m.f is,؟ 250 V 225 V 75 V 100 Varrow_forwardthe frequency of the induction generator on the rot ratori 9- Explain how does a synchronous generator work. Support your answer with drawing. 10-Draw the synchronous generator phasor diagram forimir tead power factorarrow_forward
- An 135-pole d.c. shunt generator with wave wound armature having 620 conductors, has to supply a load of 170 lamps each of 135W at 235 v. The flux per pole is 22 mWb and Ra = 2 ohms, Rsh=70ohms. What will be the load current and e.m.f generated. Consider brush drop of 1.6v/brush. Load Current Generated EMEarrow_forward10- A long shunt compound generator delivers a current of 10A at 200V and has a series field resistance and shunt field resistance of 1 ohm and 200 ohms respectively. Then series field current is a. 10A b. 9A c. 1A d. 2Aarrow_forwardC 4 Pole generator has a lap wound armature with 30 conductor per slot. The flux per pole is 30mWb and the speed of the generator is 960rpm. Find the total number of slots to generate an EMF of 316.8V.arrow_forward
- Flux is exactly proportional to L2 times field current in a d.c generator. The generator operates at a speed of 200 revolutions per minute and has a flux of 62 mWb.f per pole. The generator is lap wound with 1500 conductors in series; determine the e.m.f. produced. If the winding is wave wound, calculate the change in excitation current required to get the same voltage as previously stated. The machine has six poles.arrow_forward2. A four-pole three-phase 50 hertz, star connected AC generator has 12 stator slots. There are 4 conductors per slot and a sinusoidally distributed flux per pole of 36mWb. Find the terminal voltage on open circuit. If the coil span factor is 0.85 lagging.arrow_forwardDuestion. Explain sompound DC :- describe its generator types of also and terminal characteristics compound DC. generatorarrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Introductory Circuit Analysis (13th Edition)Electrical EngineeringISBN:9780133923605Author:Robert L. BoylestadPublisher:PEARSONDelmar's Standard Textbook Of ElectricityElectrical EngineeringISBN:9781337900348Author:Stephen L. HermanPublisher:Cengage LearningProgrammable Logic ControllersElectrical EngineeringISBN:9780073373843Author:Frank D. PetruzellaPublisher:McGraw-Hill Education
- Fundamentals of Electric CircuitsElectrical EngineeringISBN:9780078028229Author:Charles K Alexander, Matthew SadikuPublisher:McGraw-Hill EducationElectric Circuits. (11th Edition)Electrical EngineeringISBN:9780134746968Author:James W. Nilsson, Susan RiedelPublisher:PEARSONEngineering ElectromagneticsElectrical EngineeringISBN:9780078028151Author:Hayt, William H. (william Hart), Jr, BUCK, John A.Publisher:Mcgraw-hill Education,
Introductory Circuit Analysis (13th Edition)
Electrical Engineering
ISBN:9780133923605
Author:Robert L. Boylestad
Publisher:PEARSON
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Cengage Learning
Programmable Logic Controllers
Electrical Engineering
ISBN:9780073373843
Author:Frank D. Petruzella
Publisher:McGraw-Hill Education
Fundamentals of Electric Circuits
Electrical Engineering
ISBN:9780078028229
Author:Charles K Alexander, Matthew Sadiku
Publisher:McGraw-Hill Education
Electric Circuits. (11th Edition)
Electrical Engineering
ISBN:9780134746968
Author:James W. Nilsson, Susan Riedel
Publisher:PEARSON
Engineering Electromagnetics
Electrical Engineering
ISBN:9780078028151
Author:Hayt, William H. (william Hart), Jr, BUCK, John A.
Publisher:Mcgraw-hill Education,