A resistance thermometer (RTD) is used to measure the temperature of fluid in a container. The RTD resistance changes with temperature according to the following equation: R₁ = R₁(1 + aT), where a = 0.03(°C)-¹, R₁, is the RTD's nominal resistance that equals 30002, and T is the temperature in °C. The RTD forms one arm of a bridge circuit as shown in the figure. The components of the circuit have the following values: R₁-3002; R₂-35002; R3-350052. The resistance of the measuring voltmeter is neglected. Answer the following: A. If the bridge excitation voltage (V) is 15V, calculate the bridge sensitivity in units of volts/ohm. B. Calculate the temperature measurement sensitivity in volts/ °C R %₂ Vi

Delmar's Standard Textbook Of Electricity
7th Edition
ISBN:9781337900348
Author:Stephen L. Herman
Publisher:Stephen L. Herman
Chapter19: Capacitors
Section: Chapter Questions
Problem 2PA: You are an electrician working in an industrial plant. You discover that the problem with a certain...
icon
Related questions
Question

I need a step by step answer please :)

A resistance thermometer (RTD) is used to measure the
temperature of fluid in a container. The RTD resistance
changes with temperature according to the following equation:
|R₁ = Ru(1 + aT), where a = 0.03 (°C)-¹, R₁, is the RTD's
nominal resistance that equals 30092, and T is the temperature
in °C. The RTD forms one arm of a bridge circuit as shown in
the figure. The components of the circuit have the following
values: R₁-3002; R₂-35002; R3-350092. The resistance of
the measuring voltmeter is neglected. Answer the following:
A. If the bridge excitation voltage (V) is 15V, calculate
the bridge sensitivity in units of volts/ohm.
B. Calculate the temperature measurement sensitivity in
volts/ °C
R
V₂
Transcribed Image Text:A resistance thermometer (RTD) is used to measure the temperature of fluid in a container. The RTD resistance changes with temperature according to the following equation: |R₁ = Ru(1 + aT), where a = 0.03 (°C)-¹, R₁, is the RTD's nominal resistance that equals 30092, and T is the temperature in °C. The RTD forms one arm of a bridge circuit as shown in the figure. The components of the circuit have the following values: R₁-3002; R₂-35002; R3-350092. The resistance of the measuring voltmeter is neglected. Answer the following: A. If the bridge excitation voltage (V) is 15V, calculate the bridge sensitivity in units of volts/ohm. B. Calculate the temperature measurement sensitivity in volts/ °C R V₂
Expert Solution
steps

Step by step

Solved in 3 steps with 11 images

Blurred answer
Knowledge Booster
Mathematical Modeling of Mechanical System
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, electrical-engineering and related others by exploring similar questions and additional content below.
Similar questions
  • SEE MORE QUESTIONS
Recommended textbooks for you
Delmar's Standard Textbook Of Electricity
Delmar's Standard Textbook Of Electricity
Electrical Engineering
ISBN:
9781337900348
Author:
Stephen L. Herman
Publisher:
Cengage Learning
Power System Analysis and Design (MindTap Course …
Power System Analysis and Design (MindTap Course …
Electrical Engineering
ISBN:
9781305632134
Author:
J. Duncan Glover, Thomas Overbye, Mulukutla S. Sarma
Publisher:
Cengage Learning
Electricity for Refrigeration, Heating, and Air C…
Electricity for Refrigeration, Heating, and Air C…
Mechanical Engineering
ISBN:
9781337399128
Author:
Russell E. Smith
Publisher:
Cengage Learning