A radiator heat exchanger is to be designed for the following specifications. Hot gas at 1145°C, Cold gas temperature 45°C, Unit surface conductance on the hot side, 230 W/m2-K, Unit surface conductance on the cold side 290 W/m2-K, Thermal conductivity of the metal wall 1115 W/m-K. Find the maximum thickness (in mm) of the metal wall between the hot gas and the cold gas so that the maximum temperature of the wall does not exceed 545°C.
Heat Exchangers
Heat exchangers are the types of equipment that are primarily employed to transfer the thermal energy from one fluid to another, provided that one of the fluids should be at a higher thermal energy content than the other fluid.
Heat Exchanger
The heat exchanger is a combination of two words ''Heat'' and ''Exchanger''. It is a mechanical device that is used to exchange heat energy between two fluids.
A radiator heat exchanger is to be designed for the following specifications. Hot gas at 1145°C, Cold gas temperature 45°C, Unit surface conductance on the hot side, 230 W/m2-K, Unit surface conductance on the cold side 290 W/m2-K, Thermal conductivity of the metal wall 1115 W/m-K. Find the maximum thickness (in mm) of the metal wall between the hot gas and the cold gas so that the maximum temperature of the wall does not exceed 545°C.