A house is equipped with an air conditioner that uses refrigerant-134a as the working fluid, as shown in Figure 1. The air conditioner is used to keep the house at 25°C by rejecting heat the waste heat to outdoor at 37°C. The house gains heat through the walls and the windows at a rate of 300 kJ/min while the heat generated with the computer, TV and lights amounts to 900 W. The refrigerant enters the compressor at 500 kPa as a saturated vapour with a rate of 150 L/min and leaves at 1200 kPa and 50°C. Determine: i. actual COP, il. the maximum COP, and iii. the minimum volume flow rate (in L/min) of the refrigerant at the compressor inlet for the same compressor inlet and exit conditions. QH Expansion valve Condenser Evaporator •Q₁ 1.2 MPa 50°C Win Compressor 500 KPa Saturated vapor 500 KPa

Refrigeration and Air Conditioning Technology (MindTap Course List)
8th Edition
ISBN:9781305578296
Author:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Publisher:John Tomczyk, Eugene Silberstein, Bill Whitman, Bill Johnson
Chapter44: Geothermal Heat Pumps
Section: Chapter Questions
Problem 2RQ: An important factor (or factors) involving water quality with regard to open-loop heat pump systems...
icon
Related questions
Question

7

b) A house is equipped with an air conditioner that uses refrigerant-134a as the working
fluid, as shown in Figure 1. The air conditioner is used to keep the house at 25°C by
rejecting heat the waste heat to outdoor at 37°C. The house gains heat through the walls
and the windows at a rate of 300 kJ/min while the heat generated with the computer, TV
and lights amounts to 900 W. The refrigerant enters the compressor at 500 kPa as a
saturated vapour with a rate of 150 L/min and leaves at 1200 kPa and 50°C. Determine:
I. actual COP.
ii. the maximum COP, and
iii. the minimum volume flow rate (in L/min) of the refrigerant at the compressor
inlet for the same compressor inlet and exit conditions.
QH
Expansion
valve
Condenser
1.2 MPa
50°C
Evaporator
•Q₁
Figure 1: Air-conditioner Cycle
Win
Compressor
500 KPa
Saturated vapor
500 KPa
Transcribed Image Text:b) A house is equipped with an air conditioner that uses refrigerant-134a as the working fluid, as shown in Figure 1. The air conditioner is used to keep the house at 25°C by rejecting heat the waste heat to outdoor at 37°C. The house gains heat through the walls and the windows at a rate of 300 kJ/min while the heat generated with the computer, TV and lights amounts to 900 W. The refrigerant enters the compressor at 500 kPa as a saturated vapour with a rate of 150 L/min and leaves at 1200 kPa and 50°C. Determine: I. actual COP. ii. the maximum COP, and iii. the minimum volume flow rate (in L/min) of the refrigerant at the compressor inlet for the same compressor inlet and exit conditions. QH Expansion valve Condenser 1.2 MPa 50°C Evaporator •Q₁ Figure 1: Air-conditioner Cycle Win Compressor 500 KPa Saturated vapor 500 KPa
Expert Solution
steps

Step by step

Solved in 2 steps with 2 images

Blurred answer
Knowledge Booster
Basic Mechanics Problems
Learn more about
Need a deep-dive on the concept behind this application? Look no further. Learn more about this topic, mechanical-engineering and related others by exploring similar questions and additional content below.