3.7 A single conductor power cable has a conductor of No. 2 solid copper (radius = 0.328 cm). Paper insulation separating the conductor from the concentric lead sheath has a thickness of 2.5 mm and a relative permittivity of 3.8. The thickness of the lead sheath is 2 mm. Find the capacitive reactance per kilometre between the inner çonductor and the lead sheath.
Expert Solution
This question has been solved!
Explore an expertly crafted, step-by-step solution for a thorough understanding of key concepts.
This is a popular solution
Trending nowThis is a popular solution!
Step by stepSolved in 2 steps
Knowledge Booster
Similar questions
- Determine the GMR of each of the unconventional stranded conductors shown in Figure 4.30. All strands have the same radius r.arrow_forwardA single core lead covered cable is to be designed for 68 kV(peak value) toearth. Its conductor diameter is 2 cm and its three insulating materials havepermittivities of 5, 4 and 3 respectively with the corresponding maximumsafe working stress of 38 kV/cm (r.m.s), 26 kV/cm (r.m.s) and 20 kV/cm(r.m.s) respectively. Find the minimum diameter of lead sheath.arrow_forwardA 33 kV single core cable has a conductor diameter of 1 cm and a sheath of inside diameter 4 cm. Find the maximum and minimum stress in the insulation.arrow_forward
- GMR calculatearrow_forwardPlease solve questions c f and g in detail step by step and show calculations preferably handwritten solution thank you very mucharrow_forwardThe diameter of an ACSR conductor is 1.1116 inches. The steel core has strands of diameters of 0.1291 inches each. If 54 Aluminum strands have the diameters of 0.1351 inches each, the number of Steel strands is: O A. 15 O B. None of choices are correct O C. 19 O D.7 O E. 27arrow_forward
- Assume that a single-conductor belted cable has a conductor diameterof 0.681 in., inside diameter of sheath of 1.7025 in., and a length of8000 ft. The cable is to be operated at 12.47 kV. The dielectricconstant is 4.5, and the power factor of the dielectric at a ratedfrequency and temperature is 0.05. Calculate the following:(a) Capacitance of cable.(b) Charging current.(c) Dielectric loss of cable.(d) Equivalent resistance of insulation.arrow_forwardA single core 66 kVolts cable has a conductor diameter of 2 cm and a sheath of inside diameter 5.3 cm. The cable has an inner layer of 1 cm thick of rubber of dielectric constant of 4.5 and the rest impregnated paper of dielectric constant 3.6. Find the maximum stress in the rubber and in the paper.arrow_forwardDetermine the mutual inductance between a very long straightwire and a conducting circular loop of radius “b” m set up “d” mapart on the same plane as shown figure.Problem:arrow_forward
- The geometric mean radius of a conductor, having four equal strands with each strand of radius 'r', as shown in the figure below, is rarrow_forwardAmagnetic field is being generated by a current of 2.0A flowing through 180 turns of wire on a core having a reluctance of 210000.0 At/Wb. Determine the flux of the circuit in mWb.arrow_forwardH. W.: The cost of a 2-core feeder cable, including installation is (90 a + 20) per meter and the interest and depreciation charges are 10 per cent. The cable is 2 km in length and cost of energy is 4% per unit. The maximum current in the feeder is 250 A and the demand is such that the current copper loss is equivalent to what would be produced by the full flowing for 6 months. If the resistance of a conductor of 1 square cm and 1 km length is 0.173 Q, calculate the most economical cross-sectional area.arrow_forward
arrow_back_ios
SEE MORE QUESTIONS
arrow_forward_ios
Recommended textbooks for you
- Power System Analysis and Design (MindTap Course ...Electrical EngineeringISBN:9781305632134Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. SarmaPublisher:Cengage Learning
Power System Analysis and Design (MindTap Course ...
Electrical Engineering
ISBN:9781305632134
Author:J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:Cengage Learning