A rotating laser is being used to control the casting of a concrete floor slab. The instrument is set up over a TBM that has a reduced level of 1299.234 mAOD and the projected plane is 1.534 m above this height. The base of the floor slab has a reduced level of 1296.734 mAOD and the slab must be 300 mm thick. What height on a levelling staff must the laser detector be mounted in order to ensure the slab is cast to the correct thickness (please state the value in metres and quote the value to three decimal places)?

Structural Analysis
6th Edition
ISBN:9781337630931
Author:KASSIMALI, Aslam.
Publisher:KASSIMALI, Aslam.
Chapter2: Loads On Structures
Section: Chapter Questions
Problem 1P
icon
Related questions
Question
A rotating laser is being used to control the casting of a concrete floor slab. The instrument is set up over a TBM that has a reduced level of 1299.234 mAOD and the projected plane is 1.534 m above this height. The base of the floor slab has a reduced level of 1296.734 mAOD and the slab must be 300 mm thick. What height on a levelling staff must the laser detector be mounted in order to ensure the slab is cast to the correct thickness (please state the value in metres and quote the value to three decimal places)?
A rotating laser is being used to control the casting of a concrete floor slab. The instrument is set up
over a TBM that has a reduced level of 1299.234 m AOD and the projected plane is 1.534 m above
this height. The base of the floor slab has a reduced level of 1296.734 m AOD and the slab must be
300 mm thick. What height on a levelling staff must the laser detector be mounted in order to
ensure the slab is cast to the correct thickness (please state the value in metres and quote the value
to three decimal places)?
Transcribed Image Text:A rotating laser is being used to control the casting of a concrete floor slab. The instrument is set up over a TBM that has a reduced level of 1299.234 m AOD and the projected plane is 1.534 m above this height. The base of the floor slab has a reduced level of 1296.734 m AOD and the slab must be 300 mm thick. What height on a levelling staff must the laser detector be mounted in order to ensure the slab is cast to the correct thickness (please state the value in metres and quote the value to three decimal places)?
Expert Solution
steps

Step by step

Solved in 3 steps

Blurred answer
Knowledge Booster
Errors in surveying
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, civil-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Structural Analysis
Structural Analysis
Civil Engineering
ISBN:
9781337630931
Author:
KASSIMALI, Aslam.
Publisher:
Cengage,
Structural Analysis (10th Edition)
Structural Analysis (10th Edition)
Civil Engineering
ISBN:
9780134610672
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Principles of Foundation Engineering (MindTap Cou…
Principles of Foundation Engineering (MindTap Cou…
Civil Engineering
ISBN:
9781337705028
Author:
Braja M. Das, Nagaratnam Sivakugan
Publisher:
Cengage Learning
Fundamentals of Structural Analysis
Fundamentals of Structural Analysis
Civil Engineering
ISBN:
9780073398006
Author:
Kenneth M. Leet Emeritus, Chia-Ming Uang, Joel Lanning
Publisher:
McGraw-Hill Education
Sustainable Energy
Sustainable Energy
Civil Engineering
ISBN:
9781337551663
Author:
DUNLAP, Richard A.
Publisher:
Cengage,
Traffic and Highway Engineering
Traffic and Highway Engineering
Civil Engineering
ISBN:
9781305156241
Author:
Garber, Nicholas J.
Publisher:
Cengage Learning