a refrigerant R-22 vapour compression system includes a liquid to suction heat exchanger in the system. The heat exchanger warms saturated vapour coming from evaporator from (-10 °C) to 5 °C with liquid which comes from the condenser at 30°C. the compression are isentropic in both cases below. A - calculate the COP of the system without the heat exchanger but with condensing temperature at 30°C and evaporator temperature of (-10°C)(5.46) b- calculate the COP with the heat exchanger (5.37) c- if the compressor is capable of pumping 12 lit/s measured at the compressor suction, what is the refrigeration capacity of the system without heat exchanger and with heat Crchanger(30 3KW. 29.9kW)

Elements Of Electromagnetics
7th Edition
ISBN:9780190698614
Author:Sadiku, Matthew N. O.
Publisher:Sadiku, Matthew N. O.
ChapterMA: Math Assessment
Section: Chapter Questions
Problem 1.1MA
icon
Related questions
Question
I want the solution very quickly within 15 minutes
5.
a refrigerant R-22 vapour compression system includes a liquid to suction heat
exchanger in the system. The heat exchanger warms saturated vapour coming
from evaporator from (-10 °C) to 5 °C with liquid which comes from the
condenser at 30°C. the compression are isentropic in both cases below. A
calculate the COP of the system without the heat exchanger but with
condensing temperature at 30°C and evaporator temperature of (-10°C)(5.46)
b- calculate the COP with the heat exchanger (5.37) c- if the compressor is
capable of pumping 12 lit/s measured at the compressor suction, what is the
refrigeration capacity of the system without heat exchanger and with heat
exchanger(30.3kW, 29.9kW)
Transcribed Image Text:5. a refrigerant R-22 vapour compression system includes a liquid to suction heat exchanger in the system. The heat exchanger warms saturated vapour coming from evaporator from (-10 °C) to 5 °C with liquid which comes from the condenser at 30°C. the compression are isentropic in both cases below. A calculate the COP of the system without the heat exchanger but with condensing temperature at 30°C and evaporator temperature of (-10°C)(5.46) b- calculate the COP with the heat exchanger (5.37) c- if the compressor is capable of pumping 12 lit/s measured at the compressor suction, what is the refrigeration capacity of the system without heat exchanger and with heat exchanger(30.3kW, 29.9kW)
Expert Solution
steps

Step by step

Solved in 4 steps with 1 images

Blurred answer
Recommended textbooks for you
Elements Of Electromagnetics
Elements Of Electromagnetics
Mechanical Engineering
ISBN:
9780190698614
Author:
Sadiku, Matthew N. O.
Publisher:
Oxford University Press
Mechanics of Materials (10th Edition)
Mechanics of Materials (10th Edition)
Mechanical Engineering
ISBN:
9780134319650
Author:
Russell C. Hibbeler
Publisher:
PEARSON
Thermodynamics: An Engineering Approach
Thermodynamics: An Engineering Approach
Mechanical Engineering
ISBN:
9781259822674
Author:
Yunus A. Cengel Dr., Michael A. Boles
Publisher:
McGraw-Hill Education
Control Systems Engineering
Control Systems Engineering
Mechanical Engineering
ISBN:
9781118170519
Author:
Norman S. Nise
Publisher:
WILEY
Mechanics of Materials (MindTap Course List)
Mechanics of Materials (MindTap Course List)
Mechanical Engineering
ISBN:
9781337093347
Author:
Barry J. Goodno, James M. Gere
Publisher:
Cengage Learning
Engineering Mechanics: Statics
Engineering Mechanics: Statics
Mechanical Engineering
ISBN:
9781118807330
Author:
James L. Meriam, L. G. Kraige, J. N. Bolton
Publisher:
WILEY